... ... @@ -1,1 +1,1 @@ 1 - 3.1Generalinformation1 +2. Strings controllers: signals and errors - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.WebHome1 +Battery management systems.Additional information.WebHome - Content
-
... ... @@ -1,115 +1,102 @@ 1 -(% data-numbered-headings-start=" 3" style="--numbered-headings-start:2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)2 -= Configuration =1 +(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Strings controllers: signals, states and errors = 3 3 4 -(% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -== General information == 4 +== Input signals == 6 6 7 - ===List of input signals===6 +Below is the list of input signals that can be assigned to discrete inputs of the battery strings controller. 8 8 9 -Here is the list of available input signals of BMS Main 3. 8 +* **Remote control values**: Off = 0, On = 1, Use physical input = 2-65535. 9 +* **Status values**: Off = 0, On = 1. 10 10 11 -(% style="width:1093px" %) 12 -|(% colspan="1" rowspan="2" style="width:131px" %)**Name**|(% rowspan="2" style="width:43px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:414px" %)**Description**|(% colspan="1" rowspan="2" style="width:330px" %)**Used by**|(% colspan="3" rowspan="1" style="width:190px" %)**Set up by** 13 -|(% style="width:27px" %)**Dis. input**|(% style="width:69px" %)**CAN**|(% style="width:65px" %)**Modbus** 14 -|(% style="width:131px" %)Battery cover |(% style="width:43px" %) |(% style="width:414px" %) a signal from the battery cover;|(% style="width:330px" %)Battery cover protection ([[Main 3>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]], [[Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycover"]], [[Mini S / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]])|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 15 -|(% style="width:131px" %)Charger connected |(% style="width:43px" %) |(% style="width:414px" %) a signal indicating that charger is connected;|(% style="width:330px" %)Charge controller, Discharge controller|(% style="width:27px" %)•|(% style="width:69px" %)• (if corresponding External equipment is online)|(% style="width:65px" %) 16 -|(% style="width:131px" %)Power up/down request |(% style="width:43px" %) |(% style="width:414px" %) a request to power down the device;|(% style="width:330px" %)Power down controller|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 17 -|(% style="width:131px" %)Inhibit charging |(% style="width:43px" %) |(% style="width:414px" %) a command to open the charging contactor;|(% style="width:330px" %) |(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 18 -|(% style="width:131px" %)Inhibit discharging |(% style="width:43px" %) |(% style="width:414px" %) a command to open the discharging contactor;|(% style="width:330px" %) |(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 19 -|(% style="width:131px" %)CH contactor feedback |(% style="width:43px" %) |(% style="width:414px" %) a signal from charging contactor feedback loop;|(% style="width:330px" %)Contactor feedback protection|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 20 -|(% style="width:131px" %)DCH contactor feedback |(% style="width:43px" %) |(% style="width:414px" %) a signal from discharging contactor feedback loop;|(% style="width:330px" %)Contactor feedback protection|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 21 -|(% style="width:131px" %)Insulation status |(% style="width:43px" %) |(% style="width:414px" %) a signal from an insulation monitoring device;|(% style="width:330px" %)Insulation protection|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 22 -|(% style="width:131px" %)Charge request |(% style="width:43px" %) |(% style="width:414px" %) a request to close the charging contactor;|(% style="width:330px" %)Charge controller|(% style="width:27px" %)•|(% style="width:69px" %)• (by request)|(% style="width:65px" %) 23 -|(% style="width:131px" %)Discharge request |(% style="width:43px" %) |(% style="width:414px" %) a request to close the discharging contactor;|(% style="width:330px" %)Discharge controller|(% style="width:27px" %)•|(% style="width:69px" %)• (by request)|(% style="width:65px" %) 24 -|(% style="width:131px" %)PCH contactor feedback |(% style="width:43px" %) |(% style="width:414px" %) a signal from precharging contactor feedback loop;|(% style="width:330px" %)Contactor feedback protection|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 25 -|(% style="width:131px" %)CH/DCH contactor feedback |(% style="width:43px" %) |(% style="width:414px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:330px" %)Contactor feedback protection|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 26 -|(% style="width:131px" %)Main contactor feedback |(% style="width:43px" %) |(% style="width:414px" %) a signal from main contactor feedback loop;|(% style="width:330px" %)Contactor feedback protection|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 27 -|(% style="width:131px" %)Interlock |(% style="width:43px" %) |(% style="width:414px" %) a signal from interlock loop;|(% style="width:330px" %)Interlock protection|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 28 -|(% style="width:131px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:43px" %) |(% style="width:414px" %) signals from fuses;|(% style="width:330px" %) |(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 29 -|(% style="width:131px" %)Circuit breaker status |(% style="width:43px" %) |(% style="width:414px" %) status of protection