Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - Signals,states and errors1 +3.1 - Content
-
... ... @@ -1,7 +1,10 @@ 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 3 + 1 1 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Signals,states anderrors=5 +== General information == 3 3 4 -== List of input signals == 7 +=== List of input signals === 5 5 6 6 Here is the list of input signals that can be assigned to discrete inputs of BMS controller. 7 7 ... ... @@ -34,7 +34,7 @@ 34 34 (% class="wikigeneratedid" %) 35 35 ~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section. 36 36 37 -== List of internal states == 40 +=== List of internal states === 38 38 39 39 Here is the list of control internal states. Signals marked with bold text can be assigned to discrete output or relay. 40 40 ... ... @@ -77,9 +77,9 @@ 77 77 ~** assignable to discrete input only 78 78 79 79 (% class="wikigeneratedid" %) 80 -~*~*~* cannot be assigned to discrete output or relay. 83 +~*~*~* state is indicative only and cannot be assigned to discrete output or relay. 81 81 82 -== List of errors == 85 +=== List of errors === 83 83 84 84 (% style="width:1279px" %) 85 85 |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:58px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus** ... ... @@ -91,10 +91,10 @@ 91 91 |CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 92 |CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 93 |Combilift offline|COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 94 -|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be foundin "Signals -> MOSFETs -> Contactor feedback"section of BMS Mini device| |Yes|| |(% style="width:142px" %) |(% style="width:134px" %)97 +|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be | |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %) 95 95 |Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 96 96 |Crown error|CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 97 -|Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 +|Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 98 98 |Current sensor error|CSE|error in the current sensor circuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 99 |DCH contactor cycles error|DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 100 |DCH contactor feedback error|DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -122,9 +122,9 @@ 122 122 |Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 123 123 |Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 124 |PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 125 -|Power fault|PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 128 +|Power fault|PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 126 126 |Power switch error|PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 127 -|Precharge error|PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 130 +|Precharge error|PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 128 128 |Settings error|SET| | | | | |(% style="width:142px" %) |(% style="width:134px" %) 129 129 |Short circuit|SHC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 130 130 |Shunt error|SHE|internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)