Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -34,26 +34,13 @@ 34 34 |Charging|Command to control the charging contactor|Yes|Yes*|Yes|(% style="width:140px" %)Charging|CH|(% style="width:140px" %) |(% style="width:142px" %) 35 35 |Charging/Discharging|Command to control the charging/discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %)Charg./Discharg.|C/D|(% style="width:140px" %) |(% style="width:142px" %) 36 36 |Cooler|Command to control the cooler|Yes|Yes|Yes|(% style="width:140px" %)Cooler|COO|(% style="width:140px" %) |(% style="width:142px" %) 37 -|Crown EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Crown EWS|EWS|(% style="width:140px" %) |(% style="width:142px" %) 38 -|Discharging (AUX)|Command to control the auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Disch. AUX|AUX|(% style="width:140px" %) |(% style="width:142px" %) 39 -|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %)DCH curr. pres.|DCP|(% style="width:140px" %) |(% style="width:142px" %) 37 +|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %)DCH cur. present|DCP|(% style="width:140px" %) |(% style="width:142px" %) 40 40 |Discharging|Command to control the discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %)Discharging|DCH|(% style="width:140px" %) |(% style="width:142px" %) 41 -|External 1|Command to control an external scheme|Yes|Yes|Yes|(% style="width:140px" %)External 1|EX1|(% style="width:140px" %) |(% style="width:142px" %) 42 -|Heater (AUX)|Command to control the auxiliary heater| |Yes| |(% style="width:140px" %)Heater (AUX)|HAU|(% style="width:140px" %) |(% style="width:142px" %) 43 43 |Heater|Command to control the heater|Yes|Yes|Yes|(% style="width:140px" %)Heater|HEA|(% style="width:140px" %) |(% style="width:142px" %) 44 -|High charging current|Signal indicating that the charging current is high|Yes|Yes~*~*|Yes|(% style="width:140px" %)High ch. curr.|HCC|(% style="width:140px" %) |(% style="width:142px" %) 45 45 |Init|Signal showing that the device is in the initialization phase|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Init|INI|(% style="width:140px" %) |(% style="width:142px" %) 46 -|Low SOC|Signal indicatiing that the battery has low SOC|Yes|Yes|Yes|(% style="width:140px" %)Low SOC|LOS|(% style="width:140px" %) |(% style="width:142px" %) 47 47 |Main contactor|Command to control the main contactor|Yes|Yes*|Yes|(% style="width:140px" %)Main contactor|MCO|(% style="width:140px" %) |(% style="width:142px" %) 48 -|Power down ACK|Command that acknowledges the BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on the power down request|Yes|Yes~*~*|Yes|(% style="width:140px" %)Power down ACK|PDA|(% style="width:140px" %) |(% style="width:142px" %) 49 -|Power up|Signal indicating the BMS power status|Yes|Yes|Yes|(% style="width:140px" %)Power up|PUP|(% style="width:140px" %) |(% style="width:142px" %) 50 50 |Precharging|Command to control the precharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Precharging|PCH|(% style="width:140px" %) |(% style="width:142px" %) 51 -|Ready to charge|Signal showing that the battery is ready for charging|Yes|Yes|Yes|(% style="width:140px" %)Ready to charge|RTC|(% style="width:140px" %) |(% style="width:142px" %) 52 -|Ready to discharge|Signal showing that the battery is ready for discharging|Yes|Yes|Yes|(% style="width:140px" %)Ready to disch.|RTD|(% style="width:140px" %) |(% style="width:142px" %) 53 53 |Service reset|Command to restart the device|Yes~*~**| |Yes~*~**|(% style="width:140px" %)Service reset|SR|(% style="width:140px" %) |(% style="width:142px" %) 54 -|Shutdown request (Combilift)|Command to open the dischrging contactor from the Combilift truck|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Combilift shutd.|CSH|(% style="width:140px" %) |(% style="width:142px" %) 55 -|Shutdown request (HYG/Spirit)|Command to open the dischrging contactor from the HYG truck|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)HYG shutdown|HSH|(% style="width:140px" %) |(% style="width:142px" %) 56 -|Voltage too high for charging|Signal indicating that the battery is fully charged|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Volt. too high|VTH|(% style="width:140px" %) |(% style="width:142px" %) 57 57 58 58 (% class="wikigeneratedid" %) 59 59 ~* Assignable to relay only