disconnector;|(% style="width:330px" %) |(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 30 -|(% style="width:131px" %)Balancing request |(% style="width:43px" %) |(% style="width:414px" %) a request to balance the cells;|(% style="width:330px" %)Cell balance controller|(% style="width:27px" %)•|(% style="width:69px" %)•|(% style="width:65px" %) 31 -|(% style="width:131px" %)Close Main contactor |(% style="width:43px" %) |(% style="width:414px" %) a request to close the main contactor;|(% style="width:330px" %)Main contactor controller|(% style="width:27px" %)•|(% style="width:69px" %)• (by request)|(% style="width:65px" %) 32 -|(% style="width:131px" %)Close External 1 |(% style="width:43px" %) |(% style="width:414px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:330px" %)External 1 internal state|(% style="width:27px" %)•|(% style="width:69px" %) |(% style="width:65px" %) 11 +(% style="width:1474px" %) 12 +|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 360px;" %)**Description**|=(% colspan="2" rowspan="1" style="width: 140px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 184px;" %)BMS DIsplay|=(% colspan="2" rowspan="1" style="width: 299px;" %)**Remote control**|=(% colspan="2" rowspan="1" style="width: 332px;" %)Status 13 +|=(% style="width: 62px;" %)**Main X**|=(% style="width: 76px;" %)**Main 3X**|=(% colspan="1" style="width: 121px;" %)Short name|=(% style="width: 63px;" %)Abbr.|=(% colspan="1" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" style="width: 158px;" %)**Modbus, holding regs**|=(% colspan="1" style="width: 165px;" %)**CANopen SDO**|=(% colspan="1" style="width: 166px;" %)**Modbus, input regs** 14 +|Battery cover|(% style="width:360px" %)Signal from the battery cover|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Battery cover|(% style="width:63px" %)CVR|(% style="width:137px" %)0x5000 sub 0x01|(% style="width:158px" %)0x5000|(% style="width:165px" %)0x4000 sub 0x00, bit 0|(% style="width:166px" %)0x103A-0x103B, bit 0 15 +|CH contactor feedback|(% style="width:360px" %)Signal from the charging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)CH cont. feed.|(% style="width:63px" %)CCF|(% style="width:137px" %)0x5000 sub 0x05|(% style="width:158px" %)0x5004|(% style="width:165px" %)0x4000 sub 0x00, bit 4|(% style="width:166px" %)0x103A-0x103B, bit 4 16 +|CH/DCH contactor feedback|(% style="width:360px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)C/D cont. feed.|(% style="width:63px" %)CDF|(% style="width:137px" %)0x5000 sub 0x07|(% style="width:158px" %)0x5006|(% style="width:165px" %)0x4000 sub 0x00, bit 6|(% style="width:166px" %)0x103A-0x103B, bit 6 17 +|Charge request|(% style="width:360px" %)Request to close the charging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Charge request|(% style="width:63px" %)CRE|(% style="width:137px" %)0x5000 sub 0x02|(% style="width:158px" %)0x5001|(% style="width:165px" %)0x4000 sub 0x00, bit 1|(% style="width:166px" %)0x103A-0x103B, bit 1 18 +|DCH contactor feedback|(% style="width:360px" %)Signal from the discharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)DCH cont. feed.|(% style="width:63px" %)DCF|(% style="width:137px" %)0x5000 sub 0x06|(% style="width:158px" %)0x5005|(% style="width:165px" %)0x4000 sub 0x00, bit 5|(% style="width:166px" %)0x103A-0x103B, bit 5 19 +|Discharge request|(% style="width:360px" %)Request to close the discharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Discharge req.|(% style="width:63px" %)DRE|(% style="width:137px" %)0x5000 sub 0x04|(% style="width:158px" %)0x5003|(% style="width:165px" %)0x4000 sub 0x00, bit 3|(% style="width:166px" %)0x103A-0x103B, bit 3 20 +|Insulation status|(% style="width:360px" %)Signal from an insulation monitoring device|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Insul. status|(% style="width:63px" %)INS|(% style="width:137px" %)0x5000 sub 0x08|(% style="width:158px" %)0x5007|(% style="width:165px" %)0x4000 sub 0x00, bit 7|(% style="width:166px" %)0x103A-0x103B, bit 7 21 +|Interlock|(% style="width:360px" %)Signal from the interlock loop|(% style="width:62px" %) |(% style="width:76px" %)Yes|(% style="width:121px" %)Interlock|(% style="width:63px" %)INT|(% style="width:137px" %)0x5000 sub 0x0D|(% style="width:158px" %)0x500C|(% style="width:165px" %)0x4000 sub 0x00, bit 12|(% style="width:166px" %)0x103A-0x103B, bit 12 22 +|Join to charge|(% style="width:360px" %)Request to join the battery modules for charging|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Join to charge|(% style="width:63px" %)JTC|(% style="width:137px" %)0x5000 sub 0x09|(% style="width:158px" %)0x5008|(% style="width:165px" %)0x4000 sub 0x00, bit 8|(% style="width:166px" %)0x103A-0x103B, bit 8 23 +|Join to discharge|(% style="width:360px" %)Request to join the battery modules for discharging|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Join to dischar.|(% style="width:63px" %)JTD|(% style="width:137px" %)0x5000 sub 0x0A|(% style="width:158px" %)0x5009|(% style="width:165px" %)0x4000 sub 0x00, bit 9|(% style="width:166px" %)0x103A-0x103B, bit 9 24 +|Main contactor feedback|(% style="width:360px" %)Signal from the main contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Main cont. feed.|(% style="width:63px" %)MCF|(% style="width:137px" %)0x5000 sub 0x0C|(% style="width:158px" %)0x500B|(% style="width:165px" %)0x4000 sub 0x00, bit 11|(% style="width:166px" %)0x103A-0x103B, bit 11 25 +|PCH contactor feedback|(% style="width:360px" %)Signal from the precharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)PCH cont. feed.