Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,7 +11,7 @@ 11 11 (% style="width:1274px" %) 12 12 |=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 483px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 248px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus** 13 13 |=(% style="width: 98px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3** 14 -|(% style="width:198px" %)Battery cover |(% style="width:60px" %)CVR|(% style="width:483px" %)a signal from the battery cover;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 14 +|(% style="width:198px" %)Battery cover |(% style="width:60px" %)CVR|(% style="width:483px" %) a signal from the battery cover;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 15 15 |(% style="width:198px" %)Charger connected |(% style="width:60px" %)CON|(% style="width:483px" %) a signal indicating that charger is connected;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 16 16 |(% style="width:198px" %)Power up/down request |(% style="width:60px" %)PDN|(% style="width:483px" %) a request to power down the device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 17 17 |(% style="width:198px" %)Inhibit charging |(% style="width:60px" %)ICH|(% style="width:483px" %) a command to open the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) ... ... @@ -25,13 +25,11 @@ 25 25 |(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:60px" %)CDF|(% style="width:483px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 26 26 |(% style="width:198px" %)Main contactor feedback |(% style="width:60px" %)MCF|(% style="width:483px" %) a signal from main contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 27 27 |(% style="width:198px" %)Interlock |(% style="width:60px" %) |(% style="width:483px" %) a signal from interlock loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 -|(% style="width:198px" %)Fuse 1|(% style="width:60px" %)F1|(% style="width:483px" %) signal from fuse 1;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 -|(% style="width:198px" %)Fuse 2|(% style="width:60px" %)F2|(% style="width:483px" %)signal from fuse 2;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 -|(% style="width:198px" %)Fuse 3 |(% style="width:60px" %)F3|(% style="width:483px" %)signal from fuse 3;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 +|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:60px" %)F1, F2, F3|(% style="width:483px" %) signals from fuses;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 31 31 |(% style="width:198px" %)Circuit breaker status |(% style="width:60px" %)CBS|(% style="width:483px" %) status of protection disconnector;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 32 -|(% style="width:198px" %)Balancing request |(% style="width:60px" %) BR|(% style="width:483px" %) a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)33 -|(% style="width:198px" %)Close Main contactor |(% style="width:60px" %) CMC|(% style="width:483px" %) a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)34 -|(% style="width:198px" %)Close External 1 |(% style="width:60px" %) CE1|(% style="width:483px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)30 +|(% style="width:198px" %)Balancing request |(% style="width:60px" %) |(% style="width:483px" %) a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 31 +|(% style="width:198px" %)Close Main contactor |(% style="width:60px" %) |(% style="width:483px" %) a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 32 +|(% style="width:198px" %)Close External 1 |(% style="width:60px" %) |(% style="width:483px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 35 35 36 36 === List of internal states === 37 37 ... ... @@ -40,27 +40,27 @@ 40 40 (% style="width:1277px" %) 41 41 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 42 42 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 43 -|(% style="width:201px" %)Low SOC |(% style="width:55px" %) LOS|(% style="width:531px" %) a signal corresponding the low SOC of the battery;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)44 -|(% style="width:201px" %)High charging current |(% style="width:55px" %) HCC|(% style="width:531px" %) charging current is high;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)45 -|(% style="width:201px" %)Main contactor |(% style="width:55px" %) MCO|(% style="width:531px" %) state of the main contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)46 -|(% style="width:201px" %)Charging |(% style="width:55px" %) CH|(% style="width:531px" %) state of the charging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)47 -|(% style="width:201px" %)Allow charging |(% style="width:55px" %) ACH|(% style="width:531px" %) a signal for a charger to start charging;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)48 -|(% style="width:201px" %)Charging current present |(% style="width:55px" %) CCP|(% style="width:531px" %) the presence of the charging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)49 -|(% style="width:201px" %)Precharging |(% style="width:55px" %) PRE|(% style="width:531px" %) state of the precharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)50 -|(% style="width:201px" %)Discharging |(% style="width:55px" %) DCH|(% style="width:531px" %) state of the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)51 -|(% style="width:201px" %)Discharging current present |(% style="width:55px" %) DCP|(% style="width:531px" %) the presence of the discharging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)52 -|(% style="width:201px" %)Discharging (AUX) |(% style="width:55px" %) AUX|(% style="width:531px" %) state of the auxiliary discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)53 -|(% style="width:201px" %)Power down ACK |(% style="width:55px" %) PDA|(% style="width:531px" %) an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)54 -|(% style="width:201px" %)Charging/discharging|(% style="width:55px" %) C/D|(% style="width:531px" %)state of the charging/discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)55 -|(% style="width:201px" %)Heater |(% style="width:55px" %) HEA|(% style="width:531px" %) a command to turn on a heater;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)56 -|(% style="width:201px" %)Cooler |(% style="width:55px" %) COO|(% style="width:531px" %) a command to turn on a cooler;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)57 -|(% style="width:201px" %)Balancing 1 |(% style="width:55px" %) BA1|(% style="width:531px" %) balancing the first series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)58 -|(% style="width:201px" %)Balancing 2 |(% style="width:55px" %) BA2|(% style="width:531px" %) balancing the second series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)59 -|(% style="width:201px" %)Ready to charge |(% style="width:55px" %) RTC|(% style="width:531px" %) the battery is ready to be charged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)60 -|(% style="width:201px" %)Ready to discharge |(% style="width:55px" %) RTD|(% style="width:531px" %) the battery is ready to be discharged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)61 -|(% style="width:201px" %)Power up |(% style="width:55px" %) PUP|(% style="width:531px" %) an indication of BMS power status;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)41 +|(% style="width:201px" %)Low SOC |(% style="width:55px" %) |(% style="width:531px" %) a signal corresponding the low SOC of the battery;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 42 +|(% style="width:201px" %)High charging current |(% style="width:55px" %) |(% style="width:531px" %) charging current is high;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 43 +|(% style="width:201px" %)Main contactor |(% style="width:55px" %) |(% style="width:531px" %) state of the main contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 44 +|(% style="width:201px" %)Charging |(% style="width:55px" %) |(% style="width:531px" %) state of the charging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 45 +|(% style="width:201px" %)Allow charging |(% style="width:55px" %) |(% style="width:531px" %) a signal for a charger to start charging;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 46 +|(% style="width:201px" %)Charging current present |(% style="width:55px" %) |(% style="width:531px" %) the presence of the charging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 47 +|(% style="width:201px" %)Precharging |(% style="width:55px" %) |(% style="width:531px" %) state of the precharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 48 +|(% style="width:201px" %)Discharging |(% style="width:55px" %) |(% style="width:531px" %) state of the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 +|(% style="width:201px" %)Discharging current present |(% style="width:55px" %) |(% style="width:531px" %) the presence of the discharging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 +|(% style="width:201px" %)Discharging (AUX) |(% style="width:55px" %) |(% style="width:531px" %) state of the auxiliary discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 51 +|(% style="width:201px" %)Power down ACK |(% style="width:55px" %) |(% style="width:531px" %) an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 52 +|(% style="width:201px" %)Charging/discharging|(% style="width:55px" %) |(% style="width:531px" %)state of the charging/discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 +|(% style="width:201px" %)Heater |(% style="width:55px" %) |(% style="width:531px" %) a command to turn on a heater;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 54 +|(% style="width:201px" %)Cooler |(% style="width:55px" %) |(% style="width:531px" %) a command to turn on a cooler;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 55 +|(% style="width:201px" %)Balancing 1 |(% style="width:55px" %) |(% style="width:531px" %) balancing the first series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 56 +|(% style="width:201px" %)Balancing 2 |(% style="width:55px" %) |(% style="width:531px" %) balancing the second series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 +|(% style="width:201px" %)Ready to charge |(% style="width:55px" %) |(% style="width:531px" %) the battery is ready to be charged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 +|(% style="width:201px" %)Ready to discharge |(% style="width:55px" %) |(% style="width:531px" %) the battery is ready to be discharged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 59 +|(% style="width:201px" %)Power up |(% style="width:55px" %) |(% style="width:531px" %) an indication of BMS power status;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 62 |(% style="width:201px" %)General error |(% style="width:55px" %) |(% style="width:531px" %) state of the configurable (general) error;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 -|(% style="width:201px" %)External 1 |(% style="width:55px" %) EX1|(% style="width:531px" %) a signal that activates by the remote request.|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)61 +|(% style="width:201px" %)External 1 |(% style="width:55px" %) |(% style="width:531px" %) a signal that activates by the remote request.|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 64 64 65 65 === List of errors === 66 66