Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -30,6 +30,7 @@ 30 30 |Main contactor feedback |MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 31 31 |PCH contactor feedback |PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 32 32 |Power up/down request |PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 33 +|Precharge request|PRE|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %) |(% style="width:137px" %) |(% style="width:137px" %) 33 33 34 34 === List of internal states === 35 35 ... ... @@ -37,8 +37,8 @@ 37 37 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 38 38 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 39 39 |Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 40 -|Balancing 1 |BA1|balancing the first series of cells;| Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)41 -|Balancing 2 |BA2|balancing the second series of cells;| Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)41 +|Balancing 1 |BA1|balancing the first series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 42 +|Balancing 2 |BA2|balancing the second series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 42 42 |Cell analysis|CEA| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %) 43 43 |Charging current present |CCP|the presence of the charging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 44 44 |Charging |CH|state of the charging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -48,9 +48,9 @@ 48 48 |Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 49 |Discharging current present |DCP|the presence of the discharging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 50 |Discharging |DCH|state of the discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 51 -|External 1 |EX1|a signal that activates by the remote request.| Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)52 +|External 1 |EX1|a signal that activates by the remote request.| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 52 52 |Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 -|Heater (AUX)| 54 +|Heater (AUX)|HA| | |Yes| |(% style="width:140px" %) |(% style="width:142px" %) 54 54 |High charging current |HCC|charging current is high;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 55 55 |Init|INI| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %) 56 56 |Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -61,9 +61,9 @@ 61 61 |Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 62 |Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 63 |Service reset|SR| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 64 -|Shutdown request (Combilift)|CSH| |Yes| 65 -|Shutdown request (HYG/Spirit)|HSH| |Yes| 66 -|Voltage too high for charging|ENV| |Yes| 65 +|Shutdown request (Combilift)|CSH| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %) 66 +|Shutdown request (HYG/Spirit)|HSH| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %) 67 +|Voltage too high for charging|ENV| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %) 67 67 68 68 === List of errors === 69 69