Last modified by Admin on 2025/02/21 14:51

From version 26.2
edited by Admin
on 2025/02/04 08:04
Change comment: There is no comment for this version
To version 25.10
edited by Admin
on 2025/02/04 07:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -33,17 +33,17 @@
33 33  |Charging current present|Signal showing the presence of the charging current|Yes|Yes|(% style="width:140px" %)CH curr. present|CCP|(% style="width:140px" %) |(% style="width:142px" %)
34 34  |Charging|Command to control the charging contactor|Yes|Yes|(% style="width:140px" %)Charging|CH|(% style="width:140px" %) |(% style="width:142px" %)
35 35  |Charging/Discharging|Command to control the charging/discharging contactor|Yes|Yes|(% style="width:140px" %)Charg./Discharg.|C/D|(% style="width:140px" %) |(% style="width:142px" %)
36 -|Coolant pump|Command to control the coolant pump|Yes|Yes|(% style="width:140px" %)Coolant pump|CP|(% style="width:140px" %) |(% style="width:142px" %)
36 +|Coolant pump|Command to control the coolant pump| |Yes|(% style="width:140px" %)Coolant pump| |(% style="width:140px" %) |(% style="width:142px" %)
37 37  |Cooler|Command to control the cooler|Yes|Yes|(% style="width:140px" %)Cooler|COO|(% style="width:140px" %) |(% style="width:142px" %)
38 38  |Discharging current present|Signal showing the presence of the discharging current|Yes|Yes|(% style="width:140px" %)DCH cur. present|DCP|(% style="width:140px" %) |(% style="width:142px" %)
39 39  |Discharging|Command to control the discharging contactor|Yes|Yes|(% style="width:140px" %)Discharging|DCH|(% style="width:140px" %) |(% style="width:142px" %)
40 -|Fuse 1 (modules)|ORed internal signals "Fuse 1" from all battery modules|Yes|Yes|(% style="width:140px" %)Fuse 1 (mod.)|F1M|(% style="width:140px" %) |(% style="width:142px" %)
41 -|Fuse 2 (modules)|ORed internal signals "Fuse 2" from all battery modules|Yes|Yes|(% style="width:140px" %)Fuse 2 (mod.)|F2M|(% style="width:140px" %) |(% style="width:142px" %)
42 -|Fuse 3 (modules)|ORed internal signals "Fuse 3" from all battery modules|Yes|Yes|(% style="width:140px" %)Fuse 3 (mod.)|F3M|(% style="width:140px" %) |(% style="width:142px" %)
43 -|General error (modules)|ORed internal signals "General error" from all battery modules|Yes|Yes|(% style="width:140px" %)Gen.error (mod.)|GEM|(% style="width:140px" %) |(% style="width:142px" %)
40 +|Fuse 1 (modules)|ORed internal signals "Fuse 1" from all battery modules|Yes|Yes|(% style="width:140px" %) | |(% style="width:140px" %) |(% style="width:142px" %)
41 +|Fuse 2 (modules)|ORed internal signals "Fuse 2" from all battery modules|Yes|Yes|(% style="width:140px" %) | |(% style="width:140px" %) |(% style="width:142px" %)
42 +|Fuse 3 (modules)|ORed internal signals "Fuse 3" from all battery modules|Yes|Yes|(% style="width:140px" %) | |(% style="width:140px" %) |(% style="width:142px" %)
43 +|General error (modules)|ORed internal signals "General error" from all battery modules|Yes|Yes|(% style="width:140px" %) | |(% style="width:140px" %) |(% style="width:142px" %)
44 44  |Heater|Command to control the heater|Yes|Yes|(% style="width:140px" %)Heater|HEA|(% style="width:140px" %) |(% style="width:142px" %)
45 45  |Init|Signal showing that the device is in the initialization phase|Yes|Yes|(% style="width:140px" %)Init|INI|(% style="width:140px" %) |(% style="width:142px" %)
46 -|Interlock (modules)|ORed internal signals "Interlock" from all battery modules|Yes|Yes|(% style="width:140px" %)Interlock (mod.)|INM|(% style="width:140px" %) |(% style="width:142px" %)
46 +|Interlock (modules)|ORed internal signals "Interlock" from all battery modules|Yes|Yes|(% style="width:140px" %) | |(% style="width:140px" %) |(% style="width:142px" %)
47 47  |Main contactor|Command to control the main contactor|Yes|Yes|(% style="width:140px" %)Main contactor|MCO|(% style="width:140px" %) |(% style="width:142px" %)
