Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -69,12 +69,12 @@ 69 69 |Overcurrent|(% style="width:432px" %) |(% style="width:190px" %)Overcurrent protection|(% style="width:183px" %) | 70 70 |Undervoltage|(% style="width:432px" %) |(% style="width:190px" %)Undervoltage protection|(% style="width:183px" %) | 71 71 |Overvoltage|(% style="width:432px" %) |(% style="width:190px" %)Overvoltage protection|(% style="width:183px" %) | 72 -|Low temperature (DCH) |(% style="width:432px" %) temperature is too low for discharging;|(% style="width:190px" %) |(% style="width:183px" %) | 73 -|High temperature (DCH) |(% style="width:432px" %) temperature is too high for discharging;|(% style="width:190px" %) |(% style="width:183px" %) | 74 -|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:190px" %) |(% style="width:183px" %) | 75 -|High humidity |(% style="width:432px" %) humidity of the battery is increased;|(% style="width:190px" %) |(% style="width:183px" %) | 76 -|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:190px" %) |(% style="width:183px" %) | 77 -|High Logic temperature |(% style="width:432px" %) at least one of the Logic devices is overheated;|(% style="width:190px" %) |(% style="width:183px" %) | 72 +|Low temperature (DCH) |(% style="width:432px" %) temperature is too low for discharging;|(% style="width:190px" %)Low temperature protection|(% style="width:183px" %) | 73 +|High temperature (DCH) |(% style="width:432px" %) temperature is too high for discharging;|(% style="width:190px" %)High temperature protection|(% style="width:183px" %) | 74 +|Battery cover error |(% style="width:432px" %) battery cover is open;|(% style="width:190px" %)Battery cover protection|(% style="width:183px" %) | 75 +|High humidity |(% style="width:432px" %) humidity of the battery is increased;|(% style="width:190px" %)High humidity protection|(% style="width:183px" %) | 76 +|Water |(% style="width:432px" %) there is water in the battery enclosure;|(% style="width:190px" %)Water protection|(% style="width:183px" %) | 77 +|High Logic temperature |(% style="width:432px" %) at least one of the Logic devices is overheated;|(% style="width:190px" %)Logic h|(% style="width:183px" %) | 78 78 |Logic offline |(% style="width:432px" %) at least one of the Logic devices is offline;|(% style="width:190px" %) |(% style="width:183px" %) | 79 79 |Critical error;|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) | 80 80 |Crown error |(% style="width:432px" %) connection with a Crown forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) | ... ... @@ -94,8 +94,8 @@ 94 94 |No temperature sensors |(% style="width:432px" %) the device has no temperature sensors connected;|(% style="width:190px" %) |(% style="width:183px" %) | 95 95 |Temperature sensor is shorted |(% style="width:432px" %) some temperature sensors are shorted;|(% style="width:190px" %) |(% style="width:183px" %) | 96 96 |Spirit offline |(% style="width:432px" %) connection with a Spirit forklift is lost;|(% style="width:190px" %) |(% style="width:183px" %) | 97 -|Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:190px" %) |(% style="width:183px" %) | 98 -|High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:190px" %) |(% style="width:183px" %) | 97 +|Low temperature (CH) |(% style="width:432px" %) temperature is too low for charging;|(% style="width:190px" %)Low temperature protection|(% style="width:183px" %) | 98 +|High temperature (CH) |(% style="width:432px" %) temperature is too high for charging;|(% style="width:190px" %)High temperature protection|(% style="width:183px" %) | 99 99 |Unallowable charging |(% style="width:432px" %) charging the battery through the discharging contactor;|(% style="width:190px" %) |(% style="width:183px" %) | 100 100 |Stuck contactor;|(% style="width:432px" %) |(% style="width:190px" %) |(% style="width:183px" %) | 101 101 |CH contactor feedback error |(% style="width:432px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:190px" %) |(% style="width:183px" %) |