Last modified by Admin on 2025/02/21 14:51

From version 9.46
edited by Admin
on 2025/01/30 15:17
Change comment: There is no comment for this version
To version 9.47
edited by Admin
on 2025/01/30 15:18
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -45,9 +45,9 @@
45 45  |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**
46 46  |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3**
47 47  |Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 -|Balancing 1 |BA1|balancing the first series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
49 -|Balancing 2 |BA2|balancing the second series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
50 -|Cell analysis|CEA| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
49 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
50 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
51 51  |Charging current present |CCP|the presence of the charging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
52 52  |Charging |CH|state of the charging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
53 53  |Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
... ... @@ -60,7 +60,7 @@
60 60  |Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
61 61  |Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
62 62  |High charging current |HCC|charging current is high;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
63 -|Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
63 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
64 64  |Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
65 65  |Main contactor |MCO|state of the main contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
66 66  |Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
... ... @@ -68,13 +68,13 @@
68 68  |Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
69 69  |Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
70 70  |Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
71 -|Service reset|SR| |Yes| |Yes|(% style="width:140px" %) |(% style="width:142px" %)
72 72  | | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
73 73  | | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
74 74  | | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
74 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
75 75  
76 76  (% class="wikigeneratedid" %)
77 -Here is the list of indicative internal states that cannot be assigned to discrete output or relay.
77 +Here is the list of indicative internal states that are used  that cannot be assigned to discrete output or relay.
78 78  
79 79  (% style="width:1277px" %)
80 80  |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**
... ... @@ -86,7 +86,10 @@
86 86  |Shutdown request (Combilift)|CSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
87 87  |Shutdown request (HYG/Spirit)|HSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
88 88  |Voltage too high for charging|ENV| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
89 -|Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
89 +|Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
90 +|Service reset|SR| |Yes| |Yes|(% style="width:140px" %) |(% style="width:142px" %)
91 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
92 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
90 90  
91 91  === List of errors ===
92 92