... ... @@ -60,51 +60,40 @@
60 60  == Errors ==
61 61  
62 62  (% style="width:1279px" %)
63 -|(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="2" rowspan="1" style="width:142px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus**
64 -|=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation
65 -|ADC error|Error of the ADC that measures the battery current|•|Yes|Yes|Yes|(% style="width:142px" %)ADC error|ADC|(% style="width:142px" %) |(% style="width:134px" %)
66 -|Battery cover error|Battery cover is open|•|Yes|Yes|Yes|(% style="width:142px" %)Battery cover|BCE|(% style="width:142px" %) |(% style="width:134px" %)
67 -|CH contactor feedback error|The control signal for the charging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %)CH cont. feed.|CCF|(% style="width:142px" %) |(% style="width:134px" %)
68 -|CH/DCH contactor feedback error|The control signal for the charging/discharging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %)C/D cont. feed.|CDF|(% style="width:142px" %) |(% style="width:134px" %)
69 -|Critical error|Critical system error, the BMS is damaged| |Yes|Yes|Yes|(% style="width:142px" %)Critical error|CER|(% style="width:142px" %) |(% style="width:134px" %)
70 -|Current limit error|Charging or discharging current is more than the limit calculated by Charge map or Discharge map| |Yes| |Yes|(% style="width:142px" %)Cur. limit error|CLE|(% style="width:142px" %) |(% style="width:134px" %)
71 -|Current sensor error|Error in the current sensor circuit|•|Yes|Yes|Yes|(% style="width:142px" %)Current sensor|CSE|(% style="width:142px" %) |(% style="width:134px" %)
72 -|DCH contactor feedback error|The control signal for the discharging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %)DCH cont. feed.|DCF|(% style="width:142px" %) |(% style="width:134px" %)
73 -|FS error|SD card read/write error| |Yes|Yes|Yes|(% style="width:142px" %)FS error|FSE|(% style="width:142px" %) |(% style="width:134px" %)
74 -|High contactor temperature|Temperature of a contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %)Hi. cont. temp.|HCT|(% style="width:142px" %) |(% style="width:134px" %)
75 -|High humidity|Increased humidity inside the battery| | |Yes|Yes|(% style="width:142px" %)High humidity|HHU|(% style="width:142px" %) |(% style="width:134px" %)
76 -|High Logic temperature|At least one of the Logic devices is overheated| | |Yes|Yes|(% style="width:142px" %)Hi. Logic temp.|HLT|(% style="width:142px" %) |(% style="width:134px" %)
77 -|High temperature (CH)|Temperature is too high for charging| |Yes|Yes|Yes|(% style="width:142px" %)High temp. CH|HTC|(% style="width:142px" %) |(% style="width:134px" %)
78 -|High temperature (DCH)|Temperature is too high for discharging| |Yes|Yes|Yes|(% style="width:142px" %)High temp. DCH|HTD|(% style="width:142px" %) |(% style="width:134px" %)
79 -|High voltage fault|Failure of high voltage measuring circuits|•| | |Yes|(% style="width:142px" %)HV fault|HVF|(% style="width:142px" %) |(% style="width:134px" %)
80 -|HVIL error|Breakage of high-voltage interlock current loop|•| | |Yes|(% style="width:142px" %)HVIL error|HE|(% style="width:142px" %) |(% style="width:134px" %)
81 -|HYG offline|Connection with the HYG forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %)HYG offline|HYG|(% style="width:142px" %) |(% style="width:134px" %)
82 -|Insulation fault|Insulation resistance is too low|•|Yes|Yes|Yes|(% style="width:142px" %)Insulation fault|INF|(% style="width:142px" %) |(% style="width:134px" %)
83 -|Logic count error|The number of BMS Logic devices differs from the required value| | |Yes|Yes|(% style="width:142px" %)Logic count|LOG|(% style="width:142px" %) |(% style="width:134px" %)
84 -|Logic offline (Cell monitor offline)|BMS Main devices: at least one of the Logic devices is offline.
