Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -13,7 +13,7 @@ 13 13 |=(% style="width: 62px;" %)**Main X**|=(% style="width: 76px;" %)**Main 3X**|=(% colspan="1" style="width: 121px;" %)Short name|=(% style="width: 63px;" %)Abbr.|=(% colspan="1" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" style="width: 158px;" %)**Modbus, holding regs**|=(% colspan="1" style="width: 165px;" %)**CANopen SDO**|=(% colspan="1" style="width: 166px;" %)**Modbus, input regs** 14 14 |Battery cover|(% style="width:360px" %)Signal from the battery cover|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Battery cover|(% style="width:63px" %)CVR|(% style="width:137px" %)0x5100 sub 0x01|(% style="width:158px" %)0x5000|(% style="width:165px" %)0x4200 sub 0x01, bit 0|(% style="width:166px" %)0x103A-0x103B, bit 0 15 15 |CH contactor feedback|(% style="width:360px" %)Signal from the charging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)CH cont. feed.|(% style="width:63px" %)CCF|(% style="width:137px" %)0x5100 sub 0x05|(% style="width:158px" %)0x5004|(% style="width:165px" %)0x4200 sub 0x01, bit 4|(% style="width:166px" %)0x103A-0x103B, bit 4 16 -|CH/DCH contactor feedback|(% style="width:360px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)C/D cont. feed.|(% style="width:63px" %)CDF|(% style="width:137px" %)0x5100 sub 0x07|(% style="width:158px" %) 16 +|CH/DCH contactor feedback|(% style="width:360px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)C/D cont. feed.|(% style="width:63px" %)CDF|(% style="width:137px" %)0x5100 sub 0x07|(% style="width:158px" %)0x5006|(% style="width:165px" %)0x4200 sub 0x01, bit 6|(% style="width:166px" %)0x103A-0x103B, bit 6 17 17 |Charge request|(% style="width:360px" %)Request to close the charging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Charge request|(% style="width:63px" %)CRE|(% style="width:137px" %)0x5100 sub 0x02|(% style="width:158px" %)0x5001|(% style="width:165px" %)0x4200 sub 0x01, bit 1|(% style="width:166px" %)0x103A-0x103B, bit 1 18 18 |DCH contactor feedback|(% style="width:360px" %)Signal from the discharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)DCH cont. feed.|(% style="width:63px" %)DCF|(% style="width:137px" %)0x5100 sub 0x06|(% style="width:158px" %)0x5005|(% style="width:165px" %)0x4200 sub 0x01, bit 5|(% style="width:166px" %)0x103A-0x103B, bit 5 19 19 |Discharge request|(% style="width:360px" %)Request to close the discharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Discharge req.|(% style="width:63px" %)DRE|(% style="width:137px" %)0x5100 sub 0x04|(% style="width:158px" %)0x5003|(% style="width:165px" %)0x4200 sub 0x01, bit 3|(% style="width:166px" %)0x103A-0x103B, bit 3