|(% style="width:63px" %)PCF|(% style="width:137px" %)0x5000 sub 0x0B|(% style="width:158px" %)0x500A|(% style="width:165px" %)0x4000 sub 0x00, bit 10|(% style="width:166px" %)0x103A-0x103B, bit 10 26 +|Power down request|(% style="width:360px" %)Request to power down the device|(% style="width:62px" %) |(% style="width:76px" %)Yes|(% style="width:121px" %)Power down req.|(% style="width:63px" %)PDN|(% style="width:137px" %)0x5000 sub 0x0E|(% style="width:158px" %)0x500D|(% style="width:165px" %)0x4000 sub 0x00, bit 13|(% style="width:166px" %)0x103A-0x103B, bit 13 27 +|Precharge request|(% style="width:360px" %)Request to close the precharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Precharge req.|(% style="width:63px" %)PRE|(% style="width:137px" %)0x5000 sub 0x03|(% style="width:158px" %)0x5002|(% style="width:165px" %)0x4000 sub 0x00, bit 2|(% style="width:166px" %)0x103A-0x103B, bit 2 33 33 34 -== =List of internal states ===29 +== Internal signals == 35 35 36 - Hereis the list ofavailableinternal states ofBMSMain3.31 +Below is the list of internal strings controller signals. Most signals can be assigned to discrete outputs and relays. 37 37 38 -(% style="width:1158px" %) 39 -|(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% rowspan="2" style="width:75px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:322px" %)**Description**|(% colspan="1" rowspan="2" style="width:173px" %)**Set up by**|(% rowspan="2" style="width:105px" %)**Used by**|(% colspan="4" rowspan="1" style="width:257px" %)**Output by** 40 -|(% style="width:79px" %)**Discrete output**|(% style="width:60px" %)**Switch**|(% style="width:52px" %)**CAN**|(% style="width:70px" %)**Modbus** 41 -|Low SOC |(% style="width:75px" %) |(% style="width:322px" %) a signal corresponding the low SOC of the battery;|(% style="width:173px" %)Low SOC signal controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 42 -|High charging current |(% style="width:75px" %) |(% style="width:322px" %) charging current is high;|(% style="width:173px" %)High charging signal controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 43 -|Main contactor |(% style="width:75px" %) |(% style="width:322px" %) state of the main contactor;|(% style="width:173px" %)Main contactor controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 44 -|Charging |(% style="width:75px" %) |(% style="width:322px" %) state of the charging contactor;|(% style="width:173px" %)Charge controller, Charge/Discharge controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 45 -|Allow charging |(% style="width:75px" %) |(% style="width:322px" %) a signal for a charger to start charging;|(% style="width:173px" %)Charge controller, Charge/Discharge controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 46 -|Charging current present |(% style="width:75px" %) |(% style="width:322px" %) the presence of the charging current;|(% style="width:173px" %)Charging status controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 47 -|Precharging |(% style="width:75px" %) |(% style="width:322px" %) state of the precharging contactor;|(% style="width:173px" %)Precharge controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 48 -|Discharging |(% style="width:75px" %) |(% style="width:322px" %) state of the discharging contactor;|(% style="width:173px" %)Discharge controller, Charge/Discharge controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 49 -|Discharging current present |(% style="width:75px" %) |(% style="width:322px" %) the presence of the discharging current;|(% style="width:173px" %)Discharging status controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 50 -|Discharging (AUX) |(% style="width:75px" %) |(% style="width:322px" %) state of the auxiliary discharging contactor;|(% style="width:173px" %)Discharging (AUX) controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 51 -|Power down ACK |(% style="width:75px" %) |(% style="width:322px" %) an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:173px" %)Power down controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 52 -|Charging/discharging|(% style="width:75px" %) |(% style="width:322px" %)state of the charging/discharging contactor;|(% style="width:173px" %)Charge/Discharge controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 53 -|Heater |(% style="width:75px" %) |(% style="width:322px" %) a command to turn on a heater;|(% style="width:173px" %)Heater controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 54 -|Cooler |(% style="width:75px" %) |(% style="width:322px" %) a command to turn on a cooler;|(% style="width:173px" %)Cooler controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 55 -|Balancing 1 |(% style="width:75px" %) |(% style="width:322px" %) balancing the first series of cells;|(% style="width:173px" %)Series balancing controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 56 -|Balancing 2 |(% style="width:75px" %) |(% style="width:322px" %) balancing the second series of cells;|(% style="width:173px" %)Series balancing controller|(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 57 -|Ready to charge |(% style="width:75px" %) |(% style="width:322px" %) the battery is ready to be charged;|(% style="width:173px" %)Charging status controller|(% style="width:105px" %)Charge controller (optionally)|(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 58 -|Ready to discharge |(% style="width:75px" %) |(% style="width:322px" %) the battery is ready to be discharged;|(% style="width:173px" %)Discharging status controller|(% style="width:105px" %)Discharge controller (optionally)|(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 59 -|Power up |(% style="width:75px" %) |(% style="width:322px" %) an indication of BMS power status;|(% style="width:173px" %) |(% style="width:105px" %) |(% style="width:79px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %) 60 -|General error |(% style="width:75px" %) |(% style="width:322px" %) state of the configurable (general) error;|(% style="width:173px" %)General error protection|(% style="width:105px" %) |(% style="width:79px" %) |(% style="width:60px" %) |(% style="width:52px" %) |(% style="width:70px" %) 61 -|External 1 |(% style="width:75px" %) |(% style="width:322px" %) a signal that activates by the remote request.