Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -101,12 +101,12 @@ 101 101 |Current sensor error|CSE|error in the current sensor circuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 102 |DCH contactor cycles error|DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 103 |DCH contactor feedback error|DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 104 -|FS error|FSE| | |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)104 +|FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 105 105 |General error|GE| | |Yes*|Yes*|**Yes***|(% style="width:142px" %) |(% style="width:134px" %) 106 106 |High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 107 |High humidity|HH|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 108 |High Logic temperature|LHT|at least one of the Logic devices is overheated;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 -|High temperature (CH)|HCT|temperature is too high for charging;| |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)109 +|High temperature (CH)|HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 110 110 |High temperature (DCH)|HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 111 |High voltage fault|HVF|failure of high voltage measuring circuits;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 112 112 |HVIL error|HE|breakage of high-voltage interlock current loop;|•| | |**Yes**|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -116,10 +116,10 @@ 116 116 |Logic offline 117 117 Cell monitor offline|LOF|BMS Main devices: at least one of the Logic devices is offline; 118 118 BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 -|Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)119 +|Low temperature (CH)|LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 120 120 |Low temperature (DCH)|LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 121 121 |Main contactor feedback error|MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|**Yes**|(% style="width:142px" %) |(% style="width:134px" %) 122 -|Mount error|MNT| | |Yes|Yes| **Yes**|(% style="width:142px" %) |(% style="width:134px" %)122 +|Mount error|MNT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 123 123 |Need acknowledge|ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 124 |No temperature sensors|NTS|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 125 125 |Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)