... ... @@ -41,21 +41,21 @@
41 41  |Low SOC | a signal corresponding the low SOC of the battery;|(% style="width:258px" %)Low SOC signal controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
42 42  |High charging current | charging current is high;|(% style="width:258px" %)High charging signal controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %)
43 43  |Main contactor | state of the main contactor;|(% style="width:258px" %)Main contactor controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
44 -|Charging | state of the charging contactor;|(% style="width:258px" %)Charge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
45 -|Allow charging | a signal for a charger to start charging;|(% style="width:258px" %)Charge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
44 +|Charging | state of the charging contactor;|(% style="width:258px" %)Charge controller, Charging/Discharging controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
45 +|Allow charging | a signal for a charger to start charging;|(% style="width:258px" %)Charge controller, Charging/Discharging controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
46 46  |Charging current present | the presence of the charging current;|(% style="width:258px" %)Charging status controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
47 47  |Precharging | state of the precharging contactor;|(% style="width:258px" %)Precharge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
48 -|Discharging | state of the discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
48 +|Discharging | state of the discharging contactor;|(% style="width:258px" %)Discharge controller, Charge/Discharge controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
49 49  |Discharging current present | the presence of the discharging current;|(% style="width:258px" %)Discharging status controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %)
50 50  |Discharging (AUX) | state of the auxiliary discharging contactor;|(% style="width:258px" %)Discharging (AUX) controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %)
51 51  |Power down ACK | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:258px" %)Power down controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
52 -|Charging/discharging - state of the charging/discharging contactor;| |(% style="width:258px" %)Contactor feedback protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
53 -|Heater | a command to turn on a heater;|(% style="width:258px" %)Contactor feedback protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
54 -|Cooler | a command to turn on a cooler;|(% style="width:258px" %)Interlock protection|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
55 -|Balancing 1 | balancing the first series of cells;|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
56 -|Balancing 2 | balancing the second series of cells;|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
57 -|Ready to charge | the battery is ready to be charged;|(% style="width:258px" %)Cell balance|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)•|(% style="width:159px" %)
58 -|Ready to discharge | the battery is ready to be discharged;|(% style="width:258px" %)Main contactor|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %)
52 +|Charging/discharging|state of the charging/discharging contactor;|(% style="width:258px" %)Charging/Discharging controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
53 +|Heater | a command to turn on a heater;|(% style="width:258px" %)Heater controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
54 +|Cooler | a command to turn on a cooler;|(% style="width:258px" %)Cooler controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
55 +|Balancing 1 | balancing the first series of cells;|(% style="width:258px" %)Series balancing controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
56 +|Balancing 2 | balancing the second series of cells;|(% style="width:258px" %)Series balancing controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
57 +|Ready to charge | the battery is ready to be charged;|(% style="width:258px" %)Charging status controller, Charge controller, Charging/Discharging controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)•|(% style="width:159px" %)
58 +|Ready to discharge | the battery is ready to be discharged;|(% style="width:258px" %)Discharging status controller|(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %)
59 59  |Power up | an indication of BMS power status;|(% style="width:258px" %) |(% style="width:163px" %)•|(% style="width:126px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
60 -|General error | state of the configurable (general) error;|(% style="width:258px" %) |(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %)
60 +|General error | state of the configurable (general) error;|(% style="width:258px" %)General error|(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %)
61 61  |External 1 | a signal that activates by the remote request.|(% style="width:258px" %) |(% style="width:163px" %) |(% style="width:126px" %) |(% style="width:159px" %) |(% style="width:159px" %)