Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -36,10 +36,10 @@ 36 36 Here is the list of available internal states of BMS Main 3. 37 37 38 38 (% style="width:1227px" %) 39 -|(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)** Setupby**|(% rowspan="2" style="width:258px" %) |(% colspan="4" rowspan="1" style="width:258px" %)**Shared via**39 +|(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% colspan="1" rowspan="2" style="width:321px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Used by**|(% rowspan="2" style="width:258px" %)**Configurable in**|(% colspan="4" rowspan="1" style="width:258px" %)**Shared via** 40 40 |(% style="width:163px" %)**Discrete output**|(% style="width:126px" %)**Switch**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus** 41 -|Low SOC | a signal corresponding the low SOC of the battery;|(% style="width:258px" %) LowSOC signal controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)42 -|High charging current | charging current is high;|(% style="width:258px" %)High charging signal controller|(% style="width: 258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %)41 +|Low SOC | a signal corresponding the low SOC of the battery;|(% style="width:258px" %) |(% style="width:258px" %)Low SOC signal controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 42 +|High charging current | charging current is high;|(% style="width:258px" %) |(% style="width:258px" %)High charging signal controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %) 43 43 |Main contactor | state of the main contactor;|(% style="width:258px" %)Main contactor controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 44 44 |Charging | state of the charging contactor;|(% style="width:258px" %)Charge controller, Charge/Discharge controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 45 45 |Allow charging | a signal for a charger to start charging;|(% style="width:258px" %)Charge controller, Charge/Discharge controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) ... ... @@ -57,5 +57,5 @@ 57 57 |Ready to charge | the battery is ready to be charged;|(% style="width:258px" %)Charging status controller, Charge controller, Charge/Discharge controller|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)•|(% style="width:159px" %) 58 58 |Ready to discharge | the battery is ready to be discharged;|(% style="width:258px" %)Discharging status controller, Discharge controller, Charge/Discharge controller, |(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %) 59 59 |Power up | an indication of BMS power status;|(% style="width:258px" %) |(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %) 60 -|General error | state of the configurable (general) error;|(% style="width:258px" %)General error protection|(% style="width:258px" %) |(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %)61 -|External 1 | a signal that activates by the remote request.|(% style="width:258px" %) External1 input signal|(% style="width:258px" %) |(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %)60 +|General error | state of the configurable (general) error;|(% style="width:258px" %)General error|(% style="width:258px" %) |(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %) 61 +|External 1 | a signal that activates by the remote request.|(% style="width:258px" %) |(% style="width:258px" %) |(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %)