Last modified by Admin on 2025/02/21 14:51

From version 11.9
edited by Admin
on 2025/01/30 17:03
Change comment: There is no comment for this version
To version 11.14
edited by Admin
on 2025/01/30 17:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -91,27 +91,27 @@
91 91  |Battery cover error|BC|battery cover is open;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
92 92  |Cell count error|CEL|number of cells does not match the specified value;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
93 93  |CH contactor cycles error|CCC|switching frequency of the charging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
94 -|CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
95 -|CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
94 +|CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
95 +|CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
96 96  |Combilift offline|COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
97 97  |Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be | |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)
98 98  |Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
99 99  |Crown error|CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
100 -|Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)
100 +|Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
101 101  |Current sensor error|CSE|error in the current sensor circuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
102 102  |DCH contactor cycles error|DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
103 -|DCH contactor feedback error|DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
104 -|FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
105 -|General error|GE| | |Yes*|Yes*|Yes*|(% style="width:142px" %) |(% style="width:134px" %)
103 +|DCH contactor feedback error|DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
104 +|FS error|FSE| | |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
105 +|General error|GE| | |Yes*|Yes*|**Yes***|(% style="width:142px" %) |(% style="width:134px" %)
106 106  |High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
107 107  |High humidity|HH|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
108 108  |High Logic temperature|LHT|at least one of the Logic devices is overheated;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
109 109  |High temperature (CH)|HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
110 110  |High temperature (DCH)|HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
111 -|High voltage fault|HVF|failure of high voltage measuring circuits;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
112 -|HVIL error|HE|breakage of high-voltage interlock current loop;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
111 +|High voltage fault|HVF|failure of high voltage measuring circuits;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
112 +|HVIL error|HE|breakage of high-voltage interlock current loop;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
113 113  |HYG offline|HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
114 -|Insulation fault|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
114 +|Insulation fault|INF| |•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
115 115  |Logic count error|LOG| | | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
116 116  |Logic offline
117 117  Cell monitor offline|LOF|BMS Main devices: at least one of the Logic devices is offline;
... ... @@ -118,24 +118,24 @@
118 118  BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
119 119  |Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
120 120  |Low temperature (DCH)|LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
121 -|Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
122 -|Mount error|MNT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
121 +|Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
122 +|Mount error|MNT| | |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
123 123  |Need acknowledge|ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
124 124  |No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
125 125  |Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
126 126  |Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
127 -|PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
128 -|Power fault|PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
129 -|Power switch error|PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
130 -|Precharge error|PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
127 +|PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
128 +|Power fault|PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
129 +|Power switch error|PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
130 +|Precharge error|PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
131 131  |Settings error|SET| | | | | |(% style="width:142px" %) |(% style="width:134px" %)
132 132  |Short circuit|SHC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
133 133  |Shunt error|SHE|internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
134 134  |Shunt offline|SHO|connection with the shunt current sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
135 135  |Spirit offline|SPI|connection with a Spirit forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
136 -|Stuck contactor|STC| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
136 +|Stuck contactor|STC| |•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
137 137  |Temperature sensor is shorted|TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
138 -|Unallowable charging|UCH|charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
138 +|Unallowable charging|UCH|charging the battery through the discharging contactor;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %)
139 139  |Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
140 140  |Water|WA|there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
141 141  |WDT reset|WDT|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)