Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -48,25 +48,28 @@ 48 48 49 49 Here is the list of available input signals of BMS Main 3. 50 50 51 -|Name|Description|Where is used| | 52 -|Battery cover| | | | 53 -|Charger connected| | | | 54 -|Power up/down request| | | | 55 -|Inhibit charging| | | | 56 -|Inhibit discharging| | | | 57 -| | | | | 58 -| | | | | 59 -| | | | | 60 -| | | | | 61 -| | | | | 62 -| | | | | 63 -| | | | | 64 -| | | | | 65 -| | | | | 66 -| | | | | 67 -| | | | | 68 -| | | | | 69 -| | | | | 70 -| | | | | 51 +(% style="width:1227px" %) 52 +|**Name**|**Description**|(% style="width:370px" %)**Where is used**|(% style="width:160px" %) |(% style="width:111px" %) 53 +|No input | input is not used;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 54 +|Battery cover | a signal from the battery cover;|(% style="width:370px" %)Battery cover protection|(% style="width:160px" %) |(% style="width:111px" %) 55 +|Charger connected | a signal indicating that charger is connected;|(% style="width:370px" %)Charge controller, Discharge controller|(% style="width:160px" %) |(% style="width:111px" %) 56 +|Power up/down request | a request to power down the device;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 57 +|Inhibit charging | a command to open the charging contactor;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 58 +|Inhibit discharging | a command to open the discharging contactor;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 59 +|CH contactor feedback | a signal from charging contactor feedback loop;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 60 +|DCH contactor feedback | a signal from discharging contactor feedback loop;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 61 +|Insulation status | a signal from an insulation monitoring device;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 62 +|Charge request | a request to close the charging contactor;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 63 +|Precharge request | a request to close the precharging contactor;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 64 +|Discharge request | a request to close the discharging contactor;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 65 +|PCH contactor feedback | a signal from precharging contactor feedback loop;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 66 +|CH/DCH contactor feedback | a signal from charging/discharging contactor feedback loop;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 67 +|Main contactor feedback | a signal from main contactor feedback loop;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 68 +|Interlock | a signal from interlock loop;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 69 +|Fuse 1, Fuse 2, Fuse 3 | signals from fuses;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 70 +|Circuit breaker status | status of protection disconnector;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 71 +|Balancing request | a request to balance the cells;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 72 +|Close Main contactor | a request to close the main contactor;|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 73 +|Close External 1 | a request to close the External 1 discrete output (if assigned).|(% style="width:370px" %) |(% style="width:160px" %) |(% style="width:111px" %) 71 71 72 72