|(% style="width:173px" %)External 1 input signal|(% style="width:105px" %) |(% style="width:79px" %) |(% style="width:60px" %) |(% style="width:52px" %) |(% style="width:70px" %) 33 +* **Status values**: Off = 0, On = 1. 62 62 63 -=== List of errors === 35 +(% style="width:1374px" %) 36 +|=(% colspan="1" rowspan="2" style="width: 188px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 474px;" %)**Description**|=(% colspan="2" rowspan="1" style="width: 133px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 190px;" %)BMS Display|=(% colspan="2" rowspan="1" style="width: 385px;" %)Status 37 +|=(% style="width: 62px;" %)**Main X**|=(% style="width: 71px;" %)**Main 3X**|=(% colspan="1" style="width: 140px;" %)Short name|=(% style="width: 50px;" %)Abbr.|=(% colspan="1" style="width: 191px;" %)**CANopen SDO**|=(% colspan="1" style="width: 194px;" %)**Modbus, input regs** 38 +|(% style="width:188px" %)Charging current present|(% style="width:474px" %)Signal showing the presence of the charging current|(% style="width:62px" %)Yes*|(% style="width:71px" %)Yes*|(% style="width:140px" %)CH curr. present|(% style="width:50px" %)CCP|(% style="width:191px" %)0x4030 sub 0x00, bit 3|(% style="width:194px" %)0x1020-0x1021, bit 3 39 +|(% style="width:188px" %)Charging|(% style="width:474px" %)Command to control the charging contactor|(% style="width:62px" %)Yes|(% style="width:71px" %)Yes|(% style="width:140px" %)Charging|(% style="width:50px" %)CH|(% style="width:191px" %)0x4030 sub 0x00, bit 1|(% style="width:194px" %)0x1020-0x1021, bit 1 40 +|(% style="width:188px" %)Charging/Discharging|(% style="width:474px" %)Command to control the charging/discharging contactor|(% style="width:62px" %)Yes|(% style="width:71px" %)Yes|(% style="width:140px" %)Charg./Discharg.|(% style="width:50px" %)C/D|(% style="width:191px" %)0x4030 sub 0x00, bit 5|(% style="width:194px" %)0x1020-0x1021, bit 5 41 +|(% style="width:188px" %)Coolant pump|(% style="width:474px" %)Command to control the coolant pump|(% style="width:62px" %)Yes|(% style="width:71px" %)Yes|(% style="width:140px" %)Coolant pump|(% style="width:50px" %)CP|(% style="width:191px" %)0x4030 sub 0x00, bit 15|(% style="width:194px" %)0x1020-0x1021, bit 15 42 +|(% style="width:188px" %)Cooler|(% style="width:474px" %)Command to control the cooler|(% style="width:62px" %)Yes|(% style="width:71px" %)Yes|(% style="width:140px" %)Cooler|(% style="width:50px" %)COO|(% style="width:191px" %)0x4030 sub 0x00, bit 12|(% style="width:194px" %)0x1020-0x1021, bit 12 43 +|(% style="width:188px" %)Discharging current present|(% style="width:474px" %)Signal showing the presence of the discharging current|(% style="width:62px" %)Yes*|(% style="width:71px" %)Yes*|(% style="width:140px" %)DCH cur. present|(% style="width:50px" %)DCP|(% style="width:191px" %)0x4030 sub 0x00, bit 4|(% style="width:194px" %)0x1020-0x1021, bit 4 44 +|(% style="width:188px" %)Discharging|(% style="width:474px" %)Command to control the discharging contactor|(% style="width:62px" %)Yes|(% style="width:71px" %)Yes|(% style="width:140px" %)Discharging|(% style="width:50px" %)DCH|(% style="width:191px" %)0x4030 sub 0x00, bit 2|(% style="width:194px" %)0x1020-0x1021, bit 2 45 +|(% style="width:188px" %)Fuse 1 (modules)|(% style="width:474px" %)ORed internal signals "Fuse 1" from all battery modules|(% style="width:62px" %)Yes*|(% style="width:71px" %)Yes*|(% style="width:140px" %)Fuse 1 (mod.)|(% style="width:50px" %)F1M|(% style="width:191px" %)0x4030 sub 0x00, bit 8|(% style="width:194px" %)0x1020-0x1021, bit 8 46 +|(% style="width:188px" %)Fuse 2 (modules)|(% style="width:474px" %)ORed internal signals "Fuse 2" from all battery modules|(% style="width:62px" %)Yes*|(% style="width:71px" %)Yes*|(% style="width:140px" %)Fuse 2 (mod.)|(% style="width:50px" %)F2M|(% style="width:191px" %)0x4030 sub 0x00, bit 9|(% style="width:194px" %)0x1020-0x1021, bit 9 47 +|(% style="width:188px" %)Fuse 3 (modules)|(% style="width:474px" %)ORed internal signals "Fuse 3" from all battery modules|(% style="width:62px" %)Yes*|(% style="width:71px" %)Yes*|(% style="width:140px" %)Fuse 3 (mod.)|(% style="width:50px" %)F3M|(% style="width:191px" %)0x4030 sub 0x00,bit 10|(% style="width:194px" %)0x1020-0x1021, bit 10 48 +|(% style="width:188px" %)General error (modules)|(% style="width:474px" %)ORed internal signals "General error" from all battery modules|(% style="width:62px" %)Yes|(% style="width:71px" %)Yes|(% style="width:140px" %)Gen.error (mod.)