Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -89,13 +89,13 @@ 89 89 |=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3** 90 90 |ADC error|ADC|current cannot be measured;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 91 91 |Battery cover error|BC|battery cover is open;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 -|Cell count error|CEL|number of cells does not match the specified value;|•|Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)92 +|Cell count error|CEL|number of cells does not match the specified value;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 93 |CH contactor cycles error|CCC|switching frequency of the charging contactor is too high;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 94 94 |CH contactor feedback error|CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 95 95 |CH/DCH contactor feedback error|CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 96 96 |Combilift offline|COM|connection with a Combilift forklift is lost;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 97 97 |Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be | |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %) 98 -|Critical error|CER| | |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)98 +|Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 99 |Crown error|CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 100 |Current limit error|CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 101 101 |Current sensor error|CSE|error in the current sensor circuit;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -104,10 +104,10 @@ 104 104 |FS error|FSE| | |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 105 105 |General error|GE| | |Yes*|Yes*|**Yes***|(% style="width:142px" %) |(% style="width:134px" %) 106 106 |High contactor temperature|CHT| | |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 107 -|High humidity|HH|humidity of the battery is increased;| | |Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)108 -|High Logic temperature|LHT|at least one of the Logic devices is overheated;| | |Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)107 +|High humidity|HH|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 +|High Logic temperature|LHT|at least one of the Logic devices is overheated;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 109 |High temperature (CH)|HCT|temperature is too high for charging;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 110 -|High temperature (DCH)|HDT|temperature is too high for discharging;| |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)110 +|High temperature (DCH)|HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 111 |High voltage fault|HVF|failure of high voltage measuring circuits;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 112 112 |HVIL error|HE|breakage of high-voltage interlock current loop;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 113 113 |HYG offline|HYG|connection with a HYG forklift is lost;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -115,15 +115,15 @@ 115 115 |Logic count error|LOG| | | |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 116 116 |Logic offline 117 117 Cell monitor offline|LOF|BMS Main devices: at least one of the Logic devices is offline; 118 -BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)118 +BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 119 |Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 120 -|Low temperature (DCH)|LDT|temperature is too low for discharging;| |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)120 +|Low temperature (DCH)|LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 121 121 |Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 122 122 |Mount error|MNT| | |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 123 123 |Need acknowledge|ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 124 124 |No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 125 -|Overcurrent|OC| | |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)126 -|Overvoltage|OV| | |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)125 +|Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 126 +|Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 127 127 |PCH contactor feedback error|PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 128 128 |Power fault|PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 129 129 |Power switch error|PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -136,8 +136,8 @@ 136 136 |Stuck contactor|STC| |•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 137 137 |Temperature sensor is shorted|TSS|some temperature sensors are shorted;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 138 138 |Unallowable charging|UCH|charging the battery through the discharging contactor;| |Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 139 -|Undervoltage|UV| | |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)140 -|Water|WA|there is water in the battery enclosure;|•| |Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)139 +|Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 140 +|Water|WA|there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 141 141 |WDT reset|WDT|watchdog timer reset the device;|•|Yes|Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 142 142 143 143 ~* signal can be assigned to a discrete output and relay.