Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,56 +9,56 @@ 9 9 Here is the list of available input signals of BMS Main 3. 10 10 11 11 (% style="width:1274px" %) 12 -|(% colspan="1" rowspan="2" style="width:198px" %)**Name**|(% colspan="1"rowspan="2" style="width:443px" %)**Description**|(% colspan="3" rowspan="1" style="width:254px" %)**Compability**|(% colspan="1" rowspan="2" style="width:143px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:140px" %)**Modbus**|(% colspan="1" rowspan="2" style="width:86px" %)**Abbreviation**13 -|(% style="width:94px" %)**Mini S / Mini**|(% style="width:77px" %)**Main 2.1**|(% style="width:81px" %)**Main 3** 14 -|(% style="width:198px" %)Battery cover |(% style="width:4 43px" %) a signal from the battery cover;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)15 -|(% style="width:198px" %)Charger connected |(% style="width:4 43px" %) a signal indicating that charger is connected;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)16 -|(% style="width:198px" %)Power up/down request |(% style="width:4 43px" %) a request to power down the device;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)17 -|(% style="width:198px" %)Inhibit charging |(% style="width:4 43px" %) a command to open the charging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)18 -|(% style="width:198px" %)Inhibit discharging |(% style="width:4 43px" %) a command to open the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)19 -|(% style="width:198px" %)CH contactor feedback |(% style="width:4 43px" %) a signal from charging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)20 -|(% style="width:198px" %)DCH contactor feedback |(% style="width:4 43px" %) a signal from discharging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)21 -|(% style="width:198px" %)Insulation status |(% style="width:4 43px" %) a signal from an insulation monitoring device;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)22 -|(% style="width:198px" %)Charge request |(% style="width:4 43px" %) a request to close the charging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)23 -|(% style="width:198px" %)Discharge request |(% style="width:4 43px" %) a request to close the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)24 -|(% style="width:198px" %)PCH contactor feedback |(% style="width:4 43px" %) a signal from precharging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)25 -|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:4 43px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)26 -|(% style="width:198px" %)Main contactor feedback |(% style="width:4 43px" %) a signal from main contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)27 -|(% style="width:198px" %)Interlock |(% style="width:4 43px" %) a signal from interlock loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)28 -|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:4 43px" %) signals from fuses;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)29 -|(% style="width:198px" %)Circuit breaker status |(% style="width:4 43px" %) status of protection disconnector;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)30 -|(% style="width:198px" %)Balancing request |(% style="width:4 43px" %) a request to balance the cells;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)31 -|(% style="width:198px" %)Close Main contactor |(% style="width:4 43px" %) a request to close the main contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)32 -|(% style="width:198px" %)Close External 1 |(% style="width:4 43px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)12 +|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 89px;" %)**Abbreviation**|=(% colspan="1" rowspan="2" style="width: 543px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 254px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus** 13 +|=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3** 14 +|(% style="width:198px" %)Battery cover |(% style="width:89px" %) |(% style="width:543px" %) a signal from the battery cover;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 15 +|(% style="width:198px" %)Charger connected |(% style="width:89px" %) |(% style="width:543px" %) a signal indicating that charger is connected;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 16 +|(% style="width:198px" %)Power up/down request |(% style="width:89px" %) |(% style="width:543px" %) a request to power down the device;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 17 +|(% style="width:198px" %)Inhibit charging |(% style="width:89px" %) |(% style="width:543px" %) a command to open the charging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 18 +|(% style="width:198px" %)Inhibit discharging |(% style="width:89px" %) |(% style="width:543px" %) a command to open the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 19 +|(% style="width:198px" %)CH contactor feedback |(% style="width:89px" %) |(% style="width:543px" %) a signal from charging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 20 +|(% style="width:198px" %)DCH contactor feedback |(% style="width:89px" %) |(% style="width:543px" %) a signal from discharging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 21 +|(% style="width:198px" %)Insulation status |(% style="width:89px" %) |(% style="width:543px" %) a signal from an insulation monitoring device;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 22 +|(% style="width:198px" %)Charge request |(% style="width:89px" %) |(% style="width:543px" %) a request to close the charging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 23 +|(% style="width:198px" %)Discharge request |(% style="width:89px" %) |(% style="width:543px" %) a request to close the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 24 +|(% style="width:198px" %)PCH contactor feedback |(% style="width:89px" %) |(% style="width:543px" %) a signal from precharging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 25 +|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:89px" %) |(% style="width:543px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 26 +|(% style="width:198px" %)Main contactor feedback |(% style="width:89px" %) |(% style="width:543px" %) a signal from main contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 27 +|(% style="width:198px" %)Interlock |(% style="width:89px" %) |(% style="width:543px" %) a signal from interlock loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 +|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:89px" %) |(% style="width:543px" %) signals from fuses;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 +|(% style="width:198px" %)Circuit breaker status |(% style="width:89px" %) |(% style="width:543px" %) status of protection disconnector;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 +|(% style="width:198px" %)Balancing request |(% style="width:89px" %) |(% style="width:543px" %) a request to balance the cells;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 31 +|(% style="width:198px" %)Close Main contactor |(% style="width:89px" %) |(% style="width:543px" %) a request to close the main contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 32 +|(% style="width:198px" %)Close External 1 |(% style="width:89px" %) |(% style="width:543px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 33 33 34 34 === List of internal states === 35 35 36 36 Here is the list of available internal states of BMS Main 3. 