|(% style="width:50px" %)GEM|(% style="width:191px" %)0x4030 sub 0x00, bit 16|(% style="width:194px" %)0x1020-0x1021, bit 16 49 +|(% style="width:188px" %)Heater|(% style="width:474px" %)Command to control the heater|(% style="width:62px" %)Yes|(% style="width:71px" %)Yes|(% style="width:140px" %)Heater|(% style="width:50px" %)HEA|(% style="width:191px" %)0x4030 sub 0x00, bit 11|(% style="width:194px" %)0x1020-0x1021, bit 11 50 +|(% style="width:188px" %)Init|(% style="width:474px" %)Signal showing that the device is in the initialization phase|(% style="width:62px" %)Yes*|(% style="width:71px" %)Yes*|(% style="width:140px" %)Init|(% style="width:50px" %)INI|(% style="width:191px" %)0x4030 sub 0x00, bit 0|(% style="width:194px" %)0x1020-0x1021, bit 0 51 +|(% style="width:188px" %)Interlock (modules)|(% style="width:474px" %)ORed internal signals "Interlock" from all battery modules|(% style="width:62px" %)Yes*|(% style="width:71px" %)Yes*|(% style="width:140px" %)Interlock (mod.)|(% style="width:50px" %)INM|(% style="width:191px" %)0x4030 sub 0x00, bit 7|(% style="width:194px" %)0x1020-0x1021, bit 7 52 +|(% style="width:188px" %)Main contactor|(% style="width:474px" %)Command to control the main contactor|(% style="width:62px" %)Yes|(% style="width:71px" %)Yes|(% style="width:140px" %)Main contactor|(% style="width:50px" %)MCO|(% style="width:191px" %)0x4030 sub 0x00, bit 13|(% style="width:194px" %)0x1020-0x1021, bit 13 53 +|(% style="width:188px" %)Precharging|(% style="width:474px" %)Command to control the precharging contactor|(% style="width:62px" %)Yes|(% style="width:71px" %)Yes|(% style="width:140px" %)Precharging|(% style="width:50px" %)PCH|(% style="width:191px" %)0x4030 sub 0x00, bit 6|(% style="width:194px" %)0x1020-0x1021, bit 6 54 +|(% style="width:188px" %)Service reset|(% style="width:474px" %)Command to restart the device|(% style="width:62px" %)Yes*|(% style="width:71px" %)Yes*|(% style="width:140px" %)Service reset|(% style="width:50px" %)SR|(% style="width:191px" %)0x4030 sub 0x00, bit 14|(% style="width:194px" %)0x1020-0x1021, bit 14 64 64 65 -Here is the list of error of BMS Main 3. 56 +(% class="wikigeneratedid" %) 57 +* Cannot be assigned to discrete outputs and relays. 66 66 67 -(% style="width:1177px" %) 68 -|(% style="width:171px" %)**Name **|(% style="width:67px" %)**Abbr.**|(% style="width:501px" %)**Description**|(% style="width:228px" %)**Set up by**|(% style="width:145px" %)**Is a Critical error?**|(% style="width:145px" %) 69 -|(% style="width:171px" %)Overcurrent|(% style="width:67px" %)OC|(% style="width:501px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %) 70 -|(% style="width:171px" %)Undervoltage|(% style="width:67px" %)UV|(% style="width:501px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 71 -|(% style="width:171px" %)Overvoltage|(% style="width:67px" %)OV|(% style="width:501px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 72 -|(% style="width:171px" %)Low temperature (DCH) |(% style="width:67px" %)LDT|(% style="width:501px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 73 -|(% style="width:171px" %)High temperature (DCH) |(% style="width:67px" %)HDT|(% style="width:501px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 74 -|(% style="width:171px" %)Battery cover error |(% style="width:67px" %)BC|(% style="width:501px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 75 -|(% style="width:171px" %)High humidity |(% style="width:67px" %)HH|(% style="width:501px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %) 76 -|(% style="width:171px" %)Water |(% style="width:67px" %)WA|(% style="width:501px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 77 -|(% style="width:171px" %)High Logic temperature |(% style="width:67px" %)LHT|(% style="width:501px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 78 -|(% style="width:171px" %)Logic offline |(% style="width:67px" %)LOF|(% style="width:501px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 79 -|(% style="width:171px" %)Critical error|(% style="width:67px" %)CRE|(% style="width:501px" %) |(% style="width:228px" %)Critical error|(% style="width:145px" %) |(% style="width:145px" %) 80 -|(% style="width:171px" %)Crown error |(% style="width:67px" %)CRO|(% style="width:501px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 81 -|(% style="width:171px" %)Cell count error |(% style="width:67px" %)CEL|(% style="width:501px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 82 -|(% style="width:171px" %)HYG offline |(% style="width:67px" %)HYG|(% style="width:501px" %) connection with a HYG forklift is lost;|(% style="width:228px" %)HYG Class I-III truck|(% style="width:145px" %) |(% style="width:145px" %) 83 -|(% style="width:171px" %)Need acknowledge |(% style="width:67px" %) |(% style="width:501px" %) there is an unacknowledged error in Error journal;|(% style="width:228px" %)Error journal|(% style="width:145px" %) |(% style="width:145px" %) 84 -|(% style="width:171px" %)Combilift offline |(% style="width:67px" %) |(% style="width:501px" %) connection with a Combilift forklift is lost;|(% style="width:228px" %)Combilift truck|(% style="width:145px" %) |(% style="width:145px" %) 85 -|(% style="width:171px" %)Short circuit|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Short circuit protection|(% style="width:145px" %) |(% style="width:145px" %) 86 -|(% style="width:171px" %)High contactor temperature|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)High contactor temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 87 -|(% style="width:171px" %)ADC error |(% style="width:67px" %) |(% style="width:501px" %) current cannot be measured;|(% style="width:228px" %) |(% style="width:145px" %)Yes|(% style="width:145px" %) 88 -|(% style="width:171px" %)Current sensor error |(% style="width:67px" %) |(% style="width:501px" %) error in the current sensor