Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - Stringscontrollers: signals, states and errors1 +3.1 - Content
-
... ... @@ -1,94 +1,129 @@ 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 3 + 1 1 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Signals,states anderrors=5 +== General information == 3 3 4 -== Input signals ==7 +=== List of input signals === 5 5 6 - Belowis the list ofinput signals that canbeassignedtodiscreteinputs ofthebattery stringscontroller.9 +Here is the list of available input signals of BMS Main 3. 7 7 8 -(% style="width:1497px" %) 9 -|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 360px;" %)**Description**|=(% colspan="2" rowspan="1" style="width: 140px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 184px;" %)BMS DIsplay|=(% colspan="1" rowspan="2" style="width: 327px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 299px;" %)**Modbus** 10 -|=(% style="width: 62px;" %)**Main X**|=(% style="width: 76px;" %)**Main 3X**|=(% colspan="1" style="width: 121px;" %)Short name|=(% style="width: 63px;" %)Abbr. 11 -|Battery cover|(% style="width:360px" %)Signal from the battery cover|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Battery cover|(% style="width:63px" %)CVR|(% style="width:327px" %) |(% style="width:299px" %) 12 -|CH contactor feedback|(% style="width:360px" %)Signal from the charging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)CH cont. feed.|(% style="width:63px" %)CCF|(% style="width:327px" %) |(% style="width:299px" %) 13 -|CH/DCH contactor feedback|(% style="width:360px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)C/D cont. feed.|(% style="width:63px" %)CDF|(% style="width:327px" %) |(% style="width:299px" %) 14 -|Charge request|(% style="width:360px" %)Request to close the charging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Charge request|(% style="width:63px" %)CRE|(% style="width:327px" %) |(% style="width:299px" %) 15 -|DCH contactor feedback|(% style="width:360px" %)Signal from the discharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)DCH cont. feed.|(% style="width:63px" %)DCF|(% style="width:327px" %) |(% style="width:299px" %) 16 -|Discharge request|(% style="width:360px" %)Request to close the discharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Discharge req.|(% style="width:63px" %)DRE|(% style="width:327px" %) |(% style="width:299px" %) 17 -|Insulation status|(% style="width:360px" %)Signal from an insulation monitoring device|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Insul. status|(% style="width:63px" %)INS|(% style="width:327px" %) |(% style="width:299px" %) 18 -|Interlock|(% style="width:360px" %)Signal from the interlock loop|(% style="width:62px" %) |(% style="width:76px" %)Yes|(% style="width:121px" %)Interlock|(% style="width:63px" %)INT|(% style="width:327px" %) |(% style="width:299px" %) 19 -|Join to charge|(% style="width:360px" %)Request to join the battery modules for charging|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Join to charge|(% style="width:63px" %)JTC|(% style="width:327px" %) |(% style="width:299px" %) 20 -|Join to discharge|(% style="width:360px" %)Request to join the battery modules for discharging|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Join to dischar.|(% style="width:63px" %)JTD|(% style="width:327px" %) |(% style="width:299px" %) 21 -|Main contactor feedback|(% style="width:360px" %)Signal from the main contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Main cont. feed.|(% style="width:63px" %)MCF|(% style="width:327px" %) |(% style="width:299px" %) 22 -|PCH contactor feedback|(% style="width:360px" %)Signal from the precharging contactor feedback loop|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)PCH cont. feed.|(% style="width:63px" %)PCF|(% style="width:327px" %) |(% style="width:299px" %) 23 -|Power down request|(% style="width:360px" %)Request to power down the device|(% style="width:62px" %) |(% style="width:76px" %)Yes|(% style="width:121px" %)Power down req.|(% style="width:63px" %)PDN|(% style="width:327px" %) |(% style="width:299px" %) 24 -|Precharge request|(% style="width:360px" %)Request to close the precharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:121px" %)Precharge req.|(% style="width:63px" %)PRE|(% style="width:327px" %) |(% style="width:299px" %) 11 +(% style="width:1274px" %) 12 +|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 483px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 248px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus** 13 +|=(% style="width: 98px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3** 14 +|Balancing request |BR|a request to balance the cells;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 15 +|Battery cover |CVR|a signal from the battery cover;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 16 +|CH contactor feedback |CCF|a signal from charging contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 17 +|CH/DCH contactor feedback |CDF|a signal from charging/discharging contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 18 +|Charge request |CRE|a request to close the charging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 19 +|Charger connected |CON|a signal indicating that charger is connected;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 20 +|Circuit breaker status |CBS|status of protection disconnector;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 21 +|Close External 1 |CE1|a request to close the External 1 discrete output (if assigned).