Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -53,15 +53,15 @@ 53 53 |Discharging (AUX)|Command to control the auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %) |AUX|(% style="width:140px" %) |(% style="width:142px" %) 54 54 |Discharging current present|Signal showing the presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |DCP|(% style="width:140px" %) |(% style="width:142px" %) 55 55 |Discharging|Command to control the discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) |DCH|(% style="width:140px" %) |(% style="width:142px" %) 56 -|External 1|Command to control an external s hc|Yes|Yes|Yes|(% style="width:140px" %) |EX1|(% style="width:140px" %) |(% style="width:142px" %)57 -|Heater (AUX)| | |Yes| |(% style="width:140px" %) |HA|(% style="width:140px" %) |(% style="width:142px" %) 58 -|Heater| a command to turnonaheater;|Yes|Yes|Yes|(% style="width:140px" %) |HEA|(% style="width:140px" %) |(% style="width:142px" %)59 -|High charging current|charging current is high ;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |HCC|(% style="width:140px" %) |(% style="width:142px" %)60 -|Init| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |INI|(% style="width:140px" %) |(% style="width:142px" %) 61 -|Low SOC| a signalcorresponding thelow SOC ofthe battery;|Yes|Yes|Yes|(% style="width:140px" %) |LOS|(% style="width:140px" %) |(% style="width:142px" %)62 -|Main contactor| stateofthe main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |MCO|(% style="width:140px" %) |(% style="width:142px" %)63 -|Power down ACK|an acknowledge mentofBMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |PDA|(% style="width:140px" %) |(% style="width:142px" %)64 -|Power up| an indicationofBMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |PUP|(% style="width:140px" %) |(% style="width:142px" %)56 +|External 1|Command to control an external scheme|Yes|Yes|Yes|(% style="width:140px" %) |EX1|(% style="width:140px" %) |(% style="width:142px" %) 57 +|Heater (AUX)|Command to control the auxiliary heater| |Yes| |(% style="width:140px" %) |HA|(% style="width:140px" %) |(% style="width:142px" %) 58 +|Heater|Command to control the heater|Yes|Yes|Yes|(% style="width:140px" %) |HEA|(% style="width:140px" %) |(% style="width:142px" %) 59 +|High charging current|Signal indicating that the charging current is high|Yes|Yes~*~*|Yes|(% style="width:140px" %) |HCC|(% style="width:140px" %) |(% style="width:142px" %) 60 +|Init|Signal showing that the device is in the initialization phase|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |INI|(% style="width:140px" %) |(% style="width:142px" %) 61 +|Low SOC|Signal indicatiing that the battery has low SOC|Yes|Yes|Yes|(% style="width:140px" %) |LOS|(% style="width:140px" %) |(% style="width:142px" %) 62 +|Main contactor|Command to control the main contactor|Yes|Yes*|Yes|(% style="width:140px" %) |MCO|(% style="width:140px" %) |(% style="width:142px" %) 63 +|Power down ACK|Command that acknowledges the BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on the power down request|Yes|Yes~*~*|Yes|(% style="width:140px" %) |PDA|(% style="width:140px" %) |(% style="width:142px" %) 64 +|Power up|Signal indicating the BMS power status|Yes|Yes|Yes|(% style="width:140px" %) |PUP|(% style="width:140px" %) |(% style="width:142px" %) 65 65 |Precharging|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |PRE|(% style="width:140px" %) |(% style="width:142px" %) 66 66 |Ready to charge|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |RTC|(% style="width:140px" %) |(% style="width:142px" %) 67 67 |Ready to discharge|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |RTD|(% style="width:140px" %) |(% style="width:142px" %)