Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -30,33 +30,28 @@ 30 30 (% style="width:1277px" %) 31 31 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="2" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 140px;" %)BMS Display|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 32 32 |=(% style="width: 94px;" %)**Main X**|=(% style="width: 84px;" %)**Main 3X**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation 33 -|Charging current present|Signal showing the presence of the charging current|Yes|Yes|(% style="width:140px" %)CH curr. present|CCP|(% style="width:140px" %) |(% style="width:142px" %) 33 +|Charging current present|Signal showing the presence of the charging current|Yes*|Yes*|(% style="width:140px" %)CH curr. present|CCP|(% style="width:140px" %) |(% style="width:142px" %) 34 34 |Charging|Command to control the charging contactor|Yes|Yes|(% style="width:140px" %)Charging|CH|(% style="width:140px" %) |(% style="width:142px" %) 35 35 |Charging/Discharging|Command to control the charging/discharging contactor|Yes|Yes|(% style="width:140px" %)Charg./Discharg.|C/D|(% style="width:140px" %) |(% style="width:142px" %) 36 36 |Coolant pump|Command to control the coolant pump|Yes|Yes|(% style="width:140px" %)Coolant pump|CP|(% style="width:140px" %) |(% style="width:142px" %) 37 37 |Cooler|Command to control the cooler|Yes|Yes|(% style="width:140px" %)Cooler|COO|(% style="width:140px" %) |(% style="width:142px" %) 38 -|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes|(% style="width:140px" %)DCH cur. present|DCP|(% style="width:140px" %) |(% style="width:142px" %) 38 +|Discharging current present|Signal showing the presence of the discharging current|Yes*|Yes*|(% style="width:140px" %)DCH cur. present|DCP|(% style="width:140px" %) |(% style="width:142px" %) 39 39 |Discharging|Command to control the discharging contactor|Yes|Yes|(% style="width:140px" %)Discharging|DCH|(% style="width:140px" %) |(% style="width:142px" %) 40 -|Fuse 1 (modules)|ORed internal signals "Fuse 1" from all battery modules|Yes|Yes|(% style="width:140px" %)Fuse 1 (mod.)|F1M|(% style="width:140px" %) |(% style="width:142px" %) 41 -|Fuse 2 (modules)|ORed internal signals "Fuse 2" from all battery modules|Yes|Yes|(% style="width:140px" %)Fuse 2 (mod.)|F2M|(% style="width:140px" %) |(% style="width:142px" %) 42 -|Fuse 3 (modules)|ORed internal signals "Fuse 3" from all battery modules|Yes|Yes|(% style="width:140px" %)Fuse 3 (mod.)|F3M|(% style="width:140px" %) |(% style="width:142px" %) 40 +|Fuse 1 (modules)|ORed internal signals "Fuse 1" from all battery modules|Yes*|Yes*|(% style="width:140px" %)Fuse 1 (mod.)|F1M|(% style="width:140px" %) |(% style="width:142px" %) 41 +|Fuse 2 (modules)|ORed internal signals "Fuse 2" from all battery modules|Yes*|Yes*|(% style="width:140px" %)Fuse 2 (mod.)|F2M|(% style="width:140px" %) |(% style="width:142px" %) 42 +|Fuse 3 (modules)|ORed internal signals "Fuse 3" from all battery modules|Yes*|Yes*|(% style="width:140px" %)Fuse 3 (mod.)|F3M|(% style="width:140px" %) |(% style="width:142px" %) 43 43 |General error (modules)|ORed internal signals "General error" from all battery modules|Yes|Yes|(% style="width:140px" %)Gen.error (mod.)|GEM|(% style="width:140px" %) |(% style="width:142px" %) 44 44 |Heater|Command to control the heater|Yes|Yes|(% style="width:140px" %)Heater|HEA|(% style="width:140px" %) |(% style="width:142px" %) 45 -|Init|Signal showing that the device is in the initialization phase|Yes|Yes|(% style="width:140px" %)Init|INI|(% style="width:140px" %) |(% style="width:142px" %) 46 -|Interlock (modules)|ORed internal signals "Interlock" from all battery modules|Yes|Yes|(% style="width:140px" %)Interlock (mod.)|INM|(% style="width:140px" %) |(% style="width:142px" %) 45 +|Init|Signal showing that the device is in the initialization phase|Yes*|Yes*|(% style="width:140px" %)Init|INI|(% style="width:140px" %) |(% style="width:142px" %) 46 +|Interlock (modules)|ORed internal signals "Interlock" from all battery modules|Yes*|Yes*|(% style="width:140px" %)Interlock (mod.)