... ... @@ -58,12 +58,12 @@
58 58  |Heater|Command to control the heater|Yes|Yes|Yes|(% style="width:140px" %) |HEA|(% style="width:140px" %) |(% style="width:142px" %)
59 59  |High charging current|Signal indicating that the charging current is high|Yes|Yes~*~*|Yes|(% style="width:140px" %) |HCC|(% style="width:140px" %) |(% style="width:142px" %)
60 60  |Init|Signal showing that the device is in the initialization phase|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |INI|(% style="width:140px" %) |(% style="width:142px" %)
61 -|Low SOC|Signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |LOS|(% style="width:140px" %) |(% style="width:142px" %)
62 -|Main contactor|state of the main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |MCO|(% style="width:140px" %) |(% style="width:142px" %)
63 -|Power down ACK|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |PDA|(% style="width:140px" %) |(% style="width:142px" %)
64 -|Power up|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |PUP|(% style="width:140px" %) |(% style="width:142px" %)
65 -|Precharging|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |PRE|(% style="width:140px" %) |(% style="width:142px" %)
66 -|Ready to charge|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |RTC|(% style="width:140px" %) |(% style="width:142px" %)
61 +|Low SOC|Signal indicatiing that the battery has low SOC|Yes|Yes|Yes|(% style="width:140px" %) |LOS|(% style="width:140px" %) |(% style="width:142px" %)
62 +|Main contactor|Command to control the main contactor|Yes|Yes*|Yes|(% style="width:140px" %) |MCO|(% style="width:140px" %) |(% style="width:142px" %)
63 +|Power down ACK|Command that acknowledges the BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on the power down request|Yes|Yes~*~*|Yes|(% style="width:140px" %) |PDA|(% style="width:140px" %) |(% style="width:142px" %)
64 +|Power up|Signal indicating the BMS power status|Yes|Yes|Yes|(% style="width:140px" %) |PUP|(% style="width:140px" %) |(% style="width:142px" %)
65 +|Precharging|Command to control the precharging contactor|Yes|Yes|Yes|(% style="width:140px" %) |PRE|(% style="width:140px" %) |(% style="width:142px" %)
66 +|Ready to charge|Signal showing that the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |RTC|(% style="width:140px" %) |(% style="width:142px" %)
67 67  |Ready to discharge|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |RTD|(% style="width:140px" %) |(% style="width:142px" %)
68 68  |Service reset| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |SR|(% style="width:140px" %) |(% style="width:142px" %)
69 69  |Shutdown request (Combilift)| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |CSH|(% style="width:140px" %) |(% style="width:142px" %)