37 37 38 -(% style="width:1 158px" %)39 -|(% colspan="1" style="width:21 6px" %)**Name**|(% colspan="1" style="width:322px" %)**Description**|(% colspan="1" style="width:97px" %)**Compability**|(% style="width:65px" %) |(% style="width:56px" %)4" rowspan="1" style="width:408px" %)**Outputby**40 -|(% colspan="1" style="width:216px" %) |(% colspan="1" style="width:322px" %)**Description**|(% style="width:97px" %)**Mini S / Mini**|(% style="width:65px" %)**Main 2.1**|(% style="width:56px" %)**Main 3**|(% style="width:227px" %)**Discrete output**|(% style="width:60px" %)**Switch**|(% style="width:52px" %)**CAN**|(% style="width:70px" %)**Modbus**41 -|Low SOC |(% style="width:3 22px" %) a signal corresponding the low SOC of the battery;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)42 -|High charging current |(% style="width:3 22px" %) charging current is high;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)43 -|Main contactor |(% style="width:3 22px" %) state of the main contactor;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)44 -|Charging |(% style="width:3 22px" %) state of the charging contactor;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)45 -|Allow charging |(% style="width:3 22px" %) a signal for a charger to start charging;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)46 -|Charging current present |(% style="width:3 22px" %) the presence of the charging current;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)47 -|Precharging |(% style="width:3 22px" %) state of the precharging contactor;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)48 -|Discharging |(% style="width:3 22px" %) state of the discharging contactor;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)49 -|Discharging current present |(% style="width:3 22px" %) the presence of the discharging current;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)50 -|Discharging (AUX) |(% style="width:3 22px" %) state of the auxiliary discharging contactor;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)51 -|Power down ACK |(% style="width:3 22px" %) an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)52 -|Charging/discharging|(% style="width:3 22px" %)state of the charging/discharging contactor;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)53 -|Heater |(% style="width:3 22px" %) a command to turn on a heater;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)54 -|Cooler |(% style="width:3 22px" %) a command to turn on a cooler;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)55 -|Balancing 1 |(% style="width:3 22px" %) balancing the first series of cells;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)56 -|Balancing 2 |(% style="width:3 22px" %) balancing the second series of cells;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)57 -|Ready to charge |(% style="width:3 22px" %) the battery is ready to be charged;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)58 -|Ready to discharge |(% style="width:3 22px" %) the battery is ready to be discharged;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)59 -|Power up |(% style="width:3 22px" %) an indication of BMS power status;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)60 -|General error |(% style="width:3 22px" %) state of the configurable (general) error;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)60px" %) |(% style="width:52px" %) |(% style="width:70px" %)61 -|External 1 |(% style="width:3 22px" %) a signal that activates by the remote request.|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)60px" %) |(% style="width:52px" %) |(% style="width:70px" %)38 +(% style="width:1277px" %) 39 +|(% colspan="1" rowspan="2" style="width:201px" %)**Name**|(% colspan="1" rowspan="2" style="width:439px" %)**Description**|(% colspan="3" rowspan="1" style="width:255px" %)**Compability**|(% colspan="1" rowspan="2" style="width:140px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:142px" %)**Modbus**|(% colspan="1" rowspan="2" style="width:94px" %)**Abbreviation** 40 +|(% style="width:94px" %)**Mini S / Mini**|(% style="width:75px" %)**Main 2.1**|(% style="width:84px" %)**Main 3** 41 +|(% style="width:201px" %)Low SOC |(% style="width:439px" %) a signal corresponding the low SOC of the battery;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 42 +|(% style="width:201px" %)High charging current |(% style="width:439px" %) charging current is high;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 43 +|(% style="width:201px" %)Main contactor |(% style="width:439px" %) state of the main contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 44 +|(% style="width:201px" %)Charging |(% style="width:439px" %) state of the charging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 45 +|(% style="width:201px" %)Allow charging |(% style="width:439px" %) a signal for a charger to start charging;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 46 +|(% style="width:201px" %)Charging current present |(% style="width:439px" %) the presence of the charging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 47 +|(% style="width:201px" %)Precharging |(% style="width:439px" %) state of the precharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 48 +|(% style="width:201px" %)Discharging |(% style="width:439px" %) state of the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 49 +|(% style="width:201px" %)Discharging current present |(% style="width:439px" %) the presence of the discharging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 50 +|(% style="width:201px" %)Discharging (AUX) |(% style="width:439px" %) state of the auxiliary discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 51 +|(% style="width:201px" %)Power down ACK |(% style="width:439px" %) an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 52 +|(% style="width:201px" %)Charging/discharging|(% style="width:439px" %)state of the charging/discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 53 +|(% style="width:201px" %)Heater |(% style="width:439px" %) a command to turn on a heater;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 54 +|(% style="width:201px" %)Cooler |(% style="width:439px" %) a command to turn on a cooler;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 55 +|(% style="width:201px" %)Balancing 1 |(% style="width:439px" %) balancing the first series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 56 +|(% style="width:201px" %)Balancing 2 |(% style="width:439px" %) balancing the second series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 57 +|(% style="width:201px" %)Ready to charge |(% style="width:439px" %) the battery is ready to be charged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 58 +|(% style="width:201px" %)Ready to discharge |(% style="width:439px" %) the battery is ready to be discharged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 59 +|(% style="width:201px" %)Power up |(% style="width:439px" %) an indication of BMS power status;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 60 +|(% style="width:201px" %)General error |(% style="width:439px" %) state of the configurable (general) error;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 61 +|(% style="width:201px" %)External 1 |(% style="width:439px" %) a signal that activates by the remote request.|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) |(% style="width:94px" %) 62 62 63 63 === List of errors === 64 64