|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 22 +|Close Main contactor |CMC|a request to close the main contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 23 +|DCH contactor feedback |DCF|a signal from discharging contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 24 +|Discharge request |DRE|a request to close the discharging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 25 +|Fuse 1|F1|signal from fuse 1;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 26 +|Fuse 2|F2|signal from fuse 2;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 27 +|Fuse 3 |F3|signal from fuse 3;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 +|Inhibit charging |ICH|a command to open the charging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 +|Inhibit discharging |IDC|a command to open the discharging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 +|Insulation status |INS|a signal from an insulation monitoring device;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 31 +|Interlock | |a signal from interlock loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 32 +|Main contactor feedback |MCF|a signal from main contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 33 +|PCH contactor feedback |PCF|a signal from precharging contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 34 +|Power up/down request |PDN|a request to power down the device;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 25 25 26 -== Internal signals ==36 +=== List of internal states === 27 27 28 - Belowis the list ofinternal BMS signals. Most signals canbeassignedto discrete outputsandrelays.38 +Here is the list of available internal states of BMS Main 3. 29 29 30 -(% style="width:1498px" %) 31 -|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 355px;" %)**Description**|=(% colspan="2" rowspan="1" style="width: 138px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 182px;" %)BMS Display|=(% colspan="1" rowspan="2" style="width: 324px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 296px;" %)**Modbus** 32 -|=(% style="width: 62px;" %)**Main X**|=(% style="width: 76px;" %)**Main 3X**|=(% colspan="1" style="width: 119px;" %)Short name|=(% style="width: 62px;" %)Abbr. 33 -|Charging current present|(% style="width:355px" %)Signal showing the presence of the charging current|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)CH curr. present|(% style="width:62px" %)CCP|(% style="width:324px" %) |(% style="width:296px" %) 34 -|Charging|(% style="width:355px" %)Command to control the charging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Charging|(% style="width:62px" %)CH|(% style="width:324px" %) |(% style="width:296px" %) 35 -|Charging/Discharging|(% style="width:355px" %)Command to control the charging/discharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Charg./Discharg.|(% style="width:62px" %)C/D|(% style="width:324px" %) |(% style="width:296px" %) 36 -|Coolant pump|(% style="width:355px" %)Command to control the coolant pump|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Coolant pump|(% style="width:62px" %)CP|(% style="width:324px" %) |(% style="width:296px" %) 37 -|Cooler|(% style="width:355px" %)Command to control the cooler|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Cooler|(% style="width:62px" %)COO|(% style="width:324px" %) |(% style="width:296px" %) 38 -|Discharging current present|(% style="width:355px" %)Signal showing the presence of the discharging current|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)DCH cur. present|(% style="width:62px" %)DCP|(% style="width:324px" %) |(% style="width:296px" %) 39 -|Discharging|(% style="width:355px" %)Command to control the discharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Discharging|(% style="width:62px" %)DCH|(% style="width:324px" %) |(% style="width:296px" %) 40 -|Fuse 1 (modules)|(% style="width:355px" %)ORed internal signals "Fuse 1" from all battery modules|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)Fuse 1 (mod.)|(% style="width:62px" %)F1M|(% style="width:324px" %) |(% style="width:296px" %) 41 -|Fuse 2 (modules)|(% style="width:355px" %)ORed internal signals "Fuse 2" from all battery modules|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)Fuse 2 (mod.)|(% style="width:62px" %)F2M|(% style="width:324px" %) |(% style="width:296px" %) 42 -|Fuse 3 (modules)|(% style="width:355px" %)ORed internal signals "Fuse 3" from all battery modules|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)Fuse 3 (mod.)|(% style="width:62px" %)F3M|(% style="width:324px" %) |(% style="width:296px" %) 43 -|General error (modules)|(% style="width:355px" %)ORed internal signals "General error" from all battery modules|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Gen.error (mod.)|(% style="width:62px" %)GEM|(% style="width:324px" %) |(% style="width:296px" %) 44 -|Heater|(% style="width:355px" %)Command to control the heater|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Heater|(% style="width:62px" %)HEA|(% style="width:324px" %) |(% style="width:296px" %) 45 -|Init|(% style="width:355px" %)Signal showing that the device is in the initialization phase|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)Init|(% style="width:62px" %)INI|(% style="width:324px" %) |(% style="width:296px" %) 46 -|Interlock (modules)|(% style="width:355px" %)ORed internal signals "Interlock" from all battery modules|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)Interlock (mod.)