85 -BMS Mini devices: connection with cell monitor is lost.|•|Yes|Yes|Yes|(% style="width:142px" %)Logic offline|LOF|(% style="width:142px" %) |(% style="width:134px" %)
86 -|Low temperature (CH)|Temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %)Low temp. CH|LTC|(% style="width:142px" %) |(% style="width:134px" %)
87 -|Low temperature (DCH)|Temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %)Low temp. DCH|LTD|(% style="width:142px" %) |(% style="width:134px" %)
88 -|Main contactor feedback error|The control signal for the main contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %)Main cont. feed.|MCF|(% style="width:142px" %) |(% style="width:134px" %)
89 -|Mount error|SD card cannot be mounted| |Yes|Yes|Yes|(% style="width:142px" %)Mount error|MNT|(% style="width:142px" %) |(% style="width:134px" %)
90 -|Need acknowledge|There is an unacknowledged error in error journal| |Yes|Yes|Yes|(% style="width:142px" %)Need ACK|ACK|(% style="width:142px" %) |(% style="width:134px" %)
91 -|No temperature sensors|The device has no temperature sensors connected|•|Yes|Yes|Yes|(% style="width:142px" %)No temp. sens.|NTS|(% style="width:142px" %) |(% style="width:134px" %)
92 -|Overcurrent|The battery current is too high| |Yes|Yes|Yes|(% style="width:142px" %)Overcurrent|OC|(% style="width:142px" %) |(% style="width:134px" %)
93 -|Overvoltage|Voltage of any cell is too high| |Yes|Yes|Yes|(% style="width:142px" %)Overvoltage|OV|(% style="width:142px" %) |(% style="width:134px" %)
94 -|PCH contactor feedback error|The control signal for the precharging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %)PCH cont. feed.|PCF|(% style="width:142px" %) |(% style="width:134px" %)
95 -|Power fault|External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|•| | |Yes|(% style="width:142px" %)Power fault|PF|(% style="width:142px" %) |(% style="width:134px" %)
96 -|Power switch error|Short circuit in contactor coil control circuit or power switch overheating|•| | |Yes|(% style="width:142px" %)PSW error|PSE|(% style="width:142px" %) |(% style="width:134px" %)
97 -|Precharge error|Capacitive load pre-charge process did not end during the estimated time| |Yes|Yes|Yes|(% style="width:142px" %)Precharge error|PE|(% style="width:142px" %) |(% style="width:134px" %)
98 -|Settings error|Wrong checksum of the device settings| | |Yes| |(% style="width:142px" %)Settings err.|SET|(% style="width:142px" %) |(% style="width:134px" %)
99 -|Short circuit|Flowing high battery currents during a long time| |Yes|Yes|Yes|(% style="width:142px" %)Short circuit|SHC|(% style="width:142px" %) |(% style="width:134px" %)
100 -|Shunt error|Internal error of the shunt current sensor|•|Yes|Yes|Yes|(% style="width:142px" %)Shunt error|SHE|(% style="width:142px" %) |(% style="width:134px" %)
101 -|Shunt offline|Connection with the shunt current sensor is lost|•|Yes|Yes|Yes|(% style="width:142px" %)Shunt offline|SHO|(% style="width:142px" %) |(% style="width:134px" %)
102 -|Spirit offline|Connection with the Spirit forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %)Spirit offline|SPI|(% style="width:142px" %) |(% style="width:134px" %)
103 -|Stuck contactor|Some contactor got stuck|•|Yes|Yes|Yes|(% style="width:142px" %)Stuck contactor|STC|(% style="width:142px" %) |(% style="width:134px" %)
104 -|Temperature sensor is shorted|Some temperature sensors are shorted|•|Yes|Yes|Yes|(% style="width:142px" %)Shorted temp.|TSS|(% style="width:142px" %) |(% style="width:134px" %)
105 -|Unallowable charging|Charging the battery through the discharging contactor| |Yes|Yes|Yes|(% style="width:142px" %)Unallowable CH|UCH|(% style="width:142px" %) |(% style="width:134px" %)
106 -|Undervoltage|Voltage of any cell is too low| |Yes|Yes|Yes|(% style="width:142px" %)Undervoltage|UV|(% style="width:142px" %) |(% style="width:134px" %)
107 -|Water|There is water in the battery enclosure|•| |Yes|Yes|(% style="width:142px" %)Water|WHU|(% style="width:142px" %) |(% style="width:134px" %)
108 -|WDT reset|Watchdog timer reset the device|•|Yes|Yes|Yes|(% style="width:142px" %)WDT reset|WDT|(% style="width:142px" %) |(% style="width:134px" %)
63 +|(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="2" rowspan="1" style="width:248px" %)**Compability**|(% colspan="2" rowspan="1" style="width:142px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus**
64 +|=(% style="width: 93px;" %)**Main X**|=(% style="width: 80px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation
65 +|ADC error|Error of the ADC that measures the battery current|•|Yes|Yes|(% style="width:142px" %)ADC error|ADC|(% style="width:142px" %) |(% style="width:134px" %)
66 +|Battery cover error|Battery cover is open|•|Yes|Yes|(% style="width:142px" %)Battery cover|BCE|(% style="width:142px" %) |(% style="width:134px" %)
67 +|CH contactor feedback error|The control signal for the charging contactor and the contactor feedback differ|•| |Yes|(% style="width:142px" %)CH cont. feed.|CCF|(% style="width:142px" %) |(% style="width:134px" %)
