... ... @@ -65,52 +65,51 @@
65 65  Here is the list of error of BMS Main 3.
66 66  
67 67  
68 -(% style="width:1177px" %)
69 -|Name |(% style="width:432px" %)Description|(% style="width:228px" %)Set up by|(% style="width:145px" %)Used by|(% style="width:145px" %)
70 -|Overcurrent|(% style="width:432px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %)
71 -|Undervoltage|(% style="width:432px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
72 -|Overvoltage|(% style="width:432px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
73 -|Low temperature (DCH) |(% style="width:432px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
74 -|High temperature (DCH) |(% style="width:432px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
75 -|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %) |(% style="width:145px" %)
76 -|High humidity |(% style="width:432px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %)
77 -|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %) |(% style="width:145px" %)
78 -|High Logic temperature |(% style="width:432px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
79 -|Logic offline |(% style="width:432px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %) |(% style="width:145px" %)
80 -|Critical error|(% style="width:432px" %) |(% style="width:228px" %)Critical error protection|(% style="width:145px" %) |(% style="width:145px" %)
81 -|Crown error |(% style="width:432px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
82 -|Cell count error |(% style="width:432px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count protection|(% style="width:145px" %) |(% style="width:145px" %)
83 -|HYG offline |(% style="width:432px" %) connection with a HYG forklift is lost;|(% style="width:228px" %)HYG Class I-III truck|(% style="width:145px" %) |(% style="width:145px" %)
84 -|Need acknowledge |(% style="width:432px" %) there is an unacknowledged error in Error journal;|(% style="width:228px" %)Error journal|(% style="width:145px" %) |(% style="width:145px" %)
85 -|Combilift offline |(% style="width:432px" %) connection with a Combilift forklift is lost;|(% style="width:228px" %)Combilift truck|(% style="width:145px" %) |(% style="width:145px" %)
86 -|Short circuit|(% style="width:432px" %) |(% style="width:228px" %)Short circuit protection|(% style="width:145px" %) |(% style="width:145px" %)
87 -|High contactor temperature|(% style="width:432px" %) |(% style="width:228px" %)High contactor temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
88 -|ADC error |(% style="width:432px" %) current cannot be measured;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
89 -|Current sensor error |(% style="width:432px" %) error in the current sensor circuit;|(% style="width:228px" %)Current sensor protection|(% style="width:145px" %) |(% style="width:145px" %)
90 -|CH contactor cycles error |(% style="width:432px" %) switching frequency of the charging contactor is too high;|(% style="width:228px" %)Charge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %)
91 -|DCH contactor cycles error |(% style="width:432px" %) switching frequency of the discharging contactor is too high;|(% style="width:228px" %)Discharge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %)
92 -|Shunt offline |(% style="width:432px" %) connection with the shunt current sensor is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
93 -|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
94 -|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
95 -|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
96 -|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
97 -|Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
98 -|Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
99 -|High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
100 -|Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
101 -|Stuck contactor;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
102 -|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
103 -|DCH contactor feedback error |(% style="width:432px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
104 -|Insulation fault;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
105 -|PCH contactor feedback error |(% style="width:432px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
106 -|CH/DCH contactor feedback error |(% style="width:432px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
107 -|Main contactor feedback error |(% style="width:432px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
108 -|General error|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
109 -|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
110 -|Power switch error |(% style="width:432px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
111 -|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
112 -|Precharge error |(% style="width:432px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
113 -|Power fault |(% style="width:432px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
114 -|Current limit error |(% style="width:432px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
68 +|Name |(% style="width:432px" %)Description|(% style="width:190px" %)Set up by|(% style="width:183px" %)Used by|