|(% style="width:62px" %)INM|(% style="width:324px" %) |(% style="width:296px" %) 47 -|Main contactor|(% style="width:355px" %)Command to control the main contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Main contactor|(% style="width:62px" %)MCO|(% style="width:324px" %) |(% style="width:296px" %) 48 -|Precharging|(% style="width:355px" %)Command to control the precharging contactor|(% style="width:62px" %)Yes|(% style="width:76px" %)Yes|(% style="width:119px" %)Precharging|(% style="width:62px" %)PCH|(% style="width:324px" %) |(% style="width:296px" %) 49 -|Service reset|(% style="width:355px" %)Command to restart the device|(% style="width:62px" %)Yes*|(% style="width:76px" %)Yes*|(% style="width:119px" %)Service reset|(% style="width:62px" %)SR|(% style="width:324px" %) |(% style="width:296px" %) 40 +(% style="width:1277px" %) 41 +|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 42 +|=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 43 +|Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 44 +|Balancing 1 |BA1|balancing the first series of cells;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 45 +|Balancing 2 |BA2|balancing the second series of cells;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 46 +|Cell analysis|CEA| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 47 +|Charging current present |CCP|the presence of the charging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 48 +|Charging |CH|state of the charging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 +|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 +|Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 51 +|Crown EWS|EWS| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 52 +|Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 +|Discharging current present |DCP|the presence of the discharging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 54 +|Discharging |DCH|state of the discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 55 +|External 1 |EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 56 +|Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 +|High charging current |HCC|charging current is high;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 +|Init|INI| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 59 +|Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 60 +|Main contactor |MCO|state of the main contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 61 +|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 +|Power up |PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 +|Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 64 +|Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 65 +|Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 66 +|Service reset|SR| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 67 +|Shutdown request (Combilift)|CSH| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 68 +|Shutdown request (HYG/Spirit)|HSH| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 69 +|Voltage too high for charging|ENV| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 50 50 51 -(% class="wikigeneratedid" %) 52 -* Cannot be assigned to discrete outputs and relays. 71 +=== List of errors === 53 53 73 +Here is the list of error of BMS Main 3. 54 54 55 -== Errors == 75 +(% style="width:1279px" %) 76 +|(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:58px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus** 77 +|=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3** 78 +|(% style="width:196px" %)Overcurrent|(% style="width:58px" %)OC|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 79 +|(% style="width:196px" %)Undervoltage|(% style="width:58px" %)UV|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 80 +|(% style="width:196px" %)Overvoltage|(% style="width:58px" %)OV|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 81 +|(% style="width:196px" %)Low temperature (DCH) |(% style="width:58px" %)LDT|(% style="width:443px" %)temperature is too low for discharging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 82 +|(% style="width:196px" %)High temperature (DCH) |(% style="width:58px" %)HDT|(% style="width:443px" %)temperature is too high for discharging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 83 +|(% style="width:196px" %)Battery cover error |(% style="width:58px" %)BC|(% style="width:443px" %)battery cover is open;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 84 +|(% style="width:196px" %)High humidity |(% style="width:58px" %)HH|(% style="width:443px" %)humidity of the battery is increased;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 85 +|(% style="width:196px" %)Water |(% style="width:58px" %)WA|(% style="width:443px" %)there is water in the battery enclosure;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 86 +|(% style="width:196px" %)High Logic temperature |(% style="width:58px" %)LHT|(% style="width:443px" %)at least one of the Logic devices is overheated;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 87 +|(% style="width:196px" %)Logic offline |(% style="width:58px" %)LOF|(% style="width:443px" %)at least one of the Logic