- Content
-
... ... @@ -99,24 +99,24 @@ 99 99 |DCH contactor cycles error|Switching frequency of the discharging contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %) |DCC|(% style="width:142px" %) |(% style="width:134px" %) 100 100 |DCH contactor feedback error|The control signal for the discharging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %) |DCF|(% style="width:142px" %) |(% style="width:134px" %) 101 101 |FS error|SD card read/write error| |Yes|Yes|Yes|(% style="width:142px" %) |FSE|(% style="width:142px" %) |(% style="width:134px" %) 102 -|General error| | |Yes*|Yes*|Yes*|(% style="width:142px" %) |GE|(% style="width:142px" %) |(% style="width:134px" %) 103 -|High contactor temperature| | |Yes|Yes|Yes|(% style="width:142px" %) |CHT|(% style="width:142px" %) |(% style="width:134px" %) 104 -|High humidity|humidity ofthe batteryis increased;| | |Yes|Yes|(% style="width:142px" %) |HH|(% style="width:142px" %) |(% style="width:134px" %)105 -|High Logic temperature| at least one of the Logic devices is overheated;| | |Yes|Yes|(% style="width:142px" %) |LHT|(% style="width:142px" %) |(% style="width:134px" %)106 -|High temperature (CH)| temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |HCT|(% style="width:142px" %) |(% style="width:134px" %)107 -|High temperature (DCH)| temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |HDT|(% style="width:142px" %) |(% style="width:134px" %)108 -|High voltage fault| failure of high voltage measuring circuits;|•| | |Yes|(% style="width:142px" %) |HVF|(% style="width:142px" %) |(% style="width:134px" %)109 -|HVIL error| breakage of high-voltage interlock current loop;|•| | |Yes|(% style="width:142px" %) |HE|(% style="width:142px" %) |(% style="width:134px" %)110 -|HYG offline| connection withaHYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |HYG|(% style="width:142px" %) |(% style="width:134px" %)102 +|General error|Special configurable error depending on other errors| |Yes*|Yes*|Yes*|(% style="width:142px" %) |GE|(% style="width:142px" %) |(% style="width:134px" %) 103 +|High contactor temperature|Temperature of a contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %) |CHT|(% style="width:142px" %) |(% style="width:134px" %) 104 +|High humidity|Increased humidity inside the battery| | |Yes|Yes|(% style="width:142px" %) |HH|(% style="width:142px" %) |(% style="width:134px" %) 105 +|High Logic temperature|At least one of the Logic devices is overheated| | |Yes|Yes|(% style="width:142px" %) |LHT|(% style="width:142px" %) |(% style="width:134px" %) 106 +|High temperature (CH)|Temperature is too high for charging| |Yes|Yes|Yes|(% style="width:142px" %) |HCT|(% style="width:142px" %) |(% style="width:134px" %) 107 +|High temperature (DCH)|Temperature is too high for discharging| |Yes|Yes|Yes|(% style="width:142px" %) |HDT|(% style="width:142px" %) |(% style="width:134px" %) 108 +|High voltage fault|Failure of high voltage measuring circuits|•| | |Yes|(% style="width:142px" %) |HVF|(% style="width:142px" %) |(% style="width:134px" %) 109 +|HVIL error|Breakage of high-voltage interlock current loop|•| | |Yes|(% style="width:142px" %) |HE|(% style="width:142px" %) |(% style="width:134px" %) 110 +|HYG offline|Connection with the HYG forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |HYG|(% style="width:142px" %) |(% style="width:134px" %) 111 111 |Insulation fault| |•|Yes|Yes|Yes|(% style="width:142px" %) |INF|(% style="width:142px" %) |(% style="width:134px" %) 112 112 |Logic count error| | | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %) 113 113 |Logic offline 114 -Cell monitor offline|BMS Main devices: at least one of the Logic devices is offline ;115 -BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |LOF|(% style="width:142px" %) |(% style="width:134px" %) 116 -|Low temperature (CH)| temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |LCT|(% style="width:142px" %) |(% style="width:134px" %)117 -|Low temperature (DCH)| temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |LDT|(% style="width:142px" %) |(% style="width:134px" %)118 -|Main contactor feedback error| the control signalsfor the main contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |MCF|(% style="width:142px" %) |(% style="width:134px" %)119 -|Mount error| | |Yes|Yes|Yes|(% style="width:142px" %) |MNT|(% style="width:142px" %) |(% style="width:134px" %) 114 +Cell monitor offline|BMS Main devices: at least one of the Logic devices is offline. 115 +BMS Mini devices: connection with cell monitor is lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |LOF|(% style="width:142px" %) |(% style="width:134px" %) 116 +|Low temperature (CH)|Temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |LCT|(% style="width:142px" %) |(% style="width:134px" %) 117 +|Low temperature (DCH)|Temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |LDT|(% style="width:142px" %) |(% style="width:134px" %) 118 +|Main contactor feedback error|The control signal for the main contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %) |MCF|(% style="width:142px" %) |(% style="width:134px" %) 119 +|Mount error|SD card cannot be mounted| |Yes|Yes|Yes|(% style="width:142px" %) |MNT|(% style="width:142px" %) |(% style="width:134px" %) 120 120 |Need acknowledge|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |ACK|(% style="width:142px" %) |(% style="width:134px" %) 121 121 |No temperature sensors|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |NTS|(% style="width:142px" %) |(% style="width:134px" %) 122 122 |Overcurrent| | |Yes|Yes|Yes|(% style="width:142px" %) |OC|(% style="width:142px" %) |(% style="width:134px" %)