... ... @@ -94,7 +94,7 @@
94 94  |CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
95 95  |CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
96 96  |Combilift offline|COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
97 -|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be | |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)
97 +|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of BMS Mini device| |Yes| | |(% style="width:142px" %) |(% style="width:134px" %)
98 98  |Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
99 99  |Crown error|CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
100 100  |Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)
... ... @@ -113,8 +113,9 @@
113 113  |HYG offline|HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
114 114  |Insulation fault|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
115 115  |Logic count error|LOG| | | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
116 -|Logic offline|LOF|at least one of the Logic devices is offline;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
117 -|Cell monitor offline|LOF|connection with cell monitor lost.|•|Yes| | |(% style="width:142px" %) |(% style="width:134px" %)
116 +|Logic offline
117 +Cell monitor offline|LOF|BMS Main devices: at least one of the Logic devices is offline;
118 +BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
118 118  |Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
119 119  |Low temperature (DCH)|LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
120 120  |Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)