Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -65,52 +65,51 @@ 65 65 Here is the list of error of BMS Main 3. 66 66 67 67 68 -(% style="width:1177px" %) 69 -|Name |(% style="width:432px" %)Description|(% style="width:228px" %)Set up by|(% style="width:145px" %)Used by|(% style="width:145px" %) 70 -|Overcurrent|(% style="width:432px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %) 71 -|Undervoltage|(% style="width:432px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 72 -|Overvoltage|(% style="width:432px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 73 -|Low temperature (DCH) |(% style="width:432px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 74 -|High temperature (DCH) |(% style="width:432px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 75 -|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %) |(% style="width:145px" %) 76 -|High humidity |(% style="width:432px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %) 77 -|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %) |(% style="width:145px" %) 78 -|High Logic temperature |(% style="width:432px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 79 -|Logic offline |(% style="width:432px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %) |(% style="width:145px" %) 80 -|Critical error|(% style="width:432px" %) |(% style="width:228px" %)Critical error protection|(% style="width:145px" %) |(% style="width:145px" %) 81 -|Crown error |(% style="width:432px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 82 -|Cell count error |(% style="width:432px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count error|(% style="width:145px" %) |(% style="width:145px" %) 83 -|HYG offline |(% style="width:432px" %) connection with a HYG forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 84 -|Need acknowledge |(% style="width:432px" %) there is an unacknowledged error in Error journal;|(% style="width:228px" %)Error journal|(% style="width:145px" %) |(% style="width:145px" %) 85 -|Combilift offline |(% style="width:432px" %) connection with a Combilift forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 86 -|Short circuit|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 87 -|High contactor temperature|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 88 -|ADC error |(% style="width:432px" %) current cannot be measured;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 89 -|Current sensor error |(% style="width:432px" %) error in the current sensor circuit;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 90 -|CH contactor cycles error |(% style="width:432px" %) switching frequency of the charging contactor is too high;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 91 -|DCH contactor cycles error |(% style="width:432px" %) switching frequency of the discharging contactor is too high;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 92 -|Shunt offline |(% style="width:432px" %) connection with the shunt current sensor is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 93 -|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 94 -|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 95 -|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 96 -|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 97 -|Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 98 -|Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 99 -|High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 100 -|Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 101 -|Stuck contactor;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 102 -|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 103 -|DCH contactor feedback error |(% style="width:432px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 104 -|Insulation fault;|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 105 -|PCH contactor feedback error |(% style="width:432px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 106 -|CH/DCH contactor feedback error |(% style="width:432px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 107 -|Main contactor feedback error |(% style="width:432px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 108 -|General error|(% style="width:432px" %) |(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 109 -|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 110 -|Power switch error |(% style="width:432px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 111 -|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 112 -|Precharge error |(% style="width:432px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 113 -|Power fault |(% style="width:432px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 114 -|Current limit error |(% style="width:432px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 68 +|Name |(% style="width:432px" %)Description|(% style="width:190px" %)Set up by|(% style="width:183px" %)Used by| 69 +|Overcurrent|(% style="width:432px" %) |(% style="width:190px" %)Overcurrent protection|(% style="width:183px" %) | 70 +|Undervoltage|(% style="width:432px" %) |(% style="width:190px" %)Undervoltage protection|(% style="width:183px" %) | 71 +|Overvoltage|(% style="width:432px" %) |(% style="width:190px" %)Overvoltage protection|(% style="width:183px" %) | 72 +|Low temperature (DCH) |(% style="width:432px" %) temperature is too low for discharging;|(% style="width:190px" %)Low temperature protection|(% style="width:183px" %) | 73 +|High temperature (DCH) |(% style="width:432px" %) temperature is too high for discharging;|(% style="width:190px" %)High temperature protection|(% style="width:183px" %) | 74 +|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:190px" %)Battery cover protection|(% style="width:183px" %) | 75 +|High humidity |(% style="width:432px" %) humidity of the battery is increased;|(% style="width:190px" %)High humidity protection|(% style="width:183px" %) | 76 +|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:190px" %)Water protection|(% style="width:183px" %) | 77 +|High Logic temperature |(% style="width:432px" %) at least one of the Logic devices is overheated;|(% style="width:190px" %)Logic h|(% style="width:183px" %) | 78 +|Logic offline |(% style="width:432px" %) at least one of the Logic devices is offline;|(% style="width:190px" %) |(% style="width:183px" %) | 79 +|Critical error;|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) | 80 +|Crown error |(% style="width:432px" %) connection with a Crown forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) | 81 +|Cell count error |(% style="width:432px" %) number of cells does not match the specified value;|(% style="width:190px" %) |(% style="width:183px" %) | 82 +|HYG offline |(% style="width:432px" %) connection with a HYG forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) | 83 +|Need acknowledge |(% style="width:432px" %) there is an unacknowledged error in Error journal;|(% style="width:190px" %) |(% style="width:183px" %) | 84 +|Combilift offline |(% style="width:432px" %) connection with a Combilift forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) | 85 +|Short circuit|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) | 86 +|High contactor temperature|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) | 87 +|ADC error |(% style="width:432px" %) current cannot be measured;|(% style="width:190px" %) |(% style="width:183px" %) | 88 +|Current sensor error |(% style="width:432px" %) error in the current sensor circuit;|(% style="width:190px" %) |(% style="width:183px" %) | 89 +|CH contactor cycles error |(% style="width:432px" %) switching frequency of the charging contactor is too high;|(% style="width:190px" %) |(% style="width:183px" %) | 90 +|DCH contactor cycles error |(% style="width:432px" %) switching frequency of the discharging contactor is too high;|(% style="width:190px" %) |(% style="width:183px" %) | 91 +|Shunt offline |(% style="width:432px" %) connection with the shunt current sensor is lost;|(% style="width:190px" %) |(% style="width:183px" %) | 92 +|Shunt error |(% style="width:432px" %) internal error of the shunt current sensor;|(% style="width:190px" %) |(% style="width:183px" %) | 93 +|WDT reset |(% style="width:432px" %) watchdog timer reset the device;|(% style="width:190px" %) |(% style="width:183px" %) | 94 +|No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:190px" %) |(% style="width:183px" %) | 95 +|Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:190px" %) |(% style="width:183px" %) | 96 +|Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) | 97 +|Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:190px" %)Low temperature protection|(% style="width:183px" %) | 98 +|High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:190px" %)High temperature protection|(% style="width:183px" %) | 99 +|Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:190px" %) |(% style="width:183px" %) | 100 +|Stuck contactor;|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) | 101 +|CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) | 102 +|DCH contactor feedback error |(% style="width:432px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) | 103 +|Insulation fault;|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) | 104 +|PCH contactor feedback error |(% style="width:432px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) | 105 +|CH/DCH contactor feedback error |(% style="width:432px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) | 106 +|Main contactor feedback error |(% style="width:432px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) | 107 +|General error|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) | 108 +|High voltage fault |(% style="width:432px" %) failure of high voltage measuring circuits;|(% style="width:190px" %) |(% style="width:183px" %) | 109 +|Power switch error |(% style="width:432px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:190px" %) |(% style="width:183px" %) | 110 +|HVIL error |(% style="width:432px" %) breakage of high-voltage interlock current loop;|(% style="width:190px" %) |(% style="width:183px" %) | 111 +|Precharge error |(% style="width:432px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:190px" %) |(% style="width:183px" %) | 112 +|Power fault |(% style="width:432px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:190px" %) |(% style="width:183px" %) | 113 +|Current limit error |(% style="width:432px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:190px" %) |(% style="width:183px" %) | 115 115 116 116