... ... @@ -113,11 +113,11 @@ 113 113 |(% style="width:196px" %)Main contactor feedback error |(% style="width:58px" %)MCF|(% style="width:443px" %)the control signals for the main contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 114 114 |(% style="width:196px" %)Contactor feedback error|(% style="width:58px" %)CFE|(% style="width:443px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 115 115 |(% style="width:196px" %)General error|(% style="width:58px" %)GE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 116 -|(% style="width:196px" %)High voltage fault |(% style="width:58px" %)HVF|(% style="width:443px" %) 117 -|(% style="width:196px" %)Power switch error |(% style="width:58px" %)PSE|(% style="width:443px" %) 118 -|(% style="width:196px" %)HVIL error |(% style="width:58px" %)HE|(% style="width:443px" %) 119 -|(% style="width:196px" %)Precharge error |(% style="width:58px" %)PE|(% style="width:443px" %) 120 -|(% style="width:196px" %)Power fault |(% style="width:58px" %)PF|(% style="width:443px" %) 121 -|(% style="width:196px" %)Current limit error |(% style="width:58px" %)CLE|(% style="width:443px" %) 116 +|(% style="width:196px" %)High voltage fault |(% style="width:58px" %)HVF|(% style="width:443px" %)failure of high voltage measuring circuits;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 117 +|(% style="width:196px" %)Power switch error |(% style="width:58px" %)PSE|(% style="width:443px" %)short circuit in contactor coil control circuit or power switch overheating;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 118 +|(% style="width:196px" %)HVIL error |(% style="width:58px" %)HE|(% style="width:443px" %)breakage of high-voltage interlock current loop;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 +|(% style="width:196px" %)Precharge error |(% style="width:58px" %)PE|(% style="width:443px" %)capacitive load pre-charge process did not end during the estimated time;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 120 +|(% style="width:196px" %)Power fault |(% style="width:58px" %)PF|(% style="width:443px" %)external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 121 +|(% style="width:196px" %)Current limit error |(% style="width:58px" %)CLE|(% style="width:443px" %)charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 122 122 123 123