|INM|(% style="width:140px" %) |(% style="width:142px" %) 47 47 |Main contactor|Command to control the main contactor|Yes|Yes|(% style="width:140px" %)Main contactor|MCO|(% style="width:140px" %) |(% style="width:142px" %) 48 48 |Precharging|Command to control the precharging contactor|Yes|Yes|(% style="width:140px" %)Precharging|PCH|(% style="width:140px" %) |(% style="width:142px" %) 49 -|Service reset|Command to restart the device|Yes|Yes|(% style="width:140px" %)Service reset|SR|(% style="width:140px" %) |(% style="width:142px" %) 49 +|Service reset|Command to restart the device|Yes*|Yes*|(% style="width:140px" %)Service reset|SR|(% style="width:140px" %) |(% style="width:142px" %) 50 50 51 51 (% class="wikigeneratedid" %) 52 - ~*Assignable to discrete outputsandrelays52 +* Cannot be assigned to discrete outputs or relays. 53 53 54 -(% class="wikigeneratedid" %) 55 -~** Assignable to discrete input only 56 56 57 -(% class="wikigeneratedid" %) 58 -~*~*~* Cannot be assigned to discrete output or relay. 59 - 60 60 == Errors == 61 61 62 62 (% style="width:1279px" %) ... ... @@ -66,14 +66,14 @@ 66 66 |Battery cover error|Battery cover is open|(% style="width:87px" %)Yes|(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Battery cover|BCE|(% style="width:142px" %) |(% style="width:134px" %) 67 67 |CH contactor feedback error|The control signal for the charging contactor and the contactor feedback differ|(% style="width:87px" %)Yes|(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)CH cont. feed.|CCF|(% style="width:142px" %) |(% style="width:134px" %) 68 68 |CH/DCH contactor feedback error|The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:87px" %)Yes|(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)C/D cont. feed.|CDF|(% style="width:142px" %) |(% style="width:134px" %) 69 -|Charging current unbalance| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %) | |(% style="width:142px" %) |(% style="width:134px" %) 64 +|Charging current unbalance| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)CH current unb.| |(% style="width:142px" %) |(% style="width:134px" %) 70 70 |Critical error|Critical system error, the BMS is damaged|(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Critical error|CER|(% style="width:142px" %) |(% style="width:134px" %) 71 71 |Current limit error|Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Cur. limit error|CLE|(% style="width:142px" %) |(% style="width:134px" %) 72 72 |Current sensor error|Error in the current sensor circuit|(% style="width:87px" %)Yes|(% style="width:76px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)Current sensor|CSE|(% style="width:142px" %) |(% style="width:134px" %) 73 -|Current unbalance (CH)| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %) ||(% style="width:142px" %) |(% style="width:134px" %)74 -|Current unbalance (DCH)| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %) ||(% style="width:142px" %) |(% style="width:134px" %)68 +|Current unbalance (CH)| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Current unb. CH|CUC|(% style="width:142px" %) |(% style="width:134px" %) 69 +|Current unbalance (DCH)| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Current unb. DCH|CUD|(% style="width:142px" %) |(% style="width:134px" %) 75 75 |DCH contactor feedback error|The control signal for the discharging contactor and the contactor feedback differ|(% style="width:87px" %)Yes|(% style="width:76px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)DCH cont. feed.|DCF|(% style="width:142px" %) |(% style="width:134px" %) 76 -|Discharging current unbalance| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %) | |(% style="width:142px" %) |(% style="width:134px" %) 71 +|Discharging current unbalance| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)DCH current unb.