Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,27 +9,27 @@ 9 9 Here is the list of available input signals of BMS Main 3. 10 10 11 11 (% style="width:1274px" %) 12 -|(% style="width:1 31px" %)**Name**|(% style="width:451px" %)**Description**|(% colspan="3" rowspan="1" style="width:414px" %)**Compability**|(% style="width:83px" %)**CANopen SDO**|(% style="width:113px" %)**Modbus**|(% style="width:86px" %)**Abbreviation**13 -|(% style="width: 131px" %)|(% style="width:451px" %) |(% style="width:91px" %)**Mini S / Mini**|(% style="width:178px" %)**Main 2.1**|(% style="width:142px" %)**Main 3**|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)14 -|(% style="width:1 31px" %)Battery cover |(% style="width:451px" %) a signal from the battery cover;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)15 -|(% style="width:1 31px" %)Charger connected |(% style="width:451px" %) a signal indicating that charger is connected;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)16 -|(% style="width:1 31px" %)Power up/down request |(% style="width:451px" %) a request to power down the device;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)17 -|(% style="width:1 31px" %)Inhibit charging |(% style="width:451px" %) a command to open the charging contactor;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)18 -|(% style="width:1 31px" %)Inhibit discharging |(% style="width:451px" %) a command to open the discharging contactor;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)19 -|(% style="width:1 31px" %)CH contactor feedback |(% style="width:451px" %) a signal from charging contactor feedback loop;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)20 -|(% style="width:1 31px" %)DCH contactor feedback |(% style="width:451px" %) a signal from discharging contactor feedback loop;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)21 -|(% style="width:1 31px" %)Insulation status |(% style="width:451px" %) a signal from an insulation monitoring device;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)22 -|(% style="width:1 31px" %)Charge request |(% style="width:451px" %) a request to close the charging contactor;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)23 -|(% style="width:1 31px" %)Discharge request |(% style="width:451px" %) a request to close the discharging contactor;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)24 -|(% style="width:1 31px" %)PCH contactor feedback |(% style="width:451px" %) a signal from precharging contactor feedback loop;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)25 -|(% style="width:1 31px" %)CH/DCH contactor feedback |(% style="width:451px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)26 -|(% style="width:1 31px" %)Main contactor feedback |(% style="width:451px" %) a signal from main contactor feedback loop;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)27 -|(% style="width:1 31px" %)Interlock |(% style="width:451px" %) a signal from interlock loop;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)28 -|(% style="width:1 31px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:451px" %) signals from fuses;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)29 -|(% style="width:1 31px" %)Circuit breaker status |(% style="width:451px" %) status of protection disconnector;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)30 -|(% style="width:1 31px" %)Balancing request |(% style="width:451px" %) a request to balance the cells;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %)•|(% style="width:113px" %) |(% style="width:86px" %)31 -|(% style="width:1 31px" %)Close Main contactor |(% style="width:451px" %) a request to close the main contactor;|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %)• (by request)|(% style="width:113px" %) |(% style="width:86px" %)32 -|(% style="width:1 31px" %)Close External 1 |(% style="width:451px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:91px" %)Yes|(% style="width:178px" %)Yes|(% style="width:134px" %)Yes|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)12 +|(% colspan="1" rowspan="2" style="width:198px" %)**Name**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="3" rowspan="1" style="width:254px" %)**Compability**|(% colspan="1" rowspan="2" style="width:89px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:198px" %)**Modbus**|(% colspan="1" rowspan="2" style="width:86px" %)**Abbreviation** 13 +|(% style="width:30px" %)**Mini S / Mini**|(% style="width:119px" %)**Main 2.1**|(% style="width:96px" %)**Main 3** 14 +|(% style="width:198px" %)Battery cover |(% style="width:443px" %) a signal from the battery cover;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 15 +|(% style="width:198px" %)Charger connected |(% style="width:443px" %) a signal indicating that charger is connected;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 16 +|(% style="width:198px" %)Power up/down request |(% style="width:443px" %) a request to power down the device;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 17 +|(% style="width:198px" %)Inhibit charging |(% style="width:443px" %) a command to open the charging contactor;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 18 +|(% style="width:198px" %)Inhibit discharging |(% style="width:443px" %) a command to open the discharging contactor;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 19 +|(% style="width:198px" %)CH contactor feedback |(% style="width:443px" %) a signal from charging contactor feedback loop;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 20 +|(% style="width:198px" %)DCH contactor feedback |(% style="width:443px" %) a signal from discharging contactor feedback loop;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 21 +|(% style="width:198px" %)Insulation status |(% style="width:443px" %) a signal from an insulation monitoring device;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 22 +|(% style="width:198px" %)Charge request |(% style="width:443px" %) a request to close the charging contactor;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 23 +|(% style="width:198px" %)Discharge request |(% style="width:443px" %) a request to close the discharging contactor;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 24 +|(% style="width:198px" %)PCH contactor feedback |(% style="width:443px" %) a signal from precharging contactor feedback loop;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 25 +|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:443px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 26 +|(% style="width:198px" %)Main contactor feedback |(% style="width:443px" %) a signal from main contactor feedback loop;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 27 +|(% style="width:198px" %)Interlock |(% style="width:443px" %) a signal from interlock loop;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 28 +|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:443px" %) signals from fuses;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 29 +|(% style="width:198px" %)Circuit breaker status |(% style="width:443px" %) status of protection disconnector;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 30 +|(% style="width:198px" %)Balancing request |(% style="width:443px" %) a request to balance the cells;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %)•|(% style="width:198px" %) |(% style="width:86px" %) 31 +|(% style="width:198px" %)Close Main contactor |(% style="width:443px" %) a request to close the main contactor;|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %)• (by request)|(% style="width:198px" %) |(% style="width:86px" %) 32 +|(% style="width:198px" %)Close External 1 |(% style="width:443px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:30px" %)Yes|(% style="width:119px" %)Yes|(% style="width:96px" %)Yes|(% style="width:89px" %) |(% style="width:198px" %) |(% style="width:86px" %) 33 33 34 34 === List of internal states === 35 35