Last modified by Admin on 2025/02/21 14:51

From version 1.79
edited by Admin
on 2025/01/29 17:38
Change comment: There is no comment for this version
To version 1.81
edited by Admin
on 2025/01/29 17:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -90,16 +90,16 @@
90 90  |CH contactor cycles error |(% style="width:432px" %) switching frequency of the charging contactor is too high;|(% style="width:228px" %)Charge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %)
91 91  |DCH contactor cycles error |(% style="width:432px" %) switching frequency of the discharging contactor is too high;|(% style="width:228px" %)Discharge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %)
92 92  |Shunt offline |(% style="width:432px" %) connection with the shunt current sensor is lost;|(% style="width:228px" %)Shunt sensor (CAN bus)|(% style="width:145px" %) |(% style="width:145px" %)
93 -|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
94 -|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
95 -|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
96 -|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
97 -|Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
93 +|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:228px" %)Shunt sensor (CAN bus)|(% style="width:145px" %) |(% style="width:145px" %)
94 +|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:228px" %)WDT reset protection|(% style="width:145px" %) |(% style="width:145px" %)
95 +|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:228px" %)Temperature sensors protection|(% style="width:145px" %) |(% style="width:145px" %)
96 +|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:228px" %)Temperature sensors protection|(% style="width:145px" %) |(% style="width:145px" %)
97 +|Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:228px" %)Spirit AGV truck|(% style="width:145px" %) |(% style="width:145px" %)
98 98  |Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
99 99  |High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
100 -|Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
101 -|Stuck contactor;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
102 -|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
100 +|Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:228px" %)Unallowable charging protection|(% style="width:145px" %) |(% style="width:145px" %)
101 +|Stuck contactor|(% style="width:432px" %) |(% style="width:228px" %)Stuck contactor protection|(% style="width:145px" %) |(% style="width:145px" %)
102 +|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback prote|(% style="width:145px" %) |(% style="width:145px" %)
103 103  |DCH contactor feedback error |(% style="width:432px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
104 104  |Insulation fault;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
105 105  |PCH contactor feedback error |(% style="width:432px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)