circuit;|(% style="width:228px" %)Current sensor protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 89 -|(% style="width:171px" %)CH contactor cycles error |(% style="width:67px" %) |(% style="width:501px" %) switching frequency of the charging contactor is too high;|(% style="width:228px" %)Charge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %) 90 -|(% style="width:171px" %)DCH contactor cycles error |(% style="width:67px" %) |(% style="width:501px" %) switching frequency of the discharging contactor is too high;|(% style="width:228px" %)Discharge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %) 91 -|(% style="width:171px" %)Shunt offline |(% style="width:67px" %) |(% style="width:501px" %) connection with the shunt current sensor is lost;|(% style="width:228px" %)Shunt sensor (CAN bus)|(% style="width:145px" %)Yes|(% style="width:145px" %) 92 -|(% style="width:171px" %)Shunt error |(% style="width:67px" %) |(% style="width:501px" %) internal error of the shunt current sensor;|(% style="width:228px" %)Shunt sensor (CAN bus)|(% style="width:145px" %)Yes|(% style="width:145px" %) 93 -|(% style="width:171px" %)WDT reset |(% style="width:67px" %) |(% style="width:501px" %) watchdog timer reset the device;|(% style="width:228px" %)WDT reset protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 94 -|(% style="width:171px" %)No temperature sensors |(% style="width:67px" %) |(% style="width:501px" %) the device has no temperature sensors connected;|(% style="width:228px" %)Temperature sensors protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 95 -|(% style="width:171px" %)Temperature sensor is shorted |(% style="width:67px" %) |(% style="width:501px" %) some temperature sensors are shorted;|(% style="width:228px" %)Temperature sensors protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 96 -|(% style="width:171px" %)Spirit offline |(% style="width:67px" %) |(% style="width:501px" %) connection with a Spirit forklift is lost;|(% style="width:228px" %)Spirit AGV truck|(% style="width:145px" %) |(% style="width:145px" %) 97 -|(% style="width:171px" %)Low temperature (CH) |(% style="width:67px" %) |(% style="width:501px" %) temperature is too low for charging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 98 -|(% style="width:171px" %)High temperature (CH) |(% style="width:67px" %) |(% style="width:501px" %) temperature is too high for charging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 99 -|(% style="width:171px" %)Unallowable charging |(% style="width:67px" %) |(% style="width:501px" %) charging the battery through the discharging contactor;|(% style="width:228px" %)Unallowable charging protection|(% style="width:145px" %) |(% style="width:145px" %) 100 -|(% style="width:171px" %)Stuck contactor|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Stuck contactor protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 101 -|(% style="width:171px" %)CH contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 102 -|(% style="width:171px" %)DCH contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 103 -|(% style="width:171px" %)Insulation fault;|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Insulation protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 104 -|(% style="width:171px" %)PCH contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 105 -|(% style="width:171px" %)CH/DCH contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 106 -|(% style="width:171px" %)Main contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 107 -|(% style="width:171px" %)General error|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)General error|(% style="width:145px" %) |(% style="width:145px" %) 108 -|(% style="width:171px" %)High voltage fault |(% style="width:67px" %) |(% style="width:501px" %) failure of high voltage measuring circuits;|(% style="width:228px" %)High voltage controller|(% style="width:145px" %)Yes|(% style="width:145px" %) 109 -|(% style="width:171px" %)Power switch error |(% style="width:67px" %) |(% style="width:501px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:228px" %) |(% style="width:145px" %)Yes|(% style="width:145px" %) 110 -|(% style="width:171px" %)HVIL error |(% style="width:67px" %) |(% style="width:501px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %)HVIL protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 111 -|(% style="width:171px" %)Precharge error |(% style="width:67px" %) |(% style="width:501px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:228px" %)Precharge controller|(% style="width:145px" %) |(% style="width:145px" %) 112 -|(% style="width:171px" %)Power fault |(% style="width:67px" %) |(% style="width:501px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:228px" %) |(% style="width:145px" %)Yes|(% style="width:145px" %) 113 -|(% style="width:171px" %)Current limit error |(% style="width:67px" %) |(% style="width:501px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:228px" %)Charge current limit protection, Discharge current limit protection|(% style="width:145px" %) |(% style="width:145px" %) 59 +== Errors == 114 114 61 +Below is the list of strings controller errors. 62 + 63 +* **Status values**: Off = 0, On = 1. 64 + 65 +(% style="width:1369px" %) 66 +|(% colspan="1" rowspan="2" style="width:223px" %)**Name **|(% colspan="1" rowspan="2" style="width:457px" %)**Description**|(% colspan="1" rowspan="2" style="width:42px" %)**Is a critical error?