69 +|Overcurrent|(% style="width:432px" %) |(% style="width:190px" %)Overcurrent protection|(% style="width:183px" %) |
70 +|Undervoltage|(% style="width:432px" %) |(% style="width:190px" %)Undervoltage protection|(% style="width:183px" %) |
71 +|Overvoltage|(% style="width:432px" %) |(% style="width:190px" %)Overvoltage protection|(% style="width:183px" %) |
72 +|Low temperature (DCH) |(% style="width:432px" %) temperature is too low for discharging;|(% style="width:190px" %) |(% style="width:183px" %) |
73 +|High temperature (DCH) |(% style="width:432px" %) temperature is too high for discharging;|(% style="width:190px" %) |(% style="width:183px" %) |
74 +|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:190px" %) |(% style="width:183px" %) |
75 +|High humidity |(% style="width:432px" %) humidity of the battery is increased;|(% style="width:190px" %) |(% style="width:183px" %) |
76 +|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:190px" %) |(% style="width:183px" %) |
77 +|High Logic temperature |(% style="width:432px" %) at least one of the Logic devices is overheated;|(% style="width:190px" %) |(% style="width:183px" %) |
78 +|Logic offline |(% style="width:432px" %) at least one of the Logic devices is offline;|(% style="width:190px" %) |(% style="width:183px" %) |
79 +|Critical error;|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) |
80 +|Crown error |(% style="width:432px" %) connection with a Crown forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) |
81 +|Cell count error |(% style="width:432px" %) number of cells does not match the specified value;|(% style="width:190px" %) |(% style="width:183px" %) |
82 +|HYG offline |(% style="width:432px" %) connection with a HYG forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) |
83 +|Need acknowledge |(% style="width:432px" %) there is an unacknowledged error in Error journal;|(% style="width:190px" %) |(% style="width:183px" %) |
84 +|Combilift offline |(% style="width:432px" %) connection with a Combilift forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) |
85 +|Short circuit|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) |
86 +|High contactor temperature|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) |
87 +|ADC error |(% style="width:432px" %) current cannot be measured;|(% style="width:190px" %) |(% style="width:183px" %) |
88 +|Current sensor error |(% style="width:432px" %) error in the current sensor circuit;|(% style="width:190px" %) |(% style="width:183px" %) |
89 +|CH contactor cycles error |(% style="width:432px" %) switching frequency of the charging contactor is too high;|(% style="width:190px" %) |(% style="width:183px" %) |
90 +|DCH contactor cycles error |(% style="width:432px" %) switching frequency of the discharging contactor is too high;|(% style="width:190px" %) |(% style="width:183px" %) |
91 +|Shunt offline |(% style="width:432px" %) connection with the shunt current sensor is lost;|(% style="width:190px" %) |(% style="width:183px" %) |
92 +|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:190px" %) |(% style="width:183px" %) |
93 +|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:190px" %) |(% style="width:183px" %) |
94 +|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:190px" %) |(% style="width:183px" %) |
95 +|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:190px" %) |(% style="width:183px" %) |
96 +|Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) |
97 +|Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:190px" %) |(% style="width:183px" %) |
98 +|High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:190px" %) |(% style="width:183px" %) |
99 +|Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:190px" %) |(% style="width:183px" %) |
100 +|Stuck contactor;|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) |
101 +|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) |
102 +|DCH contactor feedback error |(% style="width:432px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) |
103 +|Insulation fault;|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) |
104 +|PCH contactor feedback error |(% style="width:432px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) |
105 +|CH/DCH contactor feedback error |(% style="width:432px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) |
106 +|Main contactor feedback error |(% style="width:432px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) |
107 +|General error|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) |
108 +|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:190px" %) |(% style="width:183px" %) |
109 +|Power switch error |(% style="width:432px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:190px" %) |(% style="width:183px" %) |
110 +|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:190px" %) |(% style="width:183px" %) |
111 +|Precharge error |(% style="width:432px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:190px" %) |(% style="width:183px" %) |
112 +|Power fault |(% style="width:432px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:190px" %) |(% style="width:183px" %) |
113 +|Current limit error |(% style="width:432px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:190px" %) |(% style="width:183px" %) |
115 115  
116 116