Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,7 +9,7 @@ 9 9 Here is the list of available input signals of BMS Main 3. 10 10 11 11 (% style="width:1227px" %) 12 -|(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)** Where isused**|(% colspan="3" rowspan="1" style="width:160px" %)**Settable via**12 +|(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Used by**|(% colspan="3" rowspan="1" style="width:160px" %)**Settable via** 13 13 |(% style="width:112px" %)**Discrete input**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus** 14 14 |(% style="width:216px" %)Battery cover |(% style="width:321px" %) a signal from the battery cover;|(% style="width:258px" %)Battery cover protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 15 15 |(% style="width:216px" %)Charger connected |(% style="width:321px" %) a signal indicating that charger is connected;|(% style="width:258px" %)Charge controller, Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %) ... ... @@ -36,7 +36,7 @@ 36 36 Here is the list of available internal states of BMS Main 3. 37 37 38 38 (% style="width:1227px" %) 39 -|(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Set up by**|(% rowspan="2" style="width:258px" %) |(% colspan="4" rowspan="1" style="width:258px" %)**Shared via** 39 +|(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Set up by**|(% rowspan="2" style="width:258px" %)**Used by**|(% colspan="4" rowspan="1" style="width:258px" %)**Shared via** 40 40 |(% style="width:163px" %)**Discrete output**|(% style="width:126px" %)**Switch**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus** 41 41 |Low SOC | a signal corresponding the low SOC of the battery;|(% style="width:258px" %)Low SOC signal controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 42 42 |High charging current | charging current is high;|(% style="width:258px" %)High charging signal controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %) ... ... @@ -54,8 +54,8 @@ 54 54 |Cooler | a command to turn on a cooler;|(% style="width:258px" %)Cooler controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 55 55 |Balancing 1 | balancing the first series of cells;|(% style="width:258px" %)Series balancing controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 56 56 |Balancing 2 | balancing the second series of cells;|(% style="width:258px" %)Series balancing controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 57 -|Ready to charge | the battery is ready to be charged;|(% style="width:258px" %)Charging status controller ,Charge controller, Charge/Discharge controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)•|(% style="width:159px" %)58 -|Ready to discharge | the battery is ready to be discharged;|(% style="width:258px" %)Discharging status controller ,Discharge controller, Charge/Discharge controller,|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %)57 +|Ready to charge | the battery is ready to be charged;|(% style="width:258px" %)Charging status controller|(% style="width:258px" %)Charge controller, Charge/Discharge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)•|(% style="width:159px" %) 58 +|Ready to discharge | the battery is ready to be discharged;|(% style="width:258px" %)Discharging status controller|(% style="width:258px" %)Discharge controller, Charge/Discharge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 59 59 |Power up | an indication of BMS power status;|(% style="width:258px" %) |(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 60 60 |General error | state of the configurable (general) error;|(% style="width:258px" %)General error protection|(% style="width:258px" %) |(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %) 61 61 |External 1 | a signal that activates by the remote request.|(% style="width:258px" %)External 1 input signal|(% style="width:258px" %) |(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %)