Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,22 +11,22 @@ 11 11 (% style="width:1274px" %) 12 12 |=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 53px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 248px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus** 13 13 |=(% style="width: 98px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3** 14 -|(% style="width:198px" %)Battery cover |(% style="width:53px" %) 15 -|(% style="width:198px" %)Charger connected |(% style="width:53px" %) 16 -|(% style="width:198px" %)Power up/down request |(% style="width:53px" %) 17 -|(% style="width:198px" %)Inhibit charging |(% style="width:53px" %) 18 -|(% style="width:198px" %)Inhibit discharging |(% style="width:53px" %) 19 -|(% style="width:198px" %)CH contactor feedback |(% style="width:53px" %) 20 -|(% style="width:198px" %)DCH contactor feedback |(% style="width:53px" %) 21 -|(% style="width:198px" %)Insulation status |(% style="width:53px" %) 22 -|(% style="width:198px" %)Charge request |(% style="width:53px" %) 23 -|(% style="width:198px" %)Discharge request |(% style="width:53px" %) 24 -|(% style="width:198px" %)PCH contactor feedback |(% style="width:53px" %) 25 -|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:53px" %) 26 -|(% style="width:198px" %)Main contactor feedback |(% style="width:53px" %) 14 +|(% style="width:198px" %)Battery cover |(% style="width:53px" %)CVR|(% style="width:500px" %) a signal from the battery cover;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 15 +|(% style="width:198px" %)Charger connected |(% style="width:53px" %)CON|(% style="width:500px" %) a signal indicating that charger is connected;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 16 +|(% style="width:198px" %)Power up/down request |(% style="width:53px" %)PDN|(% style="width:500px" %) a request to power down the device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 17 +|(% style="width:198px" %)Inhibit charging |(% style="width:53px" %)ICH|(% style="width:500px" %) a command to open the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 18 +|(% style="width:198px" %)Inhibit discharging |(% style="width:53px" %)IDC|(% style="width:500px" %) a command to open the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 19 +|(% style="width:198px" %)CH contactor feedback |(% style="width:53px" %)CCF|(% style="width:500px" %) a signal from charging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 20 +|(% style="width:198px" %)DCH contactor feedback |(% style="width:53px" %)DCF|(% style="width:500px" %) a signal from discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 21 +|(% style="width:198px" %)Insulation status |(% style="width:53px" %)INS|(% style="width:500px" %) a signal from an insulation monitoring device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 22 +|(% style="width:198px" %)Charge request |(% style="width:53px" %)CRE|(% style="width:500px" %) a request to close the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 23 +|(% style="width:198px" %)Discharge request |(% style="width:53px" %)DRE|(% style="width:500px" %) a request to close the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 24 +|(% style="width:198px" %)PCH contactor feedback |(% style="width:53px" %)PCF|(% style="width:500px" %) a signal from precharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 25 +|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:53px" %)CDF|(% style="width:500px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 26 +|(% style="width:198px" %)Main contactor feedback |(% style="width:53px" %)MCF|(% style="width:500px" %) a signal from main contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 27 27 |(% style="width:198px" %)Interlock |(% style="width:53px" %) |(% style="width:500px" %) a signal from interlock loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 -|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:53px" %) |(% style="width:500px" %) signals from fuses;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 -|(% style="width:198px" %)Circuit breaker status |(% style="width:53px" %) 28 +|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:53px" %)F1, F2, F3|(% style="width:500px" %) signals from fuses;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 +|(% style="width:198px" %)Circuit breaker status |(% style="width:53px" %)CBS|(% style="width:500px" %) status of protection disconnector;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 30 |(% style="width:198px" %)Balancing request |(% style="width:53px" %) |(% style="width:500px" %) a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 31 31 |(% style="width:198px" %)Close Main contactor |(% style="width:53px" %) |(% style="width:500px" %) a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 32 32 |(% style="width:198px" %)Close External 1 |(% style="width:53px" %) |(% style="width:500px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)