| |(% style="width:142px" %) |(% style="width:134px" %) 77 77 |FS error|SD card read/write error|(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)FS error|FSE|(% style="width:142px" %) |(% style="width:134px" %) 78 78 |High contactor temperature|Temperature of a contactor is too high|(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Hi. cont. temp.|HCT|(% style="width:142px" %) |(% style="width:134px" %) 79 79 |High humidity|Increased humidity inside the battery|(% style="width:87px" %) |(% style="width:76px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)High humidity|HHU|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -80,7 +80,7 @@ 80 80 |High voltage fault|Failure of high voltage measuring circuits|(% style="width:87px" %)Yes|(% style="width:76px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)HV fault|HVF|(% style="width:142px" %) |(% style="width:134px" %) 81 81 |HVIL error|Breakage of high-voltage interlock current loop|(% style="width:87px" %)Yes|(% style="width:76px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)HVIL error|HE|(% style="width:142px" %) |(% style="width:134px" %) 82 82 |Insulation fault|Insulation resistance is too low|(% style="width:87px" %)Yes|(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Insulation fault|INF|(% style="width:142px" %) |(% style="width:134px" %) 83 -|Module offline|Some of battery modules is offline|(% style="width:87px" %)Yes|(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %) Logicoffline|LOF|(% style="width:142px" %) |(% style="width:134px" %)78 +|Module offline|Some of battery modules is offline|(% style="width:87px" %)Yes|(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Module offline|MOF|(% style="width:142px" %) |(% style="width:134px" %) 84 84 |Main contactor feedback error|The control signal for the main contactor and the contactor feedback differ|(% style="width:87px" %)Yes|(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Main cont. feed.|MCF|(% style="width:142px" %) |(% style="width:134px" %) 85 85 |Mount error|SD card cannot be mounted|(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Mount error|MNT|(% style="width:142px" %) |(% style="width:134px" %) 86 86 |Need acknowledge|There is an unacknowledged error in error journal|(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Need ACK|ACK|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -91,8 +91,8 @@ 91 91 |Precharge error|Capacitive load pre-charge process did not end during the estimated time|(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Precharge error|PE|(% style="width:142px" %) |(% style="width:134px" %) 92 92 |Short circuit|Flowing high battery currents during a long time|(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Short circuit|SHC|(% style="width:142px" %) |(% style="width:134px" %) 93 93 |Stuck contactor|Some contactor got stuck|(% style="width:87px" %)Yes|(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Stuck contactor|STC|(% style="width:142px" %) |(% style="width:134px" %) 94 -|Voltage unbalance (CH)| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %) ||(% style="width:142px" %) |(% style="width:134px" %)95 -|Voltage unbalance (DCH)| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %) ||(% style="width:142px" %) |(% style="width:134px" %)89 +|Voltage unbalance (CH)| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Voltage unb. CH|VUC|(% style="width:142px" %) |(% style="width:134px" %) 90 +|Voltage unbalance (DCH)| |(% style="width:87px" %) |(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)Voltage unb. DCH|VUD|(% style="width:142px" %) |(% style="width:134px" %) 96 96 |Water|There is water in the battery enclosure|(% style="width:87px" %)Yes|(% style="width:76px" %) |(% style="width:81px" %)Yes|(% style="width:142px" %)Water|WHU|(% style="width:142px" %) |(% style="width:134px" %) 97 97 |WDT reset|Watchdog timer reset the device|(% style="width:87px" %)Yes|(% style="width:76px" %)Yes|(% style="width:81px" %)Yes|(% style="width:142px" %)WDT reset|WDT|(% style="width:142px" %) |(% style="width:134px" %) 98 98