... ... @@ -23,7 +23,7 @@
23 23  |Join to discharge|(% style="width:360px" %)Request to join the battery modules for discharging|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Join to dischar.|(% style="width:63px" %)JTD|(% style="width:137px" %)0x5100 sub 0x0A|(% style="width:158px" %)0x5009|(% style="width:165px" %)0x4200 sub 0x01, bit 9|(% style="width:166px" %)0x103A-0x103B, bit 9
24 24  |Main contactor feedback|(% style="width:360px" %)Signal from the main contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Main cont. feed.|(% style="width:63px" %)MCF|(% style="width:137px" %)0x5100 sub 0x0C|(% style="width:158px" %)0x500B|(% style="width:165px" %)0x4200 sub 0x01, bit 11|(% style="width:166px" %)0x103A-0x103B, bit 11
25 25  |PCH contactor feedback|(% style="width:360px" %)Signal from the precharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)PCH cont. feed.|(% style="width:63px" %)PCF|(% style="width:137px" %)0x5100 sub 0x0B|(% style="width:158px" %)0x500A|(% style="width:165px" %)0x4200 sub 0x01, bit 10|(% style="width:166px" %)0x103A-0x103B, bit 10
26 -|Power down request|(% style="width:360px" %)Request to power down the device|(% style="width:62px" %) |(% style="width:76px" %)Yes|(% style="width:121px" %)Power down req.|(% style="width:63px" %)PDN|(% style="width:137px" %)0x5100 sub 0x0E|(% style="width:158px" %)-|(% style="width:165px" %)0x4200 sub 0x01, bit 13|(% style="width:166px" %)0x103A-0x103B, bit 13
26 +|Power down request|(% style="width:360px" %)Request to power down the device|(% style="width:62px" %) |(% style="width:76px" %)Yes|(% style="width:121px" %)Power down req.|(% style="width:63px" %)PDN|(% style="width:137px" %)0x5100 sub 0x0E|(% style="width:158px" %)0x500D|(% style="width:165px" %)0x4200 sub 0x01, bit 13|(% style="width:166px" %)0x103A-0x103B, bit 13
27 27  |Precharge request|(% style="width:360px" %)Request to close the precharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Precharge req.|(% style="width:63px" %)PRE|(% style="width:137px" %)0x5100 sub 0x03|(% style="width:158px" %)0x5002|(% style="width:165px" %)0x4200 sub 0x01, bit 2|(% style="width:166px" %)0x103A-0x103B, bit 2
28 28  
29 29  == Internal signals ==
... ... @@ -31,9 +31,9 @@
31 31  Below is the list of internal BMS signals. Most signals can be assigned to discrete outputs and relays.
32 32  
33 33  (% style="width:1498px" %)
34 -|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 355px;" %)**Description**|=(% colspan="2" rowspan="1" style="width: 138px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 182px;" %)BMS Display|=(% colspan="2" rowspan="1" style="width: 324px;" %)Status
35 -|=(% style="width: 62px;" %)**Main X**|=(% style="width: 76px;" %)**Main 3X**|=(% colspan="1" style="width: 119px;" %)Short name|=(% style="width: 62px;" %)Abbr.|=(% colspan="1" style="width: 324px;" %)**CANopen SDO**|=(% colspan="1" style="width: 296px;" %)**Modbus, input regs**
36 -|Charging current present|(% style="width:355px" %)Signal showing the presence of the charging current|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)CH curr. present|(% style="width:62px" %)CCP|(% style="width:324px" %) |(% style="width:296px" %)0x1020-0x1021, bit 3.
34 +|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 355px;" %)**Description**|=(% colspan="2" rowspan="1" style="width: 138px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 182px;" %)BMS Display|=(% colspan="1" rowspan="2" style="width: 324px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 296px;" %)**Modbus**
35 +|=(% style="width: 62px;" %)**Main X**|=(% style="width: 76px;" %)**Main 3X**|=(% colspan="1" style="width: 119px;" %)Short name|=(% style="width: 62px;" %)Abbr.
36 +|Charging current present|(% style="width:355px" %)Signal showing the presence of the charging current|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)CH curr. present|(% style="width:62px" %)CCP|(% style="width:324px" %) |(% style="width:296px" %)0x1020-0x1021, bit 3. Off = 0, On = 1.
37 37  |Charging|(% style="width:355px" %)Command to control the charging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Charging|(% style="width:62px" %)CH|(% style="width:324px" %) |(% style="width:296px" %)0x1020-0x1021, bit 1. Open = 0, Closed = 1.
38 38  |Charging/Discharging|(% style="width:355px" %)Command to control the charging/discharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Charg./Discharg.|(% style="width:62px" %)C/D|(% style="width:324px" %) |(% style="width:296px" %)0x1020-0x1021, bit 5. Open = 0, Closed = 1.
39 39  |Coolant pump|(% style="width:355px" %)Command to control the coolant pump|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Coolant pump|(% style="width:62px" %)CP|(% style="width:324px" %) |(% style="width:296px" %)0x1020-0x1021, bit 15. Off = 0, On = 1.