**|(% colspan="2" rowspan="1" style="width:131px" %)**Compability**|(% colspan="2" rowspan="1" style="width:172px" %)**BMS Display**|(% colspan="2" rowspan="1" style="width:326px" %)**Status** 67 +|=(% style="width: 64px;" %)**Main X**|=(% style="width: 66px;" %)**Main 3X**|=(% colspan="1" style="width: 128px;" %)Short name|=(% style="width: 43px;" %)Abbr.|(% colspan="1" style="width:167px" %)**CANopen SDO**|(% colspan="1" style="width:159px" %)**Modbus, input regs** 68 +|(% style="width:223px" %)ADC error|(% style="width:457px" %)Error of the ADC that measures the battery current|(% style="width:42px" %)Yes|(% style="width:64px" %) |(% style="width:66px" %)Yes|(% style="width:128px" %)ADC error|(% style="width:43px" %)ADC|(% style="width:167px" %)0x4020 sub 0x00, bit 23|(% style="width:159px" %)0x1022-0x1023, bit 23 69 +|(% style="width:223px" %)Battery cover error|(% style="width:457px" %)Battery cover is open|(% style="width:42px" %)Yes|(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Battery cover|(% style="width:43px" %)BCE|(% style="width:167px" %)0x4020 sub 0x00, bit 0|(% style="width:159px" %)0x1022-0x1023, bit 0 70 +|(% style="width:223px" %)CH contactor feedback error|(% style="width:457px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:42px" %)Yes|(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)CH cont. feed.|(% style="width:43px" %)CCF|(% style="width:167px" %)0x4020 sub 0x00, bit 10|(% style="width:159px" %)0x1022-0x1023, bit 10 71 +|(% style="width:223px" %)CH/DCH contactor feedback error|(% style="width:457px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:42px" %)Yes|(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)C/D cont. feed.|(% style="width:43px" %)CDF|(% style="width:167px" %)0x4020 sub 0x00, bit 12|(% style="width:159px" %)0x1022-0x1023, bit 12 72 +|(% style="width:223px" %)Charging current unbalance|(% style="width:457px" %)Charging currents of battery modules differ too much|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)CH current unb.|(% style="width:43px" %)CCU|(% style="width:167px" %)0x4020 sub 0x00, bit 7|(% style="width:159px" %)0x1022-0x1023, bit 7 73 +|(% style="width:223px" %)Critical error|(% style="width:457px" %)Critical system error, the BMS is damaged|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Critical error|(% style="width:43px" %)CER|(% style="width:167px" %)0x4020 sub 0x00, bit 2|(% style="width:159px" %)0x1022-0x1023, bit 2 74 +|(% style="width:223px" %)Current limit error|(% style="width:457px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Cur. limit error|(% style="width:43px" %)CLE|(% style="width:167px" %)0x4020 sub 0x00, bit 31|(% style="width:159px" %)0x1022-0x1023, bit 31 75 +|(% style="width:223px" %)Current sensor error|(% style="width:457px" %)Error in the current sensor circuit|(% style="width:42px" %)Yes|(% style="width:64px" %) |(% style="width:66px" %)Yes|(% style="width:128px" %)Current sensor|(% style="width:43px" %)CSE|(% style="width:167px" %)0x4020 sub 0x00, bit 24|(% style="width:159px" %)0x1022-0x1023, bit 24 76 +|(% style="width:223px" %)Current unbalance (CH)|(% style="width:457px" %)Some of battery modules are unbalanced in current (for charging)|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Current unb. CH|(% style="width:43px" %)CUC|(% style="width:167px" %)0x4020 sub 0x00, bit 5|(% style="width:159px" %)0x1022-0x1023, bit 5 77 +|(% style="width:223px" %)Current unbalance (DCH)|(% style="width:457px" %)Some of battery modules are unbalanced in current (for discharging)|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Current unb. DCH|(% style="width:43px" %)CUD|(% style="width:167px" %)0x4020 sub 0x00, bit 6|(% style="width:159px" %)0x1022-0x1023, bit 6 78 +|(% style="width:223px" %)DCH contactor feedback error|(% style="width:457px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:42px" %)Yes|(% style="width:64px" %) |(% style="width:66px" %)Yes|(% style="width:128px" %)DCH cont. feed.|(% style="width:43px" %)DCF|(% style="width:167px" %)0x4020 sub 0x00, bit 11|(% style="width:159px" %)0x1022-0x1023, bit 11 79 +|(% style="width:223px" %)Discharging current unbalance|(% style="width:457px" %)Discharging currents of battery modules differ too much|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)DCH current unb.|(% style="width:43px" %)DCU|(% style="width:167px" %)0x4020 sub 0x00, bit 8|(% style="width:159px" %)0x1022-0x1023, bit 8 80 +|(% style="width:223px" %)FS error|(% style="width:457px" %)SD card read/write error|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)FS error|(% style="width:43px" %)FSE|(% style="width:167px" %)0x4020 sub 0x00, bit 26|(% style="width:159px" %)0x1022-0x1023, bit 26 81 +|(% style="width:223px" %)High contactor temperature|(% style="width:457px" %)Temperature of a contactor is too high|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Hi. cont. temp.