68 +|CH/DCH contactor feedback error|The control signal for the charging/discharging contactor and the contactor feedback differ|•| |Yes|(% style="width:142px" %)C/D cont. feed.|CDF|(% style="width:142px" %) |(% style="width:134px" %)
69 +|Charging current unbalance| | | | |(% style="width:142px" %) | |(% style="width:142px" %) |(% style="width:134px" %)
70 +|Critical error|Critical system error, the BMS is damaged| |Yes|Yes|(% style="width:142px" %)Critical error|CER|(% style="width:142px" %) |(% style="width:134px" %)
71 +|Current limit error|Charging or discharging current is more than the limit calculated by Charge map or Discharge map| |Yes|Yes|(% style="width:142px" %)Cur. limit error|CLE|(% style="width:142px" %) |(% style="width:134px" %)
72 +|Current sensor error|Error in the current sensor circuit|•|Yes|Yes|(% style="width:142px" %)Current sensor|CSE|(% style="width:142px" %) |(% style="width:134px" %)
73 +|Current unbalance (CH)| | | | |(% style="width:142px" %) | |(% style="width:142px" %) |(% style="width:134px" %)
74 +|Current unbalance (DCH)| | | | |(% style="width:142px" %) | |(% style="width:142px" %) |(% style="width:134px" %)
75 +|DCH contactor feedback error|The control signal for the discharging contactor and the contactor feedback differ|•| |Yes|(% style="width:142px" %)DCH cont. feed.|DCF|(% style="width:142px" %) |(% style="width:134px" %)
76 +|Discharging current unbalance| | | | |(% style="width:142px" %) | |(% style="width:142px" %) |(% style="width:134px" %)
77 +|FS error|SD card read/write error| |Yes|Yes|(% style="width:142px" %)FS error|FSE|(% style="width:142px" %) |(% style="width:134px" %)
78 +|High contactor temperature|Temperature of a contactor is too high| |Yes|Yes|(% style="width:142px" %)Hi. cont. temp.|HCT|(% style="width:142px" %) |(% style="width:134px" %)
79 +|High humidity|Increased humidity inside the battery| | |Yes|(% style="width:142px" %)High humidity|HHU|(% style="width:142px" %) |(% style="width:134px" %)
80 +|High voltage fault|Failure of high voltage measuring circuits|•| |Yes|(% style="width:142px" %)HV fault|HVF|(% style="width:142px" %) |(% style="width:134px" %)
81 +|HVIL error|Breakage of high-voltage interlock current loop|•| |Yes|(% style="width:142px" %)HVIL error|HE|(% style="width:142px" %) |(% style="width:134px" %)
82 +|Insulation fault|Insulation resistance is too low|•|Yes|Yes|(% style="width:142px" %)Insulation fault|INF|(% style="width:142px" %) |(% style="width:134px" %)
83 +|Module offline|Some of battery modules is offline|•|Yes|Yes|(% style="width:142px" %)Logic offline|LOF|(% style="width:142px" %) |(% style="width:134px" %)
84 +|Main contactor feedback error|The control signal for the main contactor and the contactor feedback differ|•| |Yes|(% style="width:142px" %)Main cont. feed.|MCF|(% style="width:142px" %) |(% style="width:134px" %)
85 +|Mount error|SD card cannot be mounted| |Yes|Yes|(% style="width:142px" %)Mount error|MNT|(% style="width:142px" %) |(% style="width:134px" %)
86 +|Need acknowledge|There is an unacknowledged error in error journal| |Yes|Yes|(% style="width:142px" %)Need ACK|ACK|(% style="width:142px" %) |(% style="width:134px" %)
87 +|Overcurrent|The battery current is too high| |Yes|Yes|(% style="width:142px" %)Overcurrent|OC|(% style="width:142px" %) |(% style="width:134px" %)
88 +|PCH contactor feedback error|The control signal for the precharging contactor and the contactor feedback differ|•| |Yes|(% style="width:142px" %)PCH cont. feed.|PCF|(% style="width:142px" %) |(% style="width:134px" %)
89 +|Power fault|External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|•| |Yes|(% style="width:142px" %)Power fault|PF|(% style="width:142px" %) |(% style="width:134px" %)
90 +|Power switch error|Short circuit in contactor coil control circuit or power switch overheating|•| |Yes|(% style="width:142px" %)PSW error|PSE|(% style="width:142px" %) |(% style="width:134px" %)
91 +|Precharge error|Capacitive load pre-charge process did not end during the estimated time| |Yes|Yes|(% style="width:142px" %)Precharge error|PE|(% style="width:142px" %) |(% style="width:134px" %)
92 +|Short circuit|Flowing high battery currents during a long time| |Yes|Yes|(% style="width:142px" %)Short circuit|SHC|(% style="width:142px" %) |(% style="width:134px" %)
93 +|Stuck contactor|Some contactor got stuck|•|Yes|Yes|(% style="width:142px" %)Stuck contactor|STC|(% style="width:142px" %) |(% style="width:134px" %)
94 +|Voltage unbalance (CH)| | | | |(% style="width:142px" %) | |(% style="width:142px" %) |(% style="width:134px" %)
95 +|Voltage unbalance (DCH)| | | | |(% style="width:142px" %) | |(% style="width:142px" %) |(% style="width:134px" %)
96 +|Water|There is water in the battery enclosure|•| |Yes|(% style="width:142px" %)Water|WHU|(% style="width:142px" %) |(% style="width:134px" %)
97 +|WDT reset|Watchdog timer reset the device|•|Yes|Yes|(% style="width:142px" %)WDT reset|WDT|(% style="width:142px" %) |(% style="width:134px" %)
109 109  
110 110  ~* The signal can be assigned to discrete outputs and relays.