Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,16 +46,16 @@ 46 46 |Balancing 2|Command to balance the second series of cells| |Yes*|Yes|(% style="width:140px" %) |BA2|(% style="width:140px" %) |(% style="width:142px" %) 47 47 |Cell analysis|Signal indicating cell analysis process|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CEA|(% style="width:140px" %) |(% style="width:142px" %) 48 48 |Charging current present|Signal showing the presence of the charging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |CCP|(% style="width:140px" %) |(% style="width:142px" %) 49 -|Charging| Commandtocontrol the charging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |CH|(% style="width:140px" %) |(% style="width:142px" %)50 -|Charging/discharging| Commandtocontrolthe charging/discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |C/D|(% style="width:140px" %) |(% style="width:142px" %)51 -|Cooler| Command tocontrolthecooler|Yes|Yes|Yes|(% style="width:140px" %) |COO|(% style="width:140px" %) |(% style="width:142px" %)49 +|Charging|state of the charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |CH|(% style="width:140px" %) |(% style="width:142px" %) 50 +|Charging/discharging|state of the charging/discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |C/D|(% style="width:140px" %) |(% style="width:142px" %) 51 +|Cooler|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |COO|(% style="width:140px" %) |(% style="width:142px" %) 52 52 |Crown EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |EWS|(% style="width:140px" %) |(% style="width:142px" %) 53 -|Discharging (AUX)| Commandtocontrolthe auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %) |AUX|(% style="width:140px" %) |(% style="width:142px" %)54 -|Discharging current present| Signal showingthe presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |DCP|(% style="width:140px" %) |(% style="width:142px" %)55 -|Discharging| Commandtocontrolthe discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |DCH|(% style="width:140px" %) |(% style="width:142px" %)56 -|External 1| Commandtocontrolan externalscheme|Yes|Yes|Yes|(% style="width:140px" %) |EX1|(% style="width:140px" %) |(% style="width:142px" %)57 -|Heater (AUX)| Commandto control the auxiliary heater| |Yes| |(% style="width:140px" %) |HA|(% style="width:140px" %) |(% style="width:142px" %)58 -|Heater| Command toconon a heater;|Yes|Yes|Yes|(% style="width:140px" %) |HEA|(% style="width:140px" %) |(% style="width:142px" %)53 +|Discharging (AUX)|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |AUX|(% style="width:140px" %) |(% style="width:142px" %) 54 +|Discharging current present|the presence of the discharging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |DCP|(% style="width:140px" %) |(% style="width:142px" %) 55 +|Discharging|state of the discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |DCH|(% style="width:140px" %) |(% style="width:142px" %) 56 +|External 1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |EX1|(% style="width:140px" %) |(% style="width:142px" %) 57 +|Heater (AUX)| | |Yes| |(% style="width:140px" %) |HA|(% style="width:140px" %) |(% style="width:142px" %) 58 +|Heater|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |HEA|(% style="width:140px" %) |(% style="width:142px" %) 59 59 |High charging current|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |HCC|(% style="width:140px" %) |(% style="width:142px" %) 60 60 |Init| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |INI|(% style="width:140px" %) |(% style="width:142px" %) 61 61 |Low SOC|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |LOS|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -71,13 +71,13 @@ 71 71 |Voltage too high for charging| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |ENV|(% style="width:140px" %) |(% style="width:142px" %) 72 72 73 73 (% class="wikigeneratedid" %) 74 -~* Assignable to relay only74 +~* assignable to relay only 75 75 76 76 (% class="wikigeneratedid" %) 77 -~** Assignable to discrete input only77 +~** assignable to discrete input only 78 78 79 79 (% class="wikigeneratedid" %) 80 -~*~*~* Cannot be assigned to discrete output or relay.80 +~*~*~* cannot be assigned to discrete output or relay. 81 81 82 82 == List of errors == 83 83