Last modified by Admin on 2025/02/21 14:51

From version 33.19
edited by Admin
on 2025/02/04 12:14
Change comment: There is no comment for this version
To version 33.20
edited by Admin
on 2025/02/04 12:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -62,27 +62,27 @@
62 62  |(% style="width:200px" %)CH/DCH contactor feedback error|(% style="width:365px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:63px" %)Yes|(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)C/D cont. feed.|(% style="width:54px" %)CDF|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 12. Off = 0, On = 1.
63 63  |(% style="width:200px" %)Charging current unbalance|(% style="width:365px" %)Charging currents of battery modules differ too much|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)CH current unb.|(% style="width:54px" %)CCU|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 7. Off = 0, On = 1.
64 64  |(% style="width:200px" %)Critical error|(% style="width:365px" %)Critical system error, the BMS is damaged|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Critical error|(% style="width:54px" %)CER|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 2. Off = 0, On = 1.
65 -|(% style="width:200px" %)Current limit error|(% style="width:365px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Cur. limit error|(% style="width:54px" %)CLE|(% style="width:266px" %) |(% style="width:294px" %)
65 +|(% style="width:200px" %)Current limit error|(% style="width:365px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Cur. limit error|(% style="width:54px" %)CLE|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 31. Off = 0, On = 1.
66 66  |(% style="width:200px" %)Current sensor error|(% style="width:365px" %)Error in the current sensor circuit|(% style="width:63px" %)Yes|(% style="width:66px" %) |(% style="width:70px" %)Yes|(% style="width:121px" %)Current sensor|(% style="width:54px" %)CSE|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 24. Off = 0, On = 1.
67 67  |(% style="width:200px" %)Current unbalance (CH)|(% style="width:365px" %)Some of battery modules are unbalanced in current (for charging)|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Current unb. CH|(% style="width:54px" %)CUC|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 5. Off = 0, On = 1.
68 68  |(% style="width:200px" %)Current unbalance (DCH)|(% style="width:365px" %)Some of battery modules are unbalanced in current (for discharging)|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Current unb. DCH|(% style="width:54px" %)CUD|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 6. Off = 0, On = 1.
69 69  |(% style="width:200px" %)DCH contactor feedback error|(% style="width:365px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:63px" %)Yes|(% style="width:66px" %) |(% style="width:70px" %)Yes|(% style="width:121px" %)DCH cont. feed.|(% style="width:54px" %)DCF|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 11. Off = 0, On = 1.
70 70  |(% style="width:200px" %)Discharging current unbalance|(% style="width:365px" %)Discharging currents of battery modules differ too much|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)DCH current unb.|(% style="width:54px" %)DCU|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 8. Off = 0, On = 1.
71 -|(% style="width:200px" %)FS error|(% style="width:365px" %)SD card read/write error|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)FS error|(% style="width:54px" %)FSE|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 12. Off = 0, On = 1.
71 +|(% style="width:200px" %)FS error|(% style="width:365px" %)SD card read/write error|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)FS error|(% style="width:54px" %)FSE|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 26. Off = 0, On = 1.
72 72  |(% style="width:200px" %)High contactor temperature|(% style="width:365px" %)Temperature of a contactor is too high|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Hi. cont. temp.|(% style="width:54px" %)HCT|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 20. Off = 0, On = 1.
73 73  |(% style="width:200px" %)High humidity|(% style="width:365px" %)Increased humidity inside the battery|(% style="width:63px" %) |(% style="width:66px" %) |(% style="width:70px" %)Yes|(% style="width:121px" %)High humidity|(% style="width:54px" %)HHU|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 17. Off = 0, On = 1.
74 -|(% style="width:200px" %)High voltage fault|(% style="width:365px" %)Failure of high voltage measuring circuits|(% style="width:63px" %)Yes|(% style="width:66px" %) |(% style="width:70px" %)Yes|(% style="width:121px" %)HV fault|(% style="width:54px" %)HVF|(% style="width:266px" %) |(% style="width:294px" %)
74 +|(% style="width:200px" %)High voltage fault|(% style="width:365px" %)Failure of high voltage measuring circuits|(% style="width:63px" %)Yes|(% style="width:66px" %) |(% style="width:70px" %)Yes|(% style="width:121px" %)HV fault|(% style="width:54px" %)HVF|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 27. Off = 0, On = 1.
