- Content
-
... ... @@ -57,11 +57,11 @@ 57 57 |Heater (AUX)|Command to control the auxiliary heater| |Yes| |(% style="width:140px" %) |HA|(% style="width:140px" %) |(% style="width:142px" %) 58 58 |Heater|Command to control the heater|Yes|Yes|Yes|(% style="width:140px" %) |HEA|(% style="width:140px" %) |(% style="width:142px" %) 59 59 |High charging current|Signal indicating that the charging current is high|Yes|Yes~*~*|Yes|(% style="width:140px" %) |HCC|(% style="width:140px" %) |(% style="width:142px" %) 60 -|Init|Signal showing that the device is in the initializ|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |INI|(% style="width:140px" %) |(% style="width:142px" %) 61 -|Low SOC| a signalcorresponding thelow SOC ofthe battery;|Yes|Yes|Yes|(% style="width:140px" %) |LOS|(% style="width:140px" %) |(% style="width:142px" %)62 -|Main contactor| stateofthe main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |MCO|(% style="width:140px" %) |(% style="width:142px" %)63 -|Power down ACK|an acknowledge mentofBMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |PDA|(% style="width:140px" %) |(% style="width:142px" %)64 -|Power up| an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |PUP|(% style="width:140px" %) |(% style="width:142px" %)60 +|Init|Signal showing that the device is in the initialization phase|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |INI|(% style="width:140px" %) |(% style="width:142px" %) 61 +|Low SOC|Signal indicatiing that the battery has low SOC|Yes|Yes|Yes|(% style="width:140px" %) |LOS|(% style="width:140px" %) |(% style="width:142px" %) 62 +|Main contactor|Command to control the main contactor|Yes|Yes*|Yes|(% style="width:140px" %) |MCO|(% style="width:140px" %) |(% style="width:142px" %) 63 +|Power down ACK|Command that acknowledges the BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on the power down request|Yes|Yes~*~*|Yes|(% style="width:140px" %) |PDA|(% style="width:140px" %) |(% style="width:142px" %) 64 +|Power up|Signal indicating of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |PUP|(% style="width:140px" %) |(% style="width:142px" %) 65 65 |Precharging|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |PRE|(% style="width:140px" %) |(% style="width:142px" %) 66 66 |Ready to charge|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |RTC|(% style="width:140px" %) |(% style="width:142px" %) 67 67 |Ready to discharge|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |RTD|(% style="width:140px" %) |(% style="width:142px" %)