|(% style="width:43px" %)HCT|(% style="width:167px" %)0x4020 sub 0x00, bit 20|(% style="width:159px" %)0x1022-0x1023, bit 20 82 +|(% style="width:223px" %)High humidity|(% style="width:457px" %)Increased humidity inside the battery|(% style="width:42px" %) |(% style="width:64px" %) |(% style="width:66px" %)Yes|(% style="width:128px" %)High humidity|(% style="width:43px" %)HHU|(% style="width:167px" %)0x4020 sub 0x00, bit 17|(% style="width:159px" %)0x1022-0x1023, bit 17 83 +|(% style="width:223px" %)High voltage fault|(% style="width:457px" %)Failure of high voltage measuring circuits|(% style="width:42px" %)Yes|(% style="width:64px" %) |(% style="width:66px" %)Yes|(% style="width:128px" %)HV fault|(% style="width:43px" %)HVF|(% style="width:167px" %)0x4020 sub 0x00, bit 27|(% style="width:159px" %)0x1022-0x1023, bit 27 84 +|(% style="width:223px" %)HVIL error|(% style="width:457px" %)Breakage of high-voltage interlock current loop|(% style="width:42px" %)Yes|(% style="width:64px" %) |(% style="width:66px" %)Yes|(% style="width:128px" %)HVIL error|(% style="width:43px" %)HE|(% style="width:167px" %)0x4020 sub 0x00, bit 22|(% style="width:159px" %)0x1022-0x1023, bit 22 85 +|(% style="width:223px" %)Insulation fault|(% style="width:457px" %)Insulation resistance is too low|(% style="width:42px" %)Yes|(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Insulation fault|(% style="width:43px" %)INF|(% style="width:167px" %)0x4020 sub 0x00, bit 13|(% style="width:159px" %)0x1022-0x1023, bit 13 86 +|(% style="width:223px" %)Module offline|(% style="width:457px" %)Some of battery modules is offline|(% style="width:42px" %)Yes|(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Module offline|(% style="width:43px" %)MOF|(% style="width:167px" %)0x4020 sub 0x00, bit 1|(% style="width:159px" %)0x1022-0x1023, bit 1 87 +|(% style="width:223px" %)Main contactor feedback error|(% style="width:457px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:42px" %)Yes|(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Main cont. feed.|(% style="width:43px" %)MCF|(% style="width:167px" %)0x4020 sub 0x00, bit 29|(% style="width:159px" %)0x1022-0x1023, bit 29 88 +|(% style="width:223px" %)Mount error|(% style="width:457px" %)SD card cannot be mounted|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Mount error|(% style="width:43px" %)MNT|(% style="width:167px" %)0x4020 sub 0x00, bit 25|(% style="width:159px" %)0x1022-0x1023, bit 25 89 +|(% style="width:223px" %)Need acknowledge|(% style="width:457px" %)There is an unacknowledged error in error journal|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Need ACK|(% style="width:43px" %)ACK|(% style="width:167px" %)0x4020 sub 0x00, bit 9|(% style="width:159px" %)0x1022-0x1023, bit 9 90 +|(% style="width:223px" %)Overcurrent|(% style="width:457px" %)The battery current is too high|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Overcurrent|(% style="width:43px" %)OC|(% style="width:167px" %)0x4020 sub 0x00, bit 15|(% style="width:159px" %)0x1022-0x1023, bit 15 91 +|(% style="width:223px" %)PCH contactor feedback error|(% style="width:457px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:42px" %)Yes|(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)PCH cont. feed.|(% style="width:43px" %)PCF|(% style="width:167px" %)0x4020 sub 0x00, bit 28|(% style="width:159px" %)0x1022-0x1023, bit 28 92 +|(% style="width:223px" %)Power fault|(% style="width:457px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:42px" %)Yes|(% style="width:64px" %) |(% style="width:66px" %)Yes|(% style="width:128px" %)Power fault|(% style="width:43px" %)PF|(% style="width:167px" %)0x4021 sub 0x00, bit 0|(% style="width:159px" %)0x1038-0x1039, bit 0 93 +|(% style="width:223px" %)Power switch error|(% style="width:457px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:42px" %)Yes|(% style="width:64px" %) |(% style="width:66px" %)Yes|(% style="width:128px" %)PSW error|(% style="width:43px" %)PSE|(% style="width:167px" %)0x4020 sub 0x00, bit 16|(% style="width:159px" %)0x1022-0x1023, bit 16 94 +|(% style="width:223px" %)Precharge error|(% style="width:457px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Precharge error|(% style="width:43px" %)PE|(% style="width:167px" %)0x4020 sub 0x00, bit 30|(% style="width:159px" %)0x1022-0x1023, bit 30 95 +|(% style="width:223px" %)Short circuit|(% style="width:457px" %)Flowing high battery currents during a long time|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Short circuit|(% style="width:43px" %)SHC|(% style="width:167px" %)0x4020 sub 0x00, bit 19|(% style="width:159px" %)0x1022-0x1023, bit 19 96 +|(% style="width:223px" %)Stuck contactor|(% style="width:457px" %)Some contactor got stuck|(% style="width:42px" %)Yes|(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Stuck contactor|(% style="width:43px" %)STC|(% style="width:167px" %)0x4020 sub 0x00, bit 21|(% style="width:159px" %)0x1022-0x1023, bit 21 97 +|(% style="width:223px" %)Voltage unbalance (CH)|(% style="width:457px" %)Some of battery modules are unbalanced in voltage (for charging)|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Voltage unb. CH|(% style="width:43px" %)VUC|(% style="width:167px" %)0x4020 sub 0x00, bit 3|(% style="width:159px" %)0x1022-0x1023, bit 3 98 +|(% style="width:223px" %)Voltage unbalance (DCH)|(% style="width:457px" %)Some of battery modules are unbalanced in voltage (for discharging)|(% style="width:42px" %) |(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)Voltage unb. DCH|(% style="width:43px" %)VUD|(% style="width:167px" %)0x4020 sub 0x00, bit 4|(% style="width:159px" %)0x1022-0x1023, bit 4 99 +|(% style="width:223px" %)Water|(% style="width:457px" %)There is water in the battery enclosure|(% style="width:42px" %)Yes|(% style="width:64px" %) |(% style="width:66px" %)Yes|(% style="width:128px" %)Water|(% style="width:43px" %)WHU|(% style="width:167px" %)0x4020 sub 0x00, bit 18|(% style="width:159px" %)0x1022-0x1023, bit 18 100 +|(% style="width:223px" %)WDT reset|(% style="width:457px" %)Watchdog timer reset the device|(% style="width:42px" %)Yes|(% style="width:64px" %)Yes|(% style="width:66px" %)Yes|(% style="width:128px" %)WDT reset|(% style="width:43px" %)WDT|(% style="width:167px" %)0x4020 sub 0x00, bit 14|(% style="width:159px" %)0x1022-0x1023, bit 14 101 + 115 115