75 75  |(% style="width:200px" %)HVIL error|(% style="width:365px" %)Breakage of high-voltage interlock current loop|(% style="width:63px" %)Yes|(% style="width:66px" %) |(% style="width:70px" %)Yes|(% style="width:121px" %)HVIL error|(% style="width:54px" %)HE|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 22. Off = 0, On = 1.
76 76  |(% style="width:200px" %)Insulation fault|(% style="width:365px" %)Insulation resistance is too low|(% style="width:63px" %)Yes|(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 13. Off = 0, On = 1.
77 77  |(% style="width:200px" %)Module offline|(% style="width:365px" %)Some of battery modules is offline|(% style="width:63px" %)Yes|(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Module offline|(% style="width:54px" %)MOF|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 1. Off = 0, On = 1.
78 -|(% style="width:200px" %)Main contactor feedback error|(% style="width:365px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:63px" %)Yes|(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Main cont. feed.|(% style="width:54px" %)MCF|(% style="width:266px" %) |(% style="width:294px" %)
78 +|(% style="width:200px" %)Main contactor feedback error|(% style="width:365px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:63px" %)Yes|(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Main cont. feed.|(% style="width:54px" %)MCF|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 29. Off = 0, On = 1.
79 79  |(% style="width:200px" %)Mount error|(% style="width:365px" %)SD card cannot be mounted|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Mount error|(% style="width:54px" %)MNT|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 25. Off = 0, On = 1.
80 80  |(% style="width:200px" %)Need acknowledge|(% style="width:365px" %)There is an unacknowledged error in error journal|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Need ACK|(% style="width:54px" %)ACK|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 9. Off = 0, On = 1.
81 81  |(% style="width:200px" %)Overcurrent|(% style="width:365px" %)The battery current is too high|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Overcurrent|(% style="width:54px" %)OC|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 15. Off = 0, On = 1.
82 -|(% style="width:200px" %)PCH contactor feedback error|(% style="width:365px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:63px" %)Yes|(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)PCH cont. feed.|(% style="width:54px" %)PCF|(% style="width:266px" %) |(% style="width:294px" %)
83 -|(% style="width:200px" %)Power fault|(% style="width:365px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:63px" %)Yes|(% style="width:66px" %) |(% style="width:70px" %)Yes|(% style="width:121px" %)Power fault|(% style="width:54px" %)PF|(% style="width:266px" %) |(% style="width:294px" %)
82 +|(% style="width:200px" %)PCH contactor feedback error|(% style="width:365px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:63px" %)Yes|(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)PCH cont. feed.|(% style="width:54px" %)PCF|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 28. Off = 0, On = 1.
83 +|(% style="width:200px" %)Power fault|(% style="width:365px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:63px" %)Yes|(% style="width:66px" %) |(% style="width:70px" %)Yes|(% style="width:121px" %)Power fault|(% style="width:54px" %)PF|(% style="width:266px" %) |(% style="width:294px" %)**0x1038-0x1039**
84 84  |(% style="width:200px" %)Power switch error|(% style="width:365px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:63px" %)Yes|(% style="width:66px" %) |(% style="width:70px" %)Yes|(% style="width:121px" %)PSW error|(% style="width:54px" %)PSE|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 16. Off = 0, On = 1.
85 -|(% style="width:200px" %)Precharge error|(% style="width:365px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Precharge error|(% style="width:54px" %)PE|(% style="width:266px" %) |(% style="width:294px" %)
85 +|(% style="width:200px" %)Precharge error|(% style="width:365px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Precharge error|(% style="width:54px" %)PE|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 30. Off = 0, On = 1.
86 86  |(% style="width:200px" %)Short circuit|(% style="width:365px" %)Flowing high battery currents during a long time|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Short circuit|(% style="width:54px" %)SHC|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 19. Off = 0, On = 1.
87 87  |(% style="width:200px" %)Stuck contactor|(% style="width:365px" %)Some contactor got stuck|(% style="width:63px" %)Yes|(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Stuck contactor|(% style="width:54px" %)STC|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 21. Off = 0, On = 1.
88 88  |(% style="width:200px" %)Voltage unbalance (CH)|(% style="width:365px" %)Some of battery modules are unbalanced in voltage (for charging)|(% style="width:63px" %) |(% style="width:66px" %)Yes|(% style="width:70px" %)Yes|(% style="width:121px" %)Voltage unb. CH|(% style="width:54px" %)VUC|(% style="width:266px" %) |(% style="width:294px" %)0x1022-0x1023, bit 3. Off = 0, On = 1.