devices is offline;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 88 +|(% style="width:196px" %)Critical error|(% style="width:58px" %)CER|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 89 +|(% style="width:196px" %)Crown error |(% style="width:58px" %)CRO|(% style="width:443px" %)connection with a Crown forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 90 +|(% style="width:196px" %)Cell count error |(% style="width:58px" %)CEL|(% style="width:443px" %)number of cells does not match the specified value;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 91 +|(% style="width:196px" %)HYG offline |(% style="width:58px" %)HYG|(% style="width:443px" %)connection with a HYG forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 +|(% style="width:196px" %)Need acknowledge |(% style="width:58px" %)ACK|(% style="width:443px" %)there is an unacknowledged error in Error journal;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 +|(% style="width:196px" %)Combilift offline |(% style="width:58px" %)COM|(% style="width:443px" %)connection with a Combilift forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 94 +|(% style="width:196px" %)Short circuit|(% style="width:58px" %)SHC|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 95 +|(% style="width:196px" %)High contactor temperature|(% style="width:58px" %)CHT|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 96 +|(% style="width:196px" %)Logic count error|(% style="width:58px" %)LOG|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 97 +|(% style="width:196px" %)ADC error |(% style="width:58px" %)ADC|(% style="width:443px" %)current cannot be measured;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 98 +|(% style="width:196px" %)Current sensor error |(% style="width:58px" %)CSE|(% style="width:443px" %)error in the current sensor circuit;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 +|(% style="width:196px" %)CH contactor cycles error |(% style="width:58px" %)CCC|(% style="width:443px" %)switching frequency of the charging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 +|(% style="width:196px" %)DCH contactor cycles error |(% style="width:58px" %)DCC|(% style="width:443px" %)switching frequency of the discharging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 101 +|(% style="width:196px" %)Shunt offline |(% style="width:58px" %)SHO|(% style="width:443px" %)connection with the shunt current sensor is lost;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 +|(% style="width:196px" %)Shunt error |(% style="width:58px" %)SHE|(% style="width:443px" %)internal error of the shunt current sensor;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 +|(% style="width:196px" %)Settings error|(% style="width:58px" %)SET|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 104 +|(% style="width:196px" %)WDT reset |(% style="width:58px" %)WDT|(% style="width:443px" %)watchdog timer reset the device;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 105 +|(% style="width:196px" %)No temperature sensors |(% style="width:58px" %)NTS|(% style="width:443px" %)the device has no temperature sensors connected;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 106 +|(% style="width:196px" %)Temperature sensor is shorted |(% style="width:58px" %)TSS|(% style="width:443px" %)some temperature sensors are shorted;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 +|(% style="width:196px" %)Spirit offline |(% style="width:58px" %)SPI|(% style="width:443px" %)connection with a Spirit forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 +|(% style="width:196px" %)Mount error|(% style="width:58px" %)MNT|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 +|(% style="width:196px" %)FS error|(% style="width:58px" %)FSE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 110 +|(% style="width:196px" %)Low temperature (CH) |(% style="width:58px" %)LCT|(% style="width:443px" %)temperature is too low for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 +|(% style="width:196px" %)High temperature (CH) |(% style="width:58px" %)HCT|(% style="width:443px" %)temperature is too high for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 112 +|(% style="width:196px" %)Unallowable charging |(% style="width:58px" %)UCH|(% style="width:443px" %)charging the battery through the discharging contactor;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 113 +|(% style="width:196px" %)Stuck contactor|(% style="width:58px" %)STC|(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 114 +|(% style="width:196px" %)CH contactor feedback error |(% style="width:58px" %)CCF|(% style="width:443px" %)the control signals for the charging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 115 +|(% style="width:196px" %)DCH contactor feedback error |(% style="width:58px" %)DCF|(% style="width:443px" %)the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 116 +|(% style="width:196px" %)Insulation fault;|(% style="width:58px" %)INF|(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 117 +|(% style="width:196px" %)PCH contactor feedback error |(% style="width:58px" %)PCF|(% style="width:443px" %)the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 118 +|(% style="width:196px" %)CH/DCH contactor feedback error |(% style="width:58px" %)CDF|(% style="width:443px" %)the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 119 +|(% style="width:196px" %)Main contactor feedback error |(% style="width:58px" %)MCF|(% style="width:443px" %)the control signals for the main contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 120 +|(% style="width:196px" %)Contactor feedback error|(% style="width:58px" %)CFE|(% style="width:443px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 121 +|(% style="width:196px" %)General error|(% style="width:58px" %)GE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 122 +|(% style="width:196px" %)High voltage fault |(% style="width:58px" %)HVF|(% style="width:443px" %)failure of high voltage measuring circuits;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 123 +|(% style="width:196px" %)Power switch error |(% style="width:58px" %)PSE|(% style="width:443px" %)short circuit in contactor coil control circuit or power switch overheating;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 +|(% style="width:196px" %)HVIL error |(% style="width:58px" %)HE|(% style="width:443px" %)breakage of high-voltage interlock current loop;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 125 +|(% style="width:196px" %)Precharge error |(% style="width:58px" %)PE|(% style="width:443px" %)capacitive load pre-charge process did not end during the estimated time;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 126 +|(% style="width:196px" %)Power fault |(% style="width:58px" %)PF|(% style="width:443px" %)external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 127 +|(% style="width:196px" %)Current limit error |(% style="width:58px" %)CLE|(% style="width:443px" %)charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 56 56 57 -(% style="width:1500px" %) 58 -|(% colspan="1" rowspan="2" style="width:200px" %)**Name **|(% colspan="1" rowspan="2" style="width:365px" %)**Description**|(% colspan="1" rowspan="2" style="width:65px" %)**Is a critical error?**|(% colspan="2" rowspan="1" style="width:152px" %)**Compability**|(% colspan="2" rowspan="1" style="width:142px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:161px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:300px" %)**Modbus** 59 -|=(% style="width: 63px;" %)**Main X**|=(% style="width: 81px;" %)**Main 3X**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation 60 -|(% style="width:200px" %)ADC error|(% style="width:365px" %)Error of the ADC that measures the battery current|(% style="width:65px" %)Yes|(% style="width:63px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)ADC error|ADC|(% style="width:161px" %) |(% style="width:300px" %) 61 -|(% style="width:200px" %)Battery cover error|(% style="width:365px" %)Battery cover is open|(% style="width:65px" %)Yes|(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Battery cover|BCE|(% style="width:161px" %) |(% style="width:300px" %) 62 -|(% style="width:200px" %)CH contactor feedback error|(% style="width:365px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:65px" %)Yes|(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)CH cont. feed.|CCF|(% style="width:161px" %) |(% style="width:300px" %) 63 -|(% style="width:200px" %)CH/DCH contactor feedback error|(% style="width:365px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:65px" %)Yes|(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)C/D cont. feed.|CDF|(% style="width:161px" %) |(% style="width:300px" %) 64 -|(% style="width:200px" %)Charging current unbalance|(% style="width:365px" %)Charging currents of battery modules differ too much|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)CH current unb.|CCU|(% style="width:161px" %) |(% style="width:300px" %) 65 -|(% style="width:200px" %)Critical error|(% style="width:365px" %)Critical system error, the BMS is damaged|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Critical error|CER|(% style="width:161px" %) |(% style="width:300px" %) 66 -|(% style="width:200px" %)Current limit error|(% style="width:365px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Cur. limit error|CLE|(% style="width:161px" %) |(% style="width:300px" %) 67 -|(% style="width:200px" %)Current sensor error|(% style="width:365px" %)Error in the current sensor circuit|(% style="width:65px" %)Yes|(% style="width:63px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)Current sensor|CSE|(% style="width:161px" %) |(% style="width:300px" %) 68 -|(% style="width:200px" %)Current unbalance (CH)|(% style="width:365px" %)Some of battery modules are unbalanced in current (for charging)|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Current unb. CH|CUC|(% style="width:161px" %) |(% style="width:300px" %) 69 -|(% style="width:200px" %)Current unbalance (DCH)|(% style="width:365px" %)Some of battery modules are unbalanced in current (for discharging)|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Current unb. DCH|CUD|(% style="width:161px" %) |(% style="width:300px" %) 70 -|(% style="width:200px" %)DCH contactor feedback error|(% style="width:365px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:65px" %)Yes|(% style="width:63px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)DCH cont. feed.|DCF|(% style="width:161px" %) |(% style="width:300px" %) 71 -|(% style="width:200px" %)Discharging current unbalance|(% style="width:365px" %)Discharging currents of battery modules differ too much|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)DCH current unb.