Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -66,18 +66,18 @@ 66 66 67 67 68 68 (% style="width:1177px" %) 69 -|Name |(% style="width:432px" %)Description|(% style="width:228px" %)Set up by|(% style="width:145px" %) IsCriticalerror?|(% style="width:145px" %)69 +|Name |(% style="width:432px" %)Description|(% style="width:228px" %)Set up by|(% style="width:145px" %)Used by|(% style="width:145px" %) 70 70 |Overcurrent|(% style="width:432px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %) 71 71 |Undervoltage|(% style="width:432px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 72 72 |Overvoltage|(% style="width:432px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 73 73 |Low temperature (DCH) |(% style="width:432px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 74 74 |High temperature (DCH) |(% style="width:432px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 75 -|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %) Yes|(% style="width:145px" %)75 +|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %) |(% style="width:145px" %) 76 76 |High humidity |(% style="width:432px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %) 77 -|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %) Yes|(% style="width:145px" %)77 +|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %) |(% style="width:145px" %) 78 78 |High Logic temperature |(% style="width:432px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 79 -|Logic offline |(% style="width:432px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %) Yes|(% style="width:145px" %)80 -|Critical error|(% style="width:432px" %) |(% style="width:228px" %)Critical error|(% style="width:145px" %) |(% style="width:145px" %) 79 +|Logic offline |(% style="width:432px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %) |(% style="width:145px" %) 80 +|Critical error|(% style="width:432px" %) |(% style="width:228px" %)Critical error protection|(% style="width:145px" %) |(% style="width:145px" %) 81 81 |Crown error |(% style="width:432px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 82 82 |Cell count error |(% style="width:432px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count protection|(% style="width:145px" %) |(% style="width:145px" %) 83 83 |HYG offline |(% style="width:432px" %) connection with a HYG forklift is lost;|(% style="width:228px" %)HYG Class I-III truck|(% style="width:145px" %) |(% style="width:145px" %) ... ... @@ -99,18 +99,18 @@ 99 99 |High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 100 100 |Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:228px" %)Unallowable charging protection|(% style="width:145px" %) |(% style="width:145px" %) 101 101 |Stuck contactor|(% style="width:432px" %) |(% style="width:228px" %)Stuck contactor protection|(% style="width:145px" %) |(% style="width:145px" %) 102 -|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback prote ction|(% style="width:145px" %) |(% style="width:145px" %)103 -|DCH contactor feedback error |(% style="width:432px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:228px" %) Contactorfeedback protection|(% style="width:145px" %) |(% style="width:145px" %)104 -|Insulation fault;|(% style="width:432px" %) |(% style="width:228px" %) Insulationprotection|(% style="width:145px" %) |(% style="width:145px" %)105 -|PCH contactor feedback error |(% style="width:432px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:228px" %) Contactorfeedback protection|(% style="width:145px" %) |(% style="width:145px" %)106 -|CH/DCH contactor feedback error |(% style="width:432px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:228px" %) Contactorfeedback protection|(% style="width:145px" %) |(% style="width:145px" %)107 -|Main contactor feedback error |(% style="width:432px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:228px" %) Contactorfeedback protection|(% style="width:145px" %) |(% style="width:145px" %)108 -|General error|(% style="width:432px" %) |(% style="width:228px" %) Generalerror|(% style="width:145px" %) |(% style="width:145px" %)109 -|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:228px" %) Highvoltage controller|(% style="width:145px" %) |(% style="width:145px" %)102 +|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback prote|(% style="width:145px" %) |(% style="width:145px" %) 103 +|DCH contactor feedback error |(% style="width:432px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 104 +|Insulation fault;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 105 +|PCH contactor feedback error |(% style="width:432px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 106 +|CH/DCH contactor feedback error |(% style="width:432px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 107 +|Main contactor feedback error |(% style="width:432px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 108 +|General error|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 109 +|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 110 110 |Power switch error |(% style="width:432px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 111 -|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %) HVILprotection|(% style="width:145px" %) |(% style="width:145px" %)112 -|Precharge error |(% style="width:432px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:228px" %) Prechargecontroller|(% style="width:145px" %) |(% style="width:145px" %)111 +|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 112 +|Precharge error |(% style="width:432px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 113 113 |Power fault |(% style="width:432px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 114 -|Current limit error |(% style="width:432px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:228px" %) Chargecurrent limit protection, Discharge current limit protection|(% style="width:145px" %) |(% style="width:145px" %)114 +|Current limit error |(% style="width:432px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 115 115 116 116