48 48  |Precharging|Command to control the precharging contactor|Yes|Yes|(% style="width:140px" %)Precharging|PCH|(% style="width:140px" %) |(% style="width:142px" %)
49 49  |Service reset|Command to restart the device|Yes|Yes|(% style="width:140px" %)Service reset|SR|(% style="width:140px" %) |(% style="width:142px" %)
... ... @@ -64,13 +64,20 @@
64 64  |=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation
65 65  |ADC error|Error of the ADC that measures the battery current|•|Yes|Yes|Yes|(% style="width:142px" %)ADC error|ADC|(% style="width:142px" %) |(% style="width:134px" %)
66 66  |Battery cover error|Battery cover is open|•|Yes|Yes|Yes|(% style="width:142px" %)Battery cover|BCE|(% style="width:142px" %) |(% style="width:134px" %)
67 +|Cell count error|Number of cells does not match the specified value|•|Yes|Yes|Yes|(% style="width:142px" %)Cell count|CEL|(% style="width:142px" %) |(% style="width:134px" %)
68 +|CH contactor cycles error|Switching frequency of the charging contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %)CH cont. cycle|CCC|(% style="width:142px" %) |(% style="width:134px" %)
67 67  |CH contactor feedback error|The control signal for the charging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %)CH cont. feed.|CCF|(% style="width:142px" %) |(% style="width:134px" %)
68 68  |CH/DCH contactor feedback error|The control signal for the charging/discharging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %)C/D cont. feed.|CDF|(% style="width:142px" %) |(% style="width:134px" %)
71 +|Combilift offline|Connection with the Combilift forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %)Combilift offl.|COM|(% style="width:142px" %) |(% style="width:134px" %)
72 +|Contactor feedback error|Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device| |Yes| | |(% style="width:142px" %)Cont. feed. er.|CFE|(% style="width:142px" %) |(% style="width:134px" %)
69 69  |Critical error|Critical system error, the BMS is damaged| |Yes|Yes|Yes|(% style="width:142px" %)Critical error|CER|(% style="width:142px" %) |(% style="width:134px" %)
74 +|Crown error|Connection with the Crown forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %)Crown error|CRO|(% style="width:142px" %) |(% style="width:134px" %)
70 70  |Current limit error|Charging or discharging current is more than the limit calculated by Charge map or Discharge map| |Yes| |Yes|(% style="width:142px" %)Cur. limit error|CLE|(% style="width:142px" %) |(% style="width:134px" %)
71 71  |Current sensor error|Error in the current sensor circuit|•|Yes|Yes|Yes|(% style="width:142px" %)Current sensor|CSE|(% style="width:142px" %) |(% style="width:134px" %)
77 +|DCH contactor cycles error|Switching frequency of the discharging contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %)DCH cont. cycle|DCC|(% style="width:142px" %) |(% style="width:134px" %)
72 72  |DCH contactor feedback error|The control signal for the discharging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %)DCH cont. feed.|DCF|(% style="width:142px" %) |(% style="width:134px" %)
73 73  |FS error|SD card read/write error| |Yes|Yes|Yes|(% style="width:142px" %)FS error|FSE|(% style="width:142px" %) |(% style="width:134px" %)
80 +|General error|Special configurable error depending on other errors| |Yes*|Yes*|Yes*|(% style="width:142px" %)General error|GE|(% style="width:142px" %) |(% style="width:134px" %)
74 74  |High contactor temperature|Temperature of a contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %)Hi. cont. temp.|HCT|(% style="width:142px" %) |(% style="width:134px" %)
75 75  |High humidity|Increased humidity inside the battery| | |Yes|Yes|(% style="width:142px" %)High humidity|HHU|(% style="width:142px" %) |(% style="width:134px" %)
76 76  |High Logic temperature|At least one of the Logic devices is overheated| | |Yes|Yes|(% style="width:142px" %)Hi. Logic temp.|HLT|(% style="width:142px" %) |(% style="width:134px" %)