Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,19 +77,20 @@ 77 77 |(% style="width:196px" %)Water |(% style="width:58px" %)WA|(% style="width:443px" %) there is water in the battery enclosure;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 78 78 |(% style="width:196px" %)High Logic temperature |(% style="width:58px" %)LHT|(% style="width:443px" %) at least one of the Logic devices is overheated;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 79 79 |(% style="width:196px" %)Logic offline |(% style="width:58px" %)LOF|(% style="width:443px" %) at least one of the Logic devices is offline;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 80 -|(% style="width:196px" %)Critical error|(% style="width:58px" %)C RE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)80 +|(% style="width:196px" %)Critical error|(% style="width:58px" %)CER|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 81 81 |(% style="width:196px" %)Crown error |(% style="width:58px" %)CRO|(% style="width:443px" %) connection with a Crown forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 82 82 |(% style="width:196px" %)Cell count error |(% style="width:58px" %)CEL|(% style="width:443px" %) number of cells does not match the specified value;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 83 83 |(% style="width:196px" %)HYG offline |(% style="width:58px" %)HYG|(% style="width:443px" %) connection with a HYG forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 84 -|(% style="width:196px" %)Need acknowledge |(% style="width:58px" %) |(% style="width:443px" %) there is an unacknowledged error in Error journal;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 85 -|(% style="width:196px" %)Combilift offline |(% style="width:58px" %) |(% style="width:443px" %) connection with a Combilift forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 86 -|(% style="width:196px" %)Short circuit|(% style="width:58px" %) |(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 87 -|(% style="width:196px" %)High contactor temperature|(% style="width:58px" %) |(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 88 -|(% style="width:196px" %)ADC error |(% style="width:58px" %) |(% style="width:443px" %) current cannot be measured;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 89 -|(% style="width:196px" %)Current sensor error |(% style="width:58px" %) |(% style="width:443px" %) error in the current sensor circuit;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 90 -|(% style="width:196px" %)CH contactor cycles error |(% style="width:58px" %) |(% style="width:443px" %) switching frequency of the charging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 91 -|(% style="width:196px" %)DCH contactor cycles error |(% style="width:58px" %) |(% style="width:443px" %) switching frequency of the discharging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 -|(% style="width:196px" %)Shunt offline |(% style="width:58px" %) |(% style="width:443px" %) connection with the shunt current sensor is lost;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 84 +|(% style="width:196px" %)Need acknowledge |(% style="width:58px" %)ACK|(% style="width:443px" %) there is an unacknowledged error in Error journal;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 85 +|(% style="width:196px" %)Combilift offline |(% style="width:58px" %)COM|(% style="width:443px" %) connection with a Combilift forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 86 +|(% style="width:196px" %)Short circuit|(% style="width:58px" %)SHC|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 87 +|(% style="width:196px" %)High contactor temperature|(% style="width:58px" %)CHT|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 88 +|(% style="width:196px" %)Logic count error|(% style="width:58px" %)LOG|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 89 +|(% style="width:196px" %)ADC error |(% style="width:58px" %)ADC|(% style="width:443px" %) current cannot be measured;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 90 +|(% style="width:196px" %)Current sensor error |(% style="width:58px" %)CSE|(% style="width:443px" %) error in the current sensor circuit;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 91 +|(% style="width:196px" %)CH contactor cycles error |(% style="width:58px" %)CCC|(% style="width:443px" %) switching frequency of the charging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 +|(% style="width:196px" %)DCH contactor cycles error |(% style="width:58px" %)DCC|(% style="width:443px" %) switching frequency of the discharging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 +|(% style="width:196px" %)Shunt offline |(% style="width:58px" %)SHO|(% style="width:443px" %) connection with the shunt current sensor is lost;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 93 |(% style="width:196px" %)Shunt error |(% style="width:58px" %) |(% style="width:443px" %) internal error of the shunt current sensor;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 94 94 |(% style="width:196px" %)WDT reset |(% style="width:58px" %) |(% style="width:443px" %) watchdog timer reset the device;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 95 95 |(% style="width:196px" %)No temperature sensors |(% style="width:58px" %) |(% style="width:443px" %) the device has no temperature sensors connected;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)