Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -41,19 +41,19 @@ 41 41 (% style="width:1277px" %) 42 42 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 140px;" %)BMS Display|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 43 43 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation 44 -|Allow charging|Command for a charger to start charging|Yes|Yes|Yes|(% style="width:140px" %) |ACH|(% style="width:140px" %) |(% style="width:142px" %) 45 -|Balancing 1|Command to balance the first series of cells| |Yes*|Yes|(% style="width:140px" %) |BA1|(% style="width:140px" %) |(% style="width:142px" %) 46 -|Balancing 2|Command to balance the second series of cells| |Yes*|Yes|(% style="width:140px" %) |BA2|(% style="width:140px" %) |(% style="width:142px" %) 47 -|Cell analysis|Signal indicating cell analysis process|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CEA|(% style="width:140px" %) |(% style="width:142px" %) 48 -|Charging current present|Signal showing the presence of the charging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |CCP|(% style="width:140px" %) |(% style="width:142px" %) 49 -|Charging|Command to control the charging contactor|Yes|Yes*|Yes|(% style="width:140px" %) 50 -|Charging/ discharging|Command to control the charging/discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %)51 -|Cooler|Command to control the cooler|Yes|Yes|Yes|(% style="width:140px" %) 52 -|Crown EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |EWS|(% style="width:140px" %) |(% style="width:142px" %) 53 -|Discharging (AUX)|Command to control the auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %) |AUX|(% style="width:140px" %) |(% style="width:142px" %) 54 -|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %) |DCP|(% style="width:140px" %) |(% style="width:142px" %) 55 -|Discharging|Command to control the discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %) 56 -|External 1|Command to control an external scheme|Yes|Yes|Yes|(% style="width:140px" %) |EX1|(% style="width:140px" %) |(% style="width:142px" %) 44 +|Allow charging|Command for a charger to start charging|Yes|Yes|Yes|(% style="width:140px" %)Allow charging|ACH|(% style="width:140px" %) |(% style="width:142px" %) 45 +|Balancing 1|Command to balance the first series of cells| |Yes*|Yes|(% style="width:140px" %)Balancing 1|BA1|(% style="width:140px" %) |(% style="width:142px" %) 46 +|Balancing 2|Command to balance the second series of cells| |Yes*|Yes|(% style="width:140px" %)Balancing 2|BA2|(% style="width:140px" %) |(% style="width:142px" %) 47 +|Cell analysis|Signal indicating cell analysis process|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Cell analysis|CEA|(% style="width:140px" %) |(% style="width:142px" %) 48 +|Charging current present|Signal showing the presence of the charging current|Yes|Yes~*~*|Yes|(% style="width:140px" %)CH curr. present|CCP|(% style="width:140px" %) |(% style="width:142px" %) 49 +|Charging|Command to control the charging contactor|Yes|Yes*|Yes|(% style="width:140px" %)Charging|CH|(% style="width:140px" %) |(% style="width:142px" %) 50 +|Charging/Discharging|Command to control the charging/discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %)Charg./Discharg.|C/D|(% style="width:140px" %) |(% style="width:142px" %) 51 +|Cooler|Command to control the cooler|Yes|Yes|Yes|(% style="width:140px" %)Cooler|COO|(% style="width:140px" %) |(% style="width:142px" %) 52 +|Crown EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Crown EWS|EWS|(% style="width:140px" %) |(% style="width:142px" %) 53 +|Discharging (AUX)|Command to control the auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Disch. AUX|AUX|(% style="width:140px" %) |(% style="width:142px" %) 54 +|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %)DCH curr. pres.|DCP|(% style="width:140px" %) |(% style="width:142px" %) 55 +|Discharging|Command to control the discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %)Discharging|DCH|(% style="width:140px" %) |(% style="width:142px" %) 56 +|External 1|Command to control an external scheme|Yes|Yes|Yes|(% style="width:140px" %)External 1|EX1|(% style="width:140px" %) |(% style="width:142px" %) 57 57 |Heater (AUX)|Command to control the auxiliary heater| |Yes| |(% style="width:140px" %) |HA|(% style="width:140px" %) |(% style="width:142px" %) 58 58 |Heater|Command to control the heater|Yes|Yes|Yes|(% style="width:140px" %) |HEA|(% style="width:140px" %) |(% style="width:142px" %) 59 59 |High charging current|Signal indicating that the charging current is high|Yes|Yes~*~*|Yes|(% style="width:140px" %) |HCC|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -64,11 +64,11 @@ 64 64 |Power up|Signal indicating the BMS power status|Yes|Yes|Yes|(% style="width:140px" %) |PUP|(% style="width:140px" %) |(% style="width:142px" %) 65 65 |Precharging|Command to control the precharging contactor|Yes|Yes|Yes|(% style="width:140px" %) |PRE|(% style="width:140px" %) |(% style="width:142px" %) 66 66 |Ready to charge|Signal showing that the battery is ready for charging|Yes|Yes|Yes|(% style="width:140px" %) |RTC|(% style="width:140px" %) |(% style="width:142px" %) 67 -|Ready to discharge|Signal showing thathe battery is ready tobedischarged;|Yes|Yes|Yes|(% style="width:140px" %) |RTD|(% style="width:140px" %) |(% style="width:142px" %)68 -|Service reset| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |SR|(% style="width:140px" %) |(% style="width:142px" %) 69 -|Shutdown request (Combilift)| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CSH|(% style="width:140px" %) |(% style="width:142px" %) 70 -|Shutdown request (HYG/Spirit)| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |HSH|(% style="width:140px" %) |(% style="width:142px" %) 71 -|Voltage too high for charging| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |ENV|(% style="width:140px" %) |(% style="width:142px" %) 67 +|Ready to discharge|Signal showing that the battery is ready for discharging|Yes|Yes|Yes|(% style="width:140px" %) |RTD|(% style="width:140px" %) |(% style="width:142px" %) 68 +|Service reset|Command to restart the device|Yes~*~**| |Yes~*~**|(% style="width:140px" %) |SR|(% style="width:140px" %) |(% style="width:142px" %) 69 +|Shutdown request (Combilift)|Command to open the dischrging contactor from the Combilift truck|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CSH|(% style="width:140px" %) |(% style="width:142px" %) 70 +|Shutdown request (HYG/Spirit)|Command to open the dischrging contactor from the HYG truck|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |HSH|(% style="width:140px" %) |(% style="width:142px" %) 71 +|Voltage too high for charging|Signal indicating that the battery is fully charged|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |ENV|(% style="width:140px" %) |(% style="width:142px" %) 72 72 73 73 (% class="wikigeneratedid" %) 74 74 ~* Assignable to relay only