|DCU|(% style="width:161px" %) |(% style="width:300px" %) 72 -|(% style="width:200px" %)FS error|(% style="width:365px" %)SD card read/write error|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)FS error|FSE|(% style="width:161px" %) |(% style="width:300px" %) 73 -|(% style="width:200px" %)High contactor temperature|(% style="width:365px" %)Temperature of a contactor is too high|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Hi. cont. temp.|HCT|(% style="width:161px" %) |(% style="width:300px" %) 74 -|(% style="width:200px" %)High humidity|(% style="width:365px" %)Increased humidity inside the battery|(% style="width:65px" %) |(% style="width:63px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)High humidity|HHU|(% style="width:161px" %) |(% style="width:300px" %) 75 -|(% style="width:200px" %)High voltage fault|(% style="width:365px" %)Failure of high voltage measuring circuits|(% style="width:65px" %)Yes|(% style="width:63px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)HV fault|HVF|(% style="width:161px" %) |(% style="width:300px" %) 76 -|(% style="width:200px" %)HVIL error|(% style="width:365px" %)Breakage of high-voltage interlock current loop|(% style="width:65px" %)Yes|(% style="width:63px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)HVIL error|HE|(% style="width:161px" %) |(% style="width:300px" %) 77 -|(% style="width:200px" %)Insulation fault|(% style="width:365px" %)Insulation resistance is too low|(% style="width:65px" %)Yes|(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Insulation fault|INF|(% style="width:161px" %) |(% style="width:300px" %) 78 -|(% style="width:200px" %)Module offline|(% style="width:365px" %)Some of battery modules is offline|(% style="width:65px" %)Yes|(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Module offline|MOF|(% style="width:161px" %) |(% style="width:300px" %) 79 -|(% style="width:200px" %)Main contactor feedback error|(% style="width:365px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:65px" %)Yes|(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Main cont. feed.|MCF|(% style="width:161px" %) |(% style="width:300px" %) 80 -|(% style="width:200px" %)Mount error|(% style="width:365px" %)SD card cannot be mounted|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Mount error|MNT|(% style="width:161px" %) |(% style="width:300px" %) 81 -|(% style="width:200px" %)Need acknowledge|(% style="width:365px" %)There is an unacknowledged error in error journal|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Need ACK|ACK|(% style="width:161px" %) |(% style="width:300px" %) 82 -|(% style="width:200px" %)Overcurrent|(% style="width:365px" %)The battery current is too high|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Overcurrent|OC|(% style="width:161px" %) |(% style="width:300px" %) 83 -|(% style="width:200px" %)PCH contactor feedback error|(% style="width:365px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:65px" %)Yes|(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)PCH cont. feed.|PCF|(% style="width:161px" %) |(% style="width:300px" %) 84 -|(% style="width:200px" %)Power fault|(% style="width:365px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:65px" %)Yes|(% style="width:63px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)Power fault|PF|(% style="width:161px" %) |(% style="width:300px" %) 85 -|(% style="width:200px" %)Power switch error|(% style="width:365px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:65px" %)Yes|(% style="width:63px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)PSW error|PSE|(% style="width:161px" %) |(% style="width:300px" %) 86 -|(% style="width:200px" %)Precharge error|(% style="width:365px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Precharge error|PE|(% style="width:161px" %) |(% style="width:300px" %) 87 -|(% style="width:200px" %)Short circuit|(% style="width:365px" %)Flowing high battery currents during a long time|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Short circuit|SHC|(% style="width:161px" %) |(% style="width:300px" %) 88 -|(% style="width:200px" %)Stuck contactor|(% style="width:365px" %)Some contactor got stuck|(% style="width:65px" %)Yes|(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Stuck contactor|STC|(% style="width:161px" %) |(% style="width:300px" %) 89 -|(% style="width:200px" %)Voltage unbalance (CH)|(% style="width:365px" %)Some of battery modules are unbalanced in voltage (for charging)|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Voltage unb. CH|VUC|(% style="width:161px" %) |(% style="width:300px" %) 90 -|(% style="width:200px" %)Voltage unbalance (DCH)|(% style="width:365px" %)Some of battery modules are unbalanced in voltage (for discharging)|(% style="width:65px" %) |(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Voltage unb. DCH|VUD|(% style="width:161px" %) |(% style="width:300px" %) 91 -|(% style="width:200px" %)Water|(% style="width:365px" %)There is water in the battery enclosure|(% style="width:65px" %)Yes|(% style="width:63px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)Water|WHU|(% style="width:161px" %) |(% style="width:300px" %) 92 -|(% style="width:200px" %)WDT reset|(% style="width:365px" %)Watchdog timer reset the device|(% style="width:65px" %)Yes|(% style="width:63px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)WDT reset|WDT|(% style="width:161px" %) |(